The REAsmash serious game for the post-stroke diagnosis of distractor inhibition: contrast between immersive and non-immersive virtual reality test versions.

IF 3.3 3区 医学 Q1 REHABILITATION
Gregorio Sorrentino, Khawla Ajana, Gauthier Everard, Florence Vanhoof, Thierry Lejeune, Martin G Edwards
{"title":"The REAsmash serious game for the post-stroke diagnosis of distractor inhibition: contrast between immersive and non-immersive virtual reality test versions.","authors":"Gregorio Sorrentino, Khawla Ajana, Gauthier Everard, Florence Vanhoof, Thierry Lejeune, Martin G Edwards","doi":"10.23736/S1973-9087.25.08680-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Virtual reality (VR) Serious Games (SG) offer greater sensitivity and specificity than traditional diagnostics. The playfulness of the SG reduces stress, enhancing motivation and reliability. We developed immersive (iVR) and non-immersive (niVR) versions of REAsmash, a SG based on Feature Integration Theory (FIT) to assess distractor inhibition attention.</p><p><strong>Aim: </strong>The aim of this study was to verify the transfer of the REAsmash FIT diagnostic properties across VR devices with different degrees of immersion.</p><p><strong>Design: </strong>Cross-sectional clinical study.</p><p><strong>Setting: </strong>Inpatient, outpatient and healthy controls.</p><p><strong>Population: </strong>Post-stroke and healthy individuals.</p><p><strong>Methods: </strong>The REAsmash involves searching for a (target) mole with a red miner's helmet. The target is either presented alone (baseline), or presented with distractors (11, 17 or 23) that contrast the target by high or low saliency (moles with blue miner's and horned helmets vs blue miner's and red horned helmets). Stimuli appeared randomly from a 24-molehill grid. Participants (15 with and history of cortical-subcortical stroke and 15 age matched controls) hit the target with their response hand in niVR and with a virtual hammer in iVR. Post-stroke participants used their less impaired hand, controls their dominant hand. ANOVA tested VR type (niVR vs iVR), group (post-stroke vs healthy), saliency (high vs low) and distractor number (11, 17, 23), with the interaction between saliency and distractor number defining FIT. The dependent variable was relative mean response time, calculated by subtracting the mean baseline response time from each response to targets presented with distractors, for each participant. This variable exemplifies the costs to response time cause by the manipulation of independent variables.</p><p><strong>Results: </strong>We found significant main effects and an interaction for saliency and distractor number, confirming FIT. Group and VR type main effects were significant, with slower responses for post-strokes and for iVR, but with no interactions.</p><p><strong>Conclusions: </strong>To evaluate performance across acute to chronic post-stroke phases, diagnostic measures must be transferable between test devices, ensuring compatibility from hospital to outpatient settings.</p><p><strong>Clinical rehabilitation impact: </strong>Our results demonstrated that the REAsmash diagnostic properties were consistent across immersive and non-immersive VR, as well as within both groups of participants.</p>","PeriodicalId":12044,"journal":{"name":"European journal of physical and rehabilitation medicine","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of physical and rehabilitation medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S1973-9087.25.08680-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Virtual reality (VR) Serious Games (SG) offer greater sensitivity and specificity than traditional diagnostics. The playfulness of the SG reduces stress, enhancing motivation and reliability. We developed immersive (iVR) and non-immersive (niVR) versions of REAsmash, a SG based on Feature Integration Theory (FIT) to assess distractor inhibition attention.

Aim: The aim of this study was to verify the transfer of the REAsmash FIT diagnostic properties across VR devices with different degrees of immersion.

Design: Cross-sectional clinical study.

Setting: Inpatient, outpatient and healthy controls.

Population: Post-stroke and healthy individuals.

Methods: The REAsmash involves searching for a (target) mole with a red miner's helmet. The target is either presented alone (baseline), or presented with distractors (11, 17 or 23) that contrast the target by high or low saliency (moles with blue miner's and horned helmets vs blue miner's and red horned helmets). Stimuli appeared randomly from a 24-molehill grid. Participants (15 with and history of cortical-subcortical stroke and 15 age matched controls) hit the target with their response hand in niVR and with a virtual hammer in iVR. Post-stroke participants used their less impaired hand, controls their dominant hand. ANOVA tested VR type (niVR vs iVR), group (post-stroke vs healthy), saliency (high vs low) and distractor number (11, 17, 23), with the interaction between saliency and distractor number defining FIT. The dependent variable was relative mean response time, calculated by subtracting the mean baseline response time from each response to targets presented with distractors, for each participant. This variable exemplifies the costs to response time cause by the manipulation of independent variables.

Results: We found significant main effects and an interaction for saliency and distractor number, confirming FIT. Group and VR type main effects were significant, with slower responses for post-strokes and for iVR, but with no interactions.

Conclusions: To evaluate performance across acute to chronic post-stroke phases, diagnostic measures must be transferable between test devices, ensuring compatibility from hospital to outpatient settings.

Clinical rehabilitation impact: Our results demonstrated that the REAsmash diagnostic properties were consistent across immersive and non-immersive VR, as well as within both groups of participants.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.50
自引率
4.40%
发文量
162
审稿时长
6-12 weeks
期刊介绍: The European Journal of Physical and Rehabilitation Medicine publishes papers of clinical interest in physical and rehabilitation medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信