An Overview of Anesthetic Procedures for Ferret (Mustela putorius furo) Preclinical Brain MRI: A Call for Standardization.

Diego Celdran-Bonafonte, Kathryn A O'Connell, Laurel Dieckhaus, Emily Mocarski, Natalie M Adras, Elisabeth B Hutchinson, Cholawat Pacharinsak
{"title":"An Overview of Anesthetic Procedures for Ferret (Mustela putorius furo) Preclinical Brain MRI: A Call for Standardization.","authors":"Diego Celdran-Bonafonte, Kathryn A O'Connell, Laurel Dieckhaus, Emily Mocarski, Natalie M Adras, Elisabeth B Hutchinson, Cholawat Pacharinsak","doi":"10.30802/AALAS-JAALAS-24-086","DOIUrl":null,"url":null,"abstract":"<p><p>Neuroscience research has been increasingly active during the last 2 decades, largely driven by the high prevalence and increasing burden of neurologic disorders. While rodents are essential models for biomedical research of neurologic disorders, they lack similar brain anatomy and protein expression profiles to humans, thus limiting their translational value as models of traumatic brain injury, stroke, Alzheimer's disease, and Parkinson's disease. The use of ferrets as a model species in neuroscience has been increasing due to their neuroanatomical similarities with humans, including a gyrencephalic brain and larger white matter-to-gray matter ratio. Compared with nonhuman primates, sheep, and swine, ferrets also have the advantages of reduced size, lower housing costs, and lower phylogenetic order. These, among other advantages, make ferrets a promising species to bridge research gaps and complement traditional rodent studies. Although modern neuroscience research in ferrets relies heavily on advanced imaging techniques such as magnetic resonance imaging (MRI), most of the preclinical MRI installations are not designed or optimized for use with ferrets. In this paper we discuss the intricacies and limitations that need to be considered when performing ferret MRI procedures. Reviews of ferret biologic peculiarities, anesthetic protocols, management of complications, and the impact of these factors on MRI outcomes are presented. Standardizing anesthesia protocols for the conduct of MRI in ferrets will aid in better physiologic monitoring as well as imaging outcomes that ultimately benefit the science being conducted.</p>","PeriodicalId":94111,"journal":{"name":"Journal of the American Association for Laboratory Animal Science : JAALAS","volume":"64 1","pages":"16-28"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11808380/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Association for Laboratory Animal Science : JAALAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30802/AALAS-JAALAS-24-086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Neuroscience research has been increasingly active during the last 2 decades, largely driven by the high prevalence and increasing burden of neurologic disorders. While rodents are essential models for biomedical research of neurologic disorders, they lack similar brain anatomy and protein expression profiles to humans, thus limiting their translational value as models of traumatic brain injury, stroke, Alzheimer's disease, and Parkinson's disease. The use of ferrets as a model species in neuroscience has been increasing due to their neuroanatomical similarities with humans, including a gyrencephalic brain and larger white matter-to-gray matter ratio. Compared with nonhuman primates, sheep, and swine, ferrets also have the advantages of reduced size, lower housing costs, and lower phylogenetic order. These, among other advantages, make ferrets a promising species to bridge research gaps and complement traditional rodent studies. Although modern neuroscience research in ferrets relies heavily on advanced imaging techniques such as magnetic resonance imaging (MRI), most of the preclinical MRI installations are not designed or optimized for use with ferrets. In this paper we discuss the intricacies and limitations that need to be considered when performing ferret MRI procedures. Reviews of ferret biologic peculiarities, anesthetic protocols, management of complications, and the impact of these factors on MRI outcomes are presented. Standardizing anesthesia protocols for the conduct of MRI in ferrets will aid in better physiologic monitoring as well as imaging outcomes that ultimately benefit the science being conducted.

雪貂(Mustela putorius furo)临床前脑磁共振成像麻醉程序概述:呼吁标准化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信