Primary implant stability of two implant macro-designs in different alveolar ridge morphologies: an in vitro study.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Anna Jenner, Gabriela P Sabatini, Samir Abou-Ayash, Emilio Couso-Queiruga, Vivianne Chappuis, Clemens Raabe
{"title":"Primary implant stability of two implant macro-designs in different alveolar ridge morphologies: an in vitro study.","authors":"Anna Jenner, Gabriela P Sabatini, Samir Abou-Ayash, Emilio Couso-Queiruga, Vivianne Chappuis, Clemens Raabe","doi":"10.1186/s40729-025-00605-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The primary aim of this in vitro study was to investigate the primary implant stability obtained in immediate and late implant placement scenarios. Secondary aims evaluated the effect of two distinct implant macro-designs and examined the correlation between resonance frequency analysis (RFA) and final insertion torque.</p><p><strong>Methods: </strong>Partially edentulous maxillary models including six single sites simulating extraction sockets and healed alveolar ridges were used. Virtual implant planning facilitated static computer-assisted implant placement of bone level implants with either a shallow-threaded and cylindrical (BL), or deep-threaded and tapered implant macro-design (BLX). The insertion torque was continuously measured during implant placement, and RFA was performed after final implant positioning.</p><p><strong>Results: </strong>One-hundred and forty-four implants were equally distributed to two alveolar ridge morphologies and implant designs. Higher final insertion torque and RFA values were observed for implants placed in healed ridges compared to extraction sockets (40.8 ± 13.5 vs. 20.6 ± 8.4 Ncm, and RFA 70.7 ± 2.8 vs. 59.6 ± 6.5, both p < 0.001), and for BL implants compared to BLX implants (35.7 ± 13.0 vs. 25.7 ± 8.9 Ncm, and RFA 66.7 ± 4.4 vs. 63.6 ± 4.9, both p < 0.001). Insertion torque and mean RFA values positively correlated (r = 0.742; p < 0.001).</p><p><strong>Conclusion: </strong>Primary implant stability is significantly affected by the alveolar ridge morphology and the implant macro-design, demonstrating higher values in healed sites and shallow-threaded, cylindrical implants. Therefore, a tailored selection of the implant design depending on the implant placement and loading protocol is recommended.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"11 1","pages":"17"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-025-00605-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The primary aim of this in vitro study was to investigate the primary implant stability obtained in immediate and late implant placement scenarios. Secondary aims evaluated the effect of two distinct implant macro-designs and examined the correlation between resonance frequency analysis (RFA) and final insertion torque.

Methods: Partially edentulous maxillary models including six single sites simulating extraction sockets and healed alveolar ridges were used. Virtual implant planning facilitated static computer-assisted implant placement of bone level implants with either a shallow-threaded and cylindrical (BL), or deep-threaded and tapered implant macro-design (BLX). The insertion torque was continuously measured during implant placement, and RFA was performed after final implant positioning.

Results: One-hundred and forty-four implants were equally distributed to two alveolar ridge morphologies and implant designs. Higher final insertion torque and RFA values were observed for implants placed in healed ridges compared to extraction sockets (40.8 ± 13.5 vs. 20.6 ± 8.4 Ncm, and RFA 70.7 ± 2.8 vs. 59.6 ± 6.5, both p < 0.001), and for BL implants compared to BLX implants (35.7 ± 13.0 vs. 25.7 ± 8.9 Ncm, and RFA 66.7 ± 4.4 vs. 63.6 ± 4.9, both p < 0.001). Insertion torque and mean RFA values positively correlated (r = 0.742; p < 0.001).

Conclusion: Primary implant stability is significantly affected by the alveolar ridge morphology and the implant macro-design, demonstrating higher values in healed sites and shallow-threaded, cylindrical implants. Therefore, a tailored selection of the implant design depending on the implant placement and loading protocol is recommended.

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信