Error-based dynamic velocity range of PIV processing algorithms

IF 2.3 3区 工程技术 Q2 ENGINEERING, MECHANICAL
Gauresh Raj Jassal, Bryan E. Schmidt
{"title":"Error-based dynamic velocity range of PIV processing algorithms","authors":"Gauresh Raj Jassal,&nbsp;Bryan E. Schmidt","doi":"10.1007/s00348-025-03998-y","DOIUrl":null,"url":null,"abstract":"<div><p>The ability of PIV processing algorithms to accurately determine velocity vectors across the range of motion present in PIV images is characterized by the algorithm’s dynamic velocity range (DVR). Conventionally, the DVR of PIV is defined using the ratio between the maximum and minimum resolvable particle displacements, with the minimum based on the uncertainty in the location of a single particle in the optical system. In this work, it is demonstrated that this definition is inadequate in practice, as it ignores many factors which affect the accuracy of an algorithm when determining small displacements, and the error in vectors with small magnitudes in actual flows is often many times larger than the theoretical minimum. A more useful criterion for determining the DVR of a PIV setup is proposed that depends on conditional errors, using synthetic data to produce a known ground truth. The introduced error-based DVR accounts for the effect of multiple flow velocity scales present in a PIV experiment as well as multi-particle effects. It is found that the practical, error-based DVR of cross-correlation-based PIV is highly experiment-dependent and much lower than the widely accepted value of <span>\\(\\mathcal {O} \\left( {10^2} \\right)\\)</span>, typically <span>\\(\\mathcal {O} \\left( {10^0} \\right) - \\left( {10^1} \\right)\\)</span>. The findings from the synthetic data results are corroborated using experimental PIV data to approximate the DVR via a deviation-based approach when the ground truth is unknown.</p></div>","PeriodicalId":554,"journal":{"name":"Experiments in Fluids","volume":"66 4","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s00348-025-03998-y.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experiments in Fluids","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s00348-025-03998-y","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The ability of PIV processing algorithms to accurately determine velocity vectors across the range of motion present in PIV images is characterized by the algorithm’s dynamic velocity range (DVR). Conventionally, the DVR of PIV is defined using the ratio between the maximum and minimum resolvable particle displacements, with the minimum based on the uncertainty in the location of a single particle in the optical system. In this work, it is demonstrated that this definition is inadequate in practice, as it ignores many factors which affect the accuracy of an algorithm when determining small displacements, and the error in vectors with small magnitudes in actual flows is often many times larger than the theoretical minimum. A more useful criterion for determining the DVR of a PIV setup is proposed that depends on conditional errors, using synthetic data to produce a known ground truth. The introduced error-based DVR accounts for the effect of multiple flow velocity scales present in a PIV experiment as well as multi-particle effects. It is found that the practical, error-based DVR of cross-correlation-based PIV is highly experiment-dependent and much lower than the widely accepted value of \(\mathcal {O} \left( {10^2} \right)\), typically \(\mathcal {O} \left( {10^0} \right) - \left( {10^1} \right)\). The findings from the synthetic data results are corroborated using experimental PIV data to approximate the DVR via a deviation-based approach when the ground truth is unknown.

基于误差的PIV动态速度范围处理算法
PIV处理算法能够准确地确定PIV图像中存在的运动范围内的速度矢量,其特点是该算法的动态速度范围(DVR)。传统上,PIV的DVR是用最大和最小可分辨粒子位移的比值来定义的,最小值是基于光学系统中单个粒子位置的不确定性。在这项工作中,证明了该定义在实践中是不充分的,因为它忽略了在确定小位移时影响算法精度的许多因素,并且在实际流动中具有小幅度的矢量的误差通常比理论最小值大许多倍。提出了一种更有用的标准来确定PIV设置的DVR,该标准依赖于条件误差,使用合成数据来产生已知的基础真值。引入的基于误差的DVR考虑了PIV实验中存在的多个流速尺度以及多粒子效应的影响。研究发现,基于互相关的PIV的实用的基于误差的DVR高度依赖于实验,并且远低于广泛接受的值\(\mathcal {O} \left( {10^2} \right)\),通常为\(\mathcal {O} \left( {10^0} \right) - \left( {10^1} \right)\)。在地面真实值未知的情况下,使用实验PIV数据通过基于偏差的方法来近似DVR,证实了合成数据结果的发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Experiments in Fluids
Experiments in Fluids 工程技术-工程:机械
CiteScore
5.10
自引率
12.50%
发文量
157
审稿时长
3.8 months
期刊介绍: Experiments in Fluids examines the advancement, extension, and improvement of new techniques of flow measurement. The journal also publishes contributions that employ existing experimental techniques to gain an understanding of the underlying flow physics in the areas of turbulence, aerodynamics, hydrodynamics, convective heat transfer, combustion, turbomachinery, multi-phase flows, and chemical, biological and geological flows. In addition, readers will find papers that report on investigations combining experimental and analytical/numerical approaches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信