Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing

IF 2.2 4区 医学 Q3 HEMATOLOGY
Christopher Reilly-Stitt, Ian Jennings, Steve Kitchen, Michael Cahillane, Christine Saunders, Chloe George, Tom Scorer, Isobel D. Walker
{"title":"Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing","authors":"Christopher Reilly-Stitt,&nbsp;Ian Jennings,&nbsp;Steve Kitchen,&nbsp;Michael Cahillane,&nbsp;Christine Saunders,&nbsp;Chloe George,&nbsp;Tom Scorer,&nbsp;Isobel D. Walker","doi":"10.1111/ijlh.14445","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>To achieve accreditation for ISO 15189, laboratories are required to either participate in EQA exercises or intra-laboratory comparisons to meet the standard. Light transmission aggregometry performed by laboratory scientists for the clinical investigation of possible platelet function defects is time dependent. Current EQA available audits the interpretation of platelet aggregation traces.</p>\n </section>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>Could NEQAS BC provide external quality assessment (EQA) material to centres employing Light Transmission Aggregometry LTA for clinical investigation of platelet function? The use of fresh donor platelets could audit more of the analytical and post analytical aspects of light transmission aggregation than currently available.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A pool of donor platelets was split into aliquots that were distributed to testing centres across England, Scotland and Wales for testing within a 72 h window. Participating centres employed their locally validated testing methods for LTA assays, for agonists including ADP; Arachidonic acid; Collagen; Epinephrine; Ristocetin; TRAP and U46619.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Five different aggregation platforms were used including: Chronolog 700; Helena Aggram; PAP-8; Stago TA-8V and Sysmex CN-series. Sample packs were tested through the 72 h window with most sites performing LTA on the EQA material on day one of the three.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The % consensus of interpretations provided by participants for agonists including: ADP; Arachidonic acid; Collagen; Epinephrine and Ristocetin ranged from 94% to 100% indicating that the material is stable plus centres using different aggregometers returned the same clinical interpretations.</p>\n </section>\n </div>","PeriodicalId":14120,"journal":{"name":"International Journal of Laboratory Hematology","volume":"47 3","pages":"529-535"},"PeriodicalIF":2.2000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Laboratory Hematology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14445","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

To achieve accreditation for ISO 15189, laboratories are required to either participate in EQA exercises or intra-laboratory comparisons to meet the standard. Light transmission aggregometry performed by laboratory scientists for the clinical investigation of possible platelet function defects is time dependent. Current EQA available audits the interpretation of platelet aggregation traces.

Objectives

Could NEQAS BC provide external quality assessment (EQA) material to centres employing Light Transmission Aggregometry LTA for clinical investigation of platelet function? The use of fresh donor platelets could audit more of the analytical and post analytical aspects of light transmission aggregation than currently available.

Methods

A pool of donor platelets was split into aliquots that were distributed to testing centres across England, Scotland and Wales for testing within a 72 h window. Participating centres employed their locally validated testing methods for LTA assays, for agonists including ADP; Arachidonic acid; Collagen; Epinephrine; Ristocetin; TRAP and U46619.

Results

Five different aggregation platforms were used including: Chronolog 700; Helena Aggram; PAP-8; Stago TA-8V and Sysmex CN-series. Sample packs were tested through the 72 h window with most sites performing LTA on the EQA material on day one of the three.

Conclusion

The % consensus of interpretations provided by participants for agonists including: ADP; Arachidonic acid; Collagen; Epinephrine and Ristocetin ranged from 94% to 100% indicating that the material is stable plus centres using different aggregometers returned the same clinical interpretations.

冷藏血小板:血小板聚集外部质量评估/能力测试的解决方案。
背景:为了获得ISO 15189的认可,实验室需要参加EQA练习或实验室内部比较以达到标准。由实验室科学家进行的临床研究可能的血小板功能缺陷的光透射聚集是时间依赖的。目前EQA可以审计血小板聚集痕迹的解释。目的:NEQAS BC能否为采用光透射聚集法LTA的中心提供用于血小板功能临床研究的外部质量评价(EQA)材料?与目前相比,使用新鲜的供体血小板可以对光透射聚集的分析和分析后方面进行更多的审计。方法:将供体血小板池分成等份,分发到英格兰、苏格兰和威尔士的检测中心,在72小时内进行检测。参与中心采用当地验证的LTA检测方法,用于激动剂包括ADP;花生四烯酸;胶原蛋白;肾上腺素;瑞斯西丁素;TRAP和U46619。结果:使用了5种不同的聚合平台,包括:Chronolog 700;海伦娜Aggram;PAP-8;Stago TA-8V和Sysmex cn系列。样品包通过72小时窗口进行测试,大多数站点在三天的第一天对EQA材料进行LTA。结论:参与者提供的激动剂解释的一致性百分比包括:ADP;花生四烯酸;胶原蛋白;肾上腺素和瑞斯托素的范围从94%到100%,表明材料是稳定的,而且使用不同聚集计的中心返回相同的临床解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.50
自引率
6.70%
发文量
211
审稿时长
6-12 weeks
期刊介绍: The International Journal of Laboratory Hematology provides a forum for the communication of new developments, research topics and the practice of laboratory haematology. The journal publishes invited reviews, full length original articles, and correspondence. The International Journal of Laboratory Hematology is the official journal of the International Society for Laboratory Hematology, which addresses the following sub-disciplines: cellular analysis, flow cytometry, haemostasis and thrombosis, molecular diagnostics, haematology informatics, haemoglobinopathies, point of care testing, standards and guidelines. The journal was launched in 2006 as the successor to Clinical and Laboratory Hematology, which was first published in 1979. An active and positive editorial policy ensures that work of a high scientific standard is reported, in order to bridge the gap between practical and academic aspects of laboratory haematology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信