Morten Aa Petersen, Hugo Vachon, Johannes M Giesinger, Mogens Groenvold
{"title":"Using prior information to individualize start item selection when assessing physical functioning with the EORTC CAT Core.","authors":"Morten Aa Petersen, Hugo Vachon, Johannes M Giesinger, Mogens Groenvold","doi":"10.1186/s12955-025-02353-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Computerized adaptive test (CAT) provides individualized measurement, using the patient's previous responses to select the next most informative item. However, the first item, the start item, is usually not individualized as no score estimate is available a priori. The European Organisation for Research and Treatment of Cancer (EORTC) CAT Core covers 15 health-related quality of life domains. Scores for one domain may be used to obtain initial score estimates for another domain. We assessed the potential for using such cross-domain information to individualize start item selection for the EORTC CAT Core physical functioning.</p><p><strong>Methods: </strong>The potential for predicting physical functioning (PF) scores from each of the 14 other domains using linear regression was assessed in an international, mixed sample comprising 10,084 cancer patient assessments. Using Monte Carlo CAT simulations, the impact of individually selected PF start items vs. fixed start item for CAT measurement precision was assessed.</p><p><strong>Results: </strong>Depending on the domain predicting PF, the correlation of predicted and observed PF scores ranged 0.25-0.71 and the predicted PF scores were within 1SD of the observed PF scores for 57-85% of the patients. The CAT simulations showed that individually selected start items improved measurement precision for the initial steps of CATs. The application of individual start items had trivial or no impact on measurement precision when the CAT asked three or more items.</p><p><strong>Conclusions: </strong>Simple linear regression may provide useful cross-domain predictions. Using individualized start items may increase measurement precision of the EORTC CAT Core for the initial steps of CAT which may be of relevance for short CATs.</p>","PeriodicalId":12980,"journal":{"name":"Health and Quality of Life Outcomes","volume":"23 1","pages":"21"},"PeriodicalIF":3.2000,"publicationDate":"2025-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11892134/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health and Quality of Life Outcomes","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12955-025-02353-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Computerized adaptive test (CAT) provides individualized measurement, using the patient's previous responses to select the next most informative item. However, the first item, the start item, is usually not individualized as no score estimate is available a priori. The European Organisation for Research and Treatment of Cancer (EORTC) CAT Core covers 15 health-related quality of life domains. Scores for one domain may be used to obtain initial score estimates for another domain. We assessed the potential for using such cross-domain information to individualize start item selection for the EORTC CAT Core physical functioning.
Methods: The potential for predicting physical functioning (PF) scores from each of the 14 other domains using linear regression was assessed in an international, mixed sample comprising 10,084 cancer patient assessments. Using Monte Carlo CAT simulations, the impact of individually selected PF start items vs. fixed start item for CAT measurement precision was assessed.
Results: Depending on the domain predicting PF, the correlation of predicted and observed PF scores ranged 0.25-0.71 and the predicted PF scores were within 1SD of the observed PF scores for 57-85% of the patients. The CAT simulations showed that individually selected start items improved measurement precision for the initial steps of CATs. The application of individual start items had trivial or no impact on measurement precision when the CAT asked three or more items.
Conclusions: Simple linear regression may provide useful cross-domain predictions. Using individualized start items may increase measurement precision of the EORTC CAT Core for the initial steps of CAT which may be of relevance for short CATs.
期刊介绍:
Health and Quality of Life Outcomes is an open access, peer-reviewed, journal offering high quality articles, rapid publication and wide diffusion in the public domain.
Health and Quality of Life Outcomes considers original manuscripts on the Health-Related Quality of Life (HRQOL) assessment for evaluation of medical and psychosocial interventions. It also considers approaches and studies on psychometric properties of HRQOL and patient reported outcome measures, including cultural validation of instruments if they provide information about the impact of interventions. The journal publishes study protocols and reviews summarising the present state of knowledge concerning a particular aspect of HRQOL and patient reported outcome measures. Reviews should generally follow systematic review methodology. Comments on articles and letters to the editor are welcome.