Detection of the initial gap at different implant-abutment connections.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Eduardo Anitua, Ricardo Tejero, Mikel Armentia, Iker Fernández-de-Gobeo, Luis Saracho
{"title":"Detection of the initial gap at different implant-abutment connections.","authors":"Eduardo Anitua, Ricardo Tejero, Mikel Armentia, Iker Fernández-de-Gobeo, Luis Saracho","doi":"10.1016/j.prosdent.2025.02.013","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases. An accurate determination of the first IAC gap under realistic dynamic-loading conditions is needed to investigate current and future IAC designs.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to use a novel method of determining the load and probability of occurrence of the elastic first IAC gap that overcomes most of the limitations of the representative IACs currently available.</p><p><strong>Material and methods: </strong>Three flat-straight and 4 conical-tapered connections with varying abutment cone angles with 8 specimens per configuration (n=8) were tested with an in situ loading experiment underwater by following the International Organization for Standardization (ISO) 14801 standard. Before load application, the IACs were filled with toluidine, and the screws tightened to 35 Ncm. Incremental loading of 20 N was applied over 1000 cycles until leakage was detected by a video recording macro-equipped camera. Differences between the means were determined by 1-way ANOVA (α=.05). The probability of gap occurrence was calculated from the data obtained based on the maximum occlusal force values reported in literature.</p><p><strong>Results: </strong>The method allowed the detection of the first IAC gap in the elastic regime. Flat connections showed a linear relationship between connection diameter and the first gap load ranging from 140.0 ±21.4 N (Ø3.0 mm) to 255.0 ±31.6 N (Ø4.1 mm). On Ø3.5 mm connections, the gap at flat connections opened at 193.8 ±22.0 N, while, at conical connections, the loads needed were significantly lower and the dispersion higher, irrespective of the angle between the abutment and the implant connection cones: 135.0 ±80.5 N (0 degrees), 100.0 ±54.5 N (0.4 degrees, P<.05), 77.5 ±37.7 N (0.8 degrees, P<.05) and 82.5 ±49.5 N (1.2 degrees, P<.05). Consequently, conical connections had a higher probability of gaps, particularly in the posterior zone, ranging from 8.2% to 29.0% of the reported mastication force.</p><p><strong>Conclusions: </strong>This innovative in situ leakage detection method enabled the identification of disparities in the masticatory load at which initial gaps occurred across various flat and conical IAC configurations.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.02.013","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases. An accurate determination of the first IAC gap under realistic dynamic-loading conditions is needed to investigate current and future IAC designs.

Purpose: The purpose of this in vitro study was to use a novel method of determining the load and probability of occurrence of the elastic first IAC gap that overcomes most of the limitations of the representative IACs currently available.

Material and methods: Three flat-straight and 4 conical-tapered connections with varying abutment cone angles with 8 specimens per configuration (n=8) were tested with an in situ loading experiment underwater by following the International Organization for Standardization (ISO) 14801 standard. Before load application, the IACs were filled with toluidine, and the screws tightened to 35 Ncm. Incremental loading of 20 N was applied over 1000 cycles until leakage was detected by a video recording macro-equipped camera. Differences between the means were determined by 1-way ANOVA (α=.05). The probability of gap occurrence was calculated from the data obtained based on the maximum occlusal force values reported in literature.

Results: The method allowed the detection of the first IAC gap in the elastic regime. Flat connections showed a linear relationship between connection diameter and the first gap load ranging from 140.0 ±21.4 N (Ø3.0 mm) to 255.0 ±31.6 N (Ø4.1 mm). On Ø3.5 mm connections, the gap at flat connections opened at 193.8 ±22.0 N, while, at conical connections, the loads needed were significantly lower and the dispersion higher, irrespective of the angle between the abutment and the implant connection cones: 135.0 ±80.5 N (0 degrees), 100.0 ±54.5 N (0.4 degrees, P<.05), 77.5 ±37.7 N (0.8 degrees, P<.05) and 82.5 ±49.5 N (1.2 degrees, P<.05). Consequently, conical connections had a higher probability of gaps, particularly in the posterior zone, ranging from 8.2% to 29.0% of the reported mastication force.

Conclusions: This innovative in situ leakage detection method enabled the identification of disparities in the masticatory load at which initial gaps occurred across various flat and conical IAC configurations.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信