Portable Fluorescence Microarray Reader-Enabled Biomarker Panel Detection System for Point-of-Care Diagnosis of Lupus Nephritis.

IF 3 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL
Micromachines Pub Date : 2025-01-29 DOI:10.3390/mi16020156
Aygun Teymur, Iftak Hussain, Chenling Tang, Ramesh Saxena, David Erickson, Tianfu Wu
{"title":"Portable Fluorescence Microarray Reader-Enabled Biomarker Panel Detection System for Point-of-Care Diagnosis of Lupus Nephritis.","authors":"Aygun Teymur, Iftak Hussain, Chenling Tang, Ramesh Saxena, David Erickson, Tianfu Wu","doi":"10.3390/mi16020156","DOIUrl":null,"url":null,"abstract":"<p><p>Point-of-care (POC) testing has revolutionized diagnostics by providing rapid, accessible solutions outside traditional laboratory settings. However, many POC systems lack the sensitivity or multiplexing capability required for complex diseases. This study introduces an LED-based fluorescence reader designed for POC applications, enabling multiplex detection of lupus nephritis (LN) biomarkers using a biomarker microarray (BMA) slide. The reader integrates an LED excitation source, neutral density (ND) filters for precise intensity control, and onboard image processing with Gaussian smoothing and centroid thresholding to enhance signal detection and localization. Five LN biomarkers (VSIG4, OPN, VCAM1, ALCAM, and TNFRSF1B) were assessed, and performance was validated against a Genepix laser-based scanner. The LED reader demonstrated strong correlation coefficients (r = 0.96-0.98) with the Genepix system for both standard curves and patient samples, achieving robust signal-to-noise ratios and reproducibility across all biomarkers. The multiplex format reduced sample volume and allowed simultaneous analysis of multiple biomarkers. These results highlight the reader's potential to bridge the gap between laboratory-grade precision and POC accessibility. By combining portability, cost-effectiveness, and high analytical performance, this fluorescence reader provides a practical solution for POC diagnostics, particularly in resource-limited settings, improving the feasibility of routine monitoring and early intervention for diseases requiring comprehensive biomarker analysis.</p>","PeriodicalId":18508,"journal":{"name":"Micromachines","volume":"16 2","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11857597/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micromachines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/mi16020156","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Point-of-care (POC) testing has revolutionized diagnostics by providing rapid, accessible solutions outside traditional laboratory settings. However, many POC systems lack the sensitivity or multiplexing capability required for complex diseases. This study introduces an LED-based fluorescence reader designed for POC applications, enabling multiplex detection of lupus nephritis (LN) biomarkers using a biomarker microarray (BMA) slide. The reader integrates an LED excitation source, neutral density (ND) filters for precise intensity control, and onboard image processing with Gaussian smoothing and centroid thresholding to enhance signal detection and localization. Five LN biomarkers (VSIG4, OPN, VCAM1, ALCAM, and TNFRSF1B) were assessed, and performance was validated against a Genepix laser-based scanner. The LED reader demonstrated strong correlation coefficients (r = 0.96-0.98) with the Genepix system for both standard curves and patient samples, achieving robust signal-to-noise ratios and reproducibility across all biomarkers. The multiplex format reduced sample volume and allowed simultaneous analysis of multiple biomarkers. These results highlight the reader's potential to bridge the gap between laboratory-grade precision and POC accessibility. By combining portability, cost-effectiveness, and high analytical performance, this fluorescence reader provides a practical solution for POC diagnostics, particularly in resource-limited settings, improving the feasibility of routine monitoring and early intervention for diseases requiring comprehensive biomarker analysis.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Micromachines
Micromachines NANOSCIENCE & NANOTECHNOLOGY-INSTRUMENTS & INSTRUMENTATION
CiteScore
5.20
自引率
14.70%
发文量
1862
审稿时长
16.31 days
期刊介绍: Micromachines (ISSN 2072-666X) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to micro-scaled machines and micromachinery. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信