{"title":"A performance compensation method for miniaturized LIBS instruments in precise rock classification","authors":"Yuting Fu, Jing Chen, Biye Liu, Beibei Hu, Xueying Jin, Guang Yang and Huihui Sun","doi":"10.1039/D4JA00453A","DOIUrl":null,"url":null,"abstract":"<p >Rocks, as one of the most ubiquitous substances on Earth, bear the historical records of Earth's evolution and traces of geological processes. Rock identification can reveal the geological environment and resource distribution, which are important for geological research. Laser-induced breakdown spectroscopy (LIBS), a real-time, micro-destructive, and multi-element simultaneous analysis technique, has played an important role in rock identification and geological research. However, traditional laboratory-based LIBS instruments are bulky and unsuitable for field site geological exploration. While handheld LIBS instruments offer compactness and convenience, they suffer from reduced laser energy and spectrometer performance, potentially compromising analytical accuracy. There is an urgent demand for a miniaturized LIBS instrument that retains the high analytical capabilities of laboratory-based LIBS while incorporating the portability of handheld LIBS. This study proposes a compensation method for the performance loss of miniaturized LIBS instruments due to their reduced size. We designed six experimental setups of different sizes to compare rock spectra and classification accuracy in detail, aiming to validate the performance loss of a miniaturized LIBS instrument. In our experiments, the miniaturized LIBS instrument, equipped with an MPL-H-1064 laser and an AvaSpec Mini2048 spectrometer, was employed to classify 16 types of rocks using the SVM model, achieving an initial classification accuracy of 77.08%. To compensate for the performance loss inherent in miniaturized LIBS instruments, a range of preprocessing methods and principal component analysis (PCA) were employed to enhance spectral quality and elevate the accuracy of rock classification to 96.25%. Additionally, the Optuna framework was used to automatically search for the optimal hyperparameters of the SVM model, subsequently increasing the accuracy of rock classification to 99.58%. The results demonstrate that this method effectively mitigates the performance loss of miniaturized LIBS instruments and achieves precise rock classification.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 3","pages":" 715-726"},"PeriodicalIF":3.1000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d4ja00453a","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Rocks, as one of the most ubiquitous substances on Earth, bear the historical records of Earth's evolution and traces of geological processes. Rock identification can reveal the geological environment and resource distribution, which are important for geological research. Laser-induced breakdown spectroscopy (LIBS), a real-time, micro-destructive, and multi-element simultaneous analysis technique, has played an important role in rock identification and geological research. However, traditional laboratory-based LIBS instruments are bulky and unsuitable for field site geological exploration. While handheld LIBS instruments offer compactness and convenience, they suffer from reduced laser energy and spectrometer performance, potentially compromising analytical accuracy. There is an urgent demand for a miniaturized LIBS instrument that retains the high analytical capabilities of laboratory-based LIBS while incorporating the portability of handheld LIBS. This study proposes a compensation method for the performance loss of miniaturized LIBS instruments due to their reduced size. We designed six experimental setups of different sizes to compare rock spectra and classification accuracy in detail, aiming to validate the performance loss of a miniaturized LIBS instrument. In our experiments, the miniaturized LIBS instrument, equipped with an MPL-H-1064 laser and an AvaSpec Mini2048 spectrometer, was employed to classify 16 types of rocks using the SVM model, achieving an initial classification accuracy of 77.08%. To compensate for the performance loss inherent in miniaturized LIBS instruments, a range of preprocessing methods and principal component analysis (PCA) were employed to enhance spectral quality and elevate the accuracy of rock classification to 96.25%. Additionally, the Optuna framework was used to automatically search for the optimal hyperparameters of the SVM model, subsequently increasing the accuracy of rock classification to 99.58%. The results demonstrate that this method effectively mitigates the performance loss of miniaturized LIBS instruments and achieves precise rock classification.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信