Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ezzat Elmoujarkach;Steven Seeger;Luise Morgner;Fabian Schmidt;Julia G. Mannheim;Christian L. Schmidt;Magdalena Rafecas
{"title":"Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET","authors":"Ezzat Elmoujarkach;Steven Seeger;Luise Morgner;Fabian Schmidt;Julia G. Mannheim;Christian L. Schmidt;Magdalena Rafecas","doi":"10.1109/TRPMS.2024.3483233","DOIUrl":null,"url":null,"abstract":"This study explores the potential of digital light processing to 3-D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3-D printer and mixtures of 18F-FDG (T1/2: 109.8 min) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultrahigh-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multiline phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (National Electrical Manufacturers Association NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% versus 72%) and peak-to-valley ratio (75.3 versus 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"9 3","pages":"362-371"},"PeriodicalIF":4.6000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10742298","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10742298/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study explores the potential of digital light processing to 3-D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3-D printer and mixtures of 18F-FDG (T1/2: 109.8 min) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultrahigh-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multiline phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (National Electrical Manufacturers Association NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% versus 72%) and peak-to-valley ratio (75.3 versus 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信