Enhancing corrosion resistance and bioactive behavior of porous metallic scaffolds through electrochemical coatings

IF 7.5 Q1 CHEMISTRY, PHYSICAL
Julio E. de la Rosa , Cristina García-Cabezón , Celia García-Hernández , Ernesto J. Delgado-Pujol , Francisco J. García-García , Aldo R. Bocaccini , Fernando Martín-Pedrosa , Yadir Torres
{"title":"Enhancing corrosion resistance and bioactive behavior of porous metallic scaffolds through electrochemical coatings","authors":"Julio E. de la Rosa ,&nbsp;Cristina García-Cabezón ,&nbsp;Celia García-Hernández ,&nbsp;Ernesto J. Delgado-Pujol ,&nbsp;Francisco J. García-García ,&nbsp;Aldo R. Bocaccini ,&nbsp;Fernando Martín-Pedrosa ,&nbsp;Yadir Torres","doi":"10.1016/j.apsadv.2025.100723","DOIUrl":null,"url":null,"abstract":"<div><div>The percentage and size of the pores obtained by conventional powder metallurgy route, as well as corrosion phenomena and poor bioactivity, limit the clinical success of porous metallic implants. In this work, a joint solution is proposed, combining the manufacture of bone implants by the loose sintering technique (economical, repetitive and maximized porosity), coated with chitosan-bioactive glass bio-composites synthesized by chronoamperometry and electrophoresis techniques. The influence of porosity on the biomechanical and biofunctional behavior of titanium substrates is evaluated, as well as the role of bioactive coatings in improving their corrosion resistance and osteoinduction capacity. These electrochemical methods are optimized and presented as a promising strategy for developing uniform protective coatings. Biodegradable coatings based on chitosan are replaced by calcium phosphates that form on the surface of the implants, promoted by the effect of bioactive glass reinforcements (BG-45S5 and BG-1393). Chitosan-bioactive glass composite coatings significantly improved the corrosion resistance of titanium substrates. Loose sintering samples exhibited a 94 % reduction in corrosion current density reaching 1.08·10–6 A/cm2 and a polarization resistance of 14·103 Ω/cm2 with BG-1393. The in vitro bioactivity study confirmed apatite formation after immersion in SBF, with a Ca/P ratio close to natural hydroxyapatite (1.67), particularly for chitosan with BG-45S5 (achieving 1.76).</div></div>","PeriodicalId":34303,"journal":{"name":"Applied Surface Science Advances","volume":"26 ","pages":"Article 100723"},"PeriodicalIF":7.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Surface Science Advances","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666523925000315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The percentage and size of the pores obtained by conventional powder metallurgy route, as well as corrosion phenomena and poor bioactivity, limit the clinical success of porous metallic implants. In this work, a joint solution is proposed, combining the manufacture of bone implants by the loose sintering technique (economical, repetitive and maximized porosity), coated with chitosan-bioactive glass bio-composites synthesized by chronoamperometry and electrophoresis techniques. The influence of porosity on the biomechanical and biofunctional behavior of titanium substrates is evaluated, as well as the role of bioactive coatings in improving their corrosion resistance and osteoinduction capacity. These electrochemical methods are optimized and presented as a promising strategy for developing uniform protective coatings. Biodegradable coatings based on chitosan are replaced by calcium phosphates that form on the surface of the implants, promoted by the effect of bioactive glass reinforcements (BG-45S5 and BG-1393). Chitosan-bioactive glass composite coatings significantly improved the corrosion resistance of titanium substrates. Loose sintering samples exhibited a 94 % reduction in corrosion current density reaching 1.08·10–6 A/cm2 and a polarization resistance of 14·103 Ω/cm2 with BG-1393. The in vitro bioactivity study confirmed apatite formation after immersion in SBF, with a Ca/P ratio close to natural hydroxyapatite (1.67), particularly for chitosan with BG-45S5 (achieving 1.76).
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.10
自引率
1.60%
发文量
128
审稿时长
66 days
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信