Heterogeneity of ventricular action potentials in neonatal rat cardiomyocytes and methodological aspects of patch clamp measurements.

IF 3.2 3区 医学 Q2 PHYSIOLOGY
Frontiers in Physiology Pub Date : 2025-02-21 eCollection Date: 2025-01-01 DOI:10.3389/fphys.2025.1537345
Pascal Syren, Anna Zlatopolskaia, Claus Bruehl, Axel Schöffel, Teresa Caspari, Chiara Heß, Norbert Frey, Dierk Thomas, Patrick Lugenbiel
{"title":"Heterogeneity of ventricular action potentials in neonatal rat cardiomyocytes and methodological aspects of patch clamp measurements.","authors":"Pascal Syren, Anna Zlatopolskaia, Claus Bruehl, Axel Schöffel, Teresa Caspari, Chiara Heß, Norbert Frey, Dierk Thomas, Patrick Lugenbiel","doi":"10.3389/fphys.2025.1537345","DOIUrl":null,"url":null,"abstract":"<p><p>Measurement of the ventricular action potential (AP) via whole-cell patch clamp is an important contributor to cardiac electrophysiological research. Neonatal rat ventricular cardiomyocytes (NRVCM) are a commonly used model, in particular for stressor- or drug-related questions. High variability of APs and individual methodological settings hinder comparison both in individual studies and, to an even greater degree, between different projects. This study aims to describe sources of AP heterogeneity in NRVCM related to patch clamp measurement with a focus on resolvable causes. Therefore, AP of NRVCM were induced in whole-cell configuration and measured in current-clamp mode. The effects of varying setup temperature, electrode resistance, resting- (RMP), respectively holding membrane potential (HMP), induction approach, current pulse duration and amplitude plus total assay duration were studied and compared to systematically analyzed literature. We analyzed the impact on different output parameters, namely, maximal upstroke velocity (dV/dt), maximal AP amplitude (APA) and AP duration at different percentages (XX%) of repolarization, APD<sub>XX</sub>. In a comparative literature research, we found that mean APD<sub>90</sub> in between 27.0 and 560.7 ms (own data 59.7 ± 5.8 ms) were described, with high variability and likely non-Gaussian distribution. In this study, APD<sub>90</sub>, APD<sub>50</sub> and APD<sub>30</sub>, are decreased at more negative RMP (respectively HMP) values. E.g., APD<sub>90</sub> is shortened by ∼60% after lowering HMP from -70 mV to -90 mV) while dV/dt and APA are increased at a more negative HMP. Pulse duration in induction did not affect main AP parameters itself, but induction energy levels above 1.5-fold the threshold energy level increased APA, while APD<sub>50</sub> and APD<sub>90</sub> were shortened. During series of APs at 1 Hz, spike duration (APD<sub>90</sub>) decreased by ∼27%, with stable AP after the third repetitive AP. Spike duration did also decreased by ∼40% after prolongated measurements for 21 min, indicating degradation of electrophysiological properties. To improve data quality in NRVCM-APs, we suggest using a constant HMP, adjustment of current pulse amplitude to the individual cells' threshold and the use of repetitive AP-inductions. Finally, we suggest the use of nonparametric statistical methods for statistical analysis. These aspects could reduce variability and lead to more reliable and comparable data.</p>","PeriodicalId":12477,"journal":{"name":"Frontiers in Physiology","volume":"16 ","pages":"1537345"},"PeriodicalIF":3.2000,"publicationDate":"2025-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11885515/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/fphys.2025.1537345","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Measurement of the ventricular action potential (AP) via whole-cell patch clamp is an important contributor to cardiac electrophysiological research. Neonatal rat ventricular cardiomyocytes (NRVCM) are a commonly used model, in particular for stressor- or drug-related questions. High variability of APs and individual methodological settings hinder comparison both in individual studies and, to an even greater degree, between different projects. This study aims to describe sources of AP heterogeneity in NRVCM related to patch clamp measurement with a focus on resolvable causes. Therefore, AP of NRVCM were induced in whole-cell configuration and measured in current-clamp mode. The effects of varying setup temperature, electrode resistance, resting- (RMP), respectively holding membrane potential (HMP), induction approach, current pulse duration and amplitude plus total assay duration were studied and compared to systematically analyzed literature. We analyzed the impact on different output parameters, namely, maximal upstroke velocity (dV/dt), maximal AP amplitude (APA) and AP duration at different percentages (XX%) of repolarization, APDXX. In a comparative literature research, we found that mean APD90 in between 27.0 and 560.7 ms (own data 59.7 ± 5.8 ms) were described, with high variability and likely non-Gaussian distribution. In this study, APD90, APD50 and APD30, are decreased at more negative RMP (respectively HMP) values. E.g., APD90 is shortened by ∼60% after lowering HMP from -70 mV to -90 mV) while dV/dt and APA are increased at a more negative HMP. Pulse duration in induction did not affect main AP parameters itself, but induction energy levels above 1.5-fold the threshold energy level increased APA, while APD50 and APD90 were shortened. During series of APs at 1 Hz, spike duration (APD90) decreased by ∼27%, with stable AP after the third repetitive AP. Spike duration did also decreased by ∼40% after prolongated measurements for 21 min, indicating degradation of electrophysiological properties. To improve data quality in NRVCM-APs, we suggest using a constant HMP, adjustment of current pulse amplitude to the individual cells' threshold and the use of repetitive AP-inductions. Finally, we suggest the use of nonparametric statistical methods for statistical analysis. These aspects could reduce variability and lead to more reliable and comparable data.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
5.00%
发文量
2608
审稿时长
14 weeks
期刊介绍: Frontiers in Physiology is a leading journal in its field, publishing rigorously peer-reviewed research on the physiology of living systems, from the subcellular and molecular domains to the intact organism, and its interaction with the environment. Field Chief Editor George E. Billman at the Ohio State University Columbus is supported by an outstanding Editorial Board of international researchers. This multidisciplinary open-access journal is at the forefront of disseminating and communicating scientific knowledge and impactful discoveries to researchers, academics, clinicians and the public worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信