A case of systemic contact dermatitis associated with a peritoneal dialysis catheter and treated with dupilumab.

IF 1 Q4 UROLOGY & NEPHROLOGY
Kosuke Mochizuki, Jun Takeoka, Naohiro Toda, Kansei Otsuka, Ryo Sato, Satoshi Kurahashi, Kyoka Fujita, Hisako Hirashima, Akira Ishii, Toshiyuki Komiya
{"title":"A case of systemic contact dermatitis associated with a peritoneal dialysis catheter and treated with dupilumab.","authors":"Kosuke Mochizuki, Jun Takeoka, Naohiro Toda, Kansei Otsuka, Ryo Sato, Satoshi Kurahashi, Kyoka Fujita, Hisako Hirashima, Akira Ishii, Toshiyuki Komiya","doi":"10.1007/s13730-025-00980-9","DOIUrl":null,"url":null,"abstract":"<p><p>Eosinophilia during the induction of peritoneal dialysis (PD) is frequently caused by icodextrin, but allergic reactions to PD catheters have been rarely reported. In previous reports, PD catheter-induced systemic contact dermatitis in patients undergoing PD sometimes required catheter removal, therefore there is a need to consider alternative renal replacement therapies other than PD. Here, we report a case of systemic contact dermatitis associated with a PD catheter that was successfully treated with dupilumab, avoiding catheter removal. The 62-year-old man undergoing PD had eosinophilia and pruritic skin rash after PD catheter implantation and was diagnosed with systemic contact dermatitis triggered by silicon contained in the catheter. Even though low doses of steroids were introduced, skin symptoms and eosinophilia were not controlled. After initiation of dupilumab treatment, skin pruritus was improved, and eosinophils also decreased. Although dupilumab use is expanding for systemic contact dermatitis, no previous reports of dupilumab administration in dialysis patients have been reported. This case is the first of a patient undergoing PD and using dupilumab for systemic contact dermatitis caused by a PD catheter, in which dupilumab successfully controlled skin rash and pruritus eosinophilia. Dupilumab is, therefore, a favorable option for treating systemic contact dermatitis induced by a PD catheter as an alternative to steroids and removal of the PD catheter.</p>","PeriodicalId":9697,"journal":{"name":"CEN Case Reports","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2025-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CEN Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13730-025-00980-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Eosinophilia during the induction of peritoneal dialysis (PD) is frequently caused by icodextrin, but allergic reactions to PD catheters have been rarely reported. In previous reports, PD catheter-induced systemic contact dermatitis in patients undergoing PD sometimes required catheter removal, therefore there is a need to consider alternative renal replacement therapies other than PD. Here, we report a case of systemic contact dermatitis associated with a PD catheter that was successfully treated with dupilumab, avoiding catheter removal. The 62-year-old man undergoing PD had eosinophilia and pruritic skin rash after PD catheter implantation and was diagnosed with systemic contact dermatitis triggered by silicon contained in the catheter. Even though low doses of steroids were introduced, skin symptoms and eosinophilia were not controlled. After initiation of dupilumab treatment, skin pruritus was improved, and eosinophils also decreased. Although dupilumab use is expanding for systemic contact dermatitis, no previous reports of dupilumab administration in dialysis patients have been reported. This case is the first of a patient undergoing PD and using dupilumab for systemic contact dermatitis caused by a PD catheter, in which dupilumab successfully controlled skin rash and pruritus eosinophilia. Dupilumab is, therefore, a favorable option for treating systemic contact dermatitis induced by a PD catheter as an alternative to steroids and removal of the PD catheter.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CEN Case Reports
CEN Case Reports UROLOGY & NEPHROLOGY-
CiteScore
1.90
自引率
0.00%
发文量
80
期刊介绍: Clinical and Experimental Nephrology (CEN) Case Reports is a peer-reviewed online-only journal, officially published biannually by the Japanese Society of Nephrology (JSN).  The journal publishes original case reports in nephrology and related areas.  The purpose of CEN Case Reports is to provide clinicians and researchers with a forum in which to disseminate their personal experience to a wide readership and to review interesting cases encountered by colleagues all over the world, from whom contributions are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信