Optimizing CT Imaging Parameters: Implications for Diagnostic Accuracy in Nuclear Medicine.

IF 4.6 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Anders F S Mikkelsen, Jesper Thygesen, Joan Fledelius
{"title":"Optimizing CT Imaging Parameters: Implications for Diagnostic Accuracy in Nuclear Medicine.","authors":"Anders F S Mikkelsen, Jesper Thygesen, Joan Fledelius","doi":"10.1053/j.semnuclmed.2025.02.008","DOIUrl":null,"url":null,"abstract":"<p><p>X-ray computed tomography (CT) is an important companion modality in molecular imaging, offering attenuation correction (AC) of single-photon emission computed tomography (SPECT) - and positron emission tomography (PET)-data, topographic information in scans as well as changes in morphology in serial follow-up studies. Image quality plays a critical role in delivering an acceptable diagnosis and in medical treatment planning. Variability in protocols can present a considerable challenge in achieving consistent image quality within departments. The differences in CT scanning protocol metrics established by various manufacturers and across different generations of scanners can contribute to this issue, making the standardization of image quality a complex task. This review aims to present relevant literature herein and provide an introduction of the CT imaging parameters, including acquisition factors, reconstruction algorithms, and relevant image quality metrics, and discuss possible ways to implement a robust CT protocol review process in a nuclear medicine department. We also evaluate the potential of iterative reconstruction (IR) and deep learning (DL) for enhancing image quality and minimizing exposure doses. This article points to the need for periodic audit of image quality to guarantee that CT protocols are suited for the intended purpose. Through the creation of local diagnostic reference levels and monitoring performance through protocol management, physicians may aim at delivering high quality imaging services consistently adhering to the principles of ALARA and reduction of dose for both patients and workers.</p>","PeriodicalId":21643,"journal":{"name":"Seminars in nuclear medicine","volume":" ","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in nuclear medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1053/j.semnuclmed.2025.02.008","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

X-ray computed tomography (CT) is an important companion modality in molecular imaging, offering attenuation correction (AC) of single-photon emission computed tomography (SPECT) - and positron emission tomography (PET)-data, topographic information in scans as well as changes in morphology in serial follow-up studies. Image quality plays a critical role in delivering an acceptable diagnosis and in medical treatment planning. Variability in protocols can present a considerable challenge in achieving consistent image quality within departments. The differences in CT scanning protocol metrics established by various manufacturers and across different generations of scanners can contribute to this issue, making the standardization of image quality a complex task. This review aims to present relevant literature herein and provide an introduction of the CT imaging parameters, including acquisition factors, reconstruction algorithms, and relevant image quality metrics, and discuss possible ways to implement a robust CT protocol review process in a nuclear medicine department. We also evaluate the potential of iterative reconstruction (IR) and deep learning (DL) for enhancing image quality and minimizing exposure doses. This article points to the need for periodic audit of image quality to guarantee that CT protocols are suited for the intended purpose. Through the creation of local diagnostic reference levels and monitoring performance through protocol management, physicians may aim at delivering high quality imaging services consistently adhering to the principles of ALARA and reduction of dose for both patients and workers.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Seminars in nuclear medicine
Seminars in nuclear medicine 医学-核医学
CiteScore
9.80
自引率
6.10%
发文量
86
审稿时长
14 days
期刊介绍: Seminars in Nuclear Medicine is the leading review journal in nuclear medicine. Each issue brings you expert reviews and commentary on a single topic as selected by the Editors. The journal contains extensive coverage of the field of nuclear medicine, including PET, SPECT, and other molecular imaging studies, and related imaging studies. Full-color illustrations are used throughout to highlight important findings. Seminars is included in PubMed/Medline, Thomson/ISI, and other major scientific indexes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信