Uptake of Per- and Polyfluoroalkyl Substances into Concrete from Aqueous Film-Forming Foams: Experimental Investigations and Comparison to Field-Impacted Samples
David Lutes, Andrew Boyd, Lachlan J. Jekimovs, Brett R. Hamilton, Jochen F. Mueller, Richard Arnseth, Ian Ross, Jinxia Liu
{"title":"Uptake of Per- and Polyfluoroalkyl Substances into Concrete from Aqueous Film-Forming Foams: Experimental Investigations and Comparison to Field-Impacted Samples","authors":"David Lutes, Andrew Boyd, Lachlan J. Jekimovs, Brett R. Hamilton, Jochen F. Mueller, Richard Arnseth, Ian Ross, Jinxia Liu","doi":"10.1021/acs.est.4c12878","DOIUrl":null,"url":null,"abstract":"The widespread use of aqueous film-forming foams (AFFFs) in firefighting has led to significant contamination by per- and polyfluoroalkyl substances (PFAS), including in building materials like concrete. This study investigated the initial phase of PFAS contamination in concrete, focusing on factors influencing PFAS retention and penetration. Laboratory experiments assessed the uptake kinetics of PFAS into concrete over one year, revealing that PFAS penetrated beyond surface layers, as confirmed by high-resolution mass spectrometry and desorption electrospray ionization mass spectrometry imaging. PFAS mass loss into the concrete was limited, with 0.99% to 18.5% (mean 6.6%) of initial spiked PFAS being retained. Uptake behaviors were influenced by PFAS chain length and chemistry, concrete surface characteristics, as well as wetting/drying cycles, which accelerated PFAS penetration through the wick effect. Damaged concrete surfaces also showed faster PFAS penetration due to the exposed interfacial transition zones. Field-impacted concrete samples from Canada revealed some similar migration trends with lab-exposed concrete, with shorter-chain PFAS exhibiting greater mobility in the concrete matrix, though notable differences were observed between field and lab samples. These findings highlight the complex dynamics of PFAS contamination in concrete and provide insights into factors affecting PFAS penetration and retention.","PeriodicalId":36,"journal":{"name":"环境科学与技术","volume":"52 1","pages":""},"PeriodicalIF":10.8000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"环境科学与技术","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1021/acs.est.4c12878","RegionNum":1,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
The widespread use of aqueous film-forming foams (AFFFs) in firefighting has led to significant contamination by per- and polyfluoroalkyl substances (PFAS), including in building materials like concrete. This study investigated the initial phase of PFAS contamination in concrete, focusing on factors influencing PFAS retention and penetration. Laboratory experiments assessed the uptake kinetics of PFAS into concrete over one year, revealing that PFAS penetrated beyond surface layers, as confirmed by high-resolution mass spectrometry and desorption electrospray ionization mass spectrometry imaging. PFAS mass loss into the concrete was limited, with 0.99% to 18.5% (mean 6.6%) of initial spiked PFAS being retained. Uptake behaviors were influenced by PFAS chain length and chemistry, concrete surface characteristics, as well as wetting/drying cycles, which accelerated PFAS penetration through the wick effect. Damaged concrete surfaces also showed faster PFAS penetration due to the exposed interfacial transition zones. Field-impacted concrete samples from Canada revealed some similar migration trends with lab-exposed concrete, with shorter-chain PFAS exhibiting greater mobility in the concrete matrix, though notable differences were observed between field and lab samples. These findings highlight the complex dynamics of PFAS contamination in concrete and provide insights into factors affecting PFAS penetration and retention.
期刊介绍:
Environmental Science & Technology (ES&T) is a co-sponsored academic and technical magazine by the Hubei Provincial Environmental Protection Bureau and the Hubei Provincial Academy of Environmental Sciences.
Environmental Science & Technology (ES&T) holds the status of Chinese core journals, scientific papers source journals of China, Chinese Science Citation Database source journals, and Chinese Academic Journal Comprehensive Evaluation Database source journals. This publication focuses on the academic field of environmental protection, featuring articles related to environmental protection and technical advancements.