Ivan Triangto, Aulia Syavitri Dhamayanti, Made Suariastawa Putra, Djoko Witjaksono, Rahmad, Lilik Zuhriyah, Yoga Waranugraha
{"title":"Correlation of Sit-to-Stand Test and 6-Minute Walk Test to Illustrate Cardiorespiratory Fitness in Systolic Heart Failure Patients.","authors":"Ivan Triangto, Aulia Syavitri Dhamayanti, Made Suariastawa Putra, Djoko Witjaksono, Rahmad, Lilik Zuhriyah, Yoga Waranugraha","doi":"10.5535/arm.240057","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To prove 5-time sit-to-stand (5-STS) and 30-second sit-to-stand (30sSTS) tests in assessing cardiorespiratory fitness in chronic heart failure (HF) patients with systolic dysfunction. Alternative tests, such as 5-STS and 30sSTS, may be used to assess cardiorespiratory fitness in patients with HF but have not been thoroughly evaluated. Thus, this study aimed to prove 5-STS and 30sSTS tests in assessing cardiorespiratory fitness in chronic HF patients with systolic dysfunction.</p><p><strong>Methods: </strong>A cross-sectional study was done, evaluating chronic HF patients with systolic dysfunction that have received optimal guideline directed medical treatment for at least 3 months. All patients underwent the same intervention on the same day, starting with an initial 5-STS test, followed by a 30sSTS, and a 6-minute walk test (6MWT).</p><p><strong>Results: </strong>A total of 34 patients were enrolled in this study. The median left ventricular ejection fraction was 44% (interquartile range=34%-48%). Mean values of 5-STS, 30sSTS, and 6MWT were 13.90±4.72, 13.29±3.38, and 463.65±87.04, respectively. 5-STS showed moderate correlation with 6MWT (r=-0.436, p=0.01). However, the 30sSTS revealed strong correlation with 6MWT (r=0.629, p<0.001).</p><p><strong>Conclusion: </strong>The 30sSTS test had strong correlation with 6MWT. It could be used to illustrate cardiorespiratory fitness in chronic HF patients with systolic dysfunction.</p>","PeriodicalId":47738,"journal":{"name":"Annals of Rehabilitation Medicine-ARM","volume":"49 1","pages":"23-29"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11895058/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Rehabilitation Medicine-ARM","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5535/arm.240057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To prove 5-time sit-to-stand (5-STS) and 30-second sit-to-stand (30sSTS) tests in assessing cardiorespiratory fitness in chronic heart failure (HF) patients with systolic dysfunction. Alternative tests, such as 5-STS and 30sSTS, may be used to assess cardiorespiratory fitness in patients with HF but have not been thoroughly evaluated. Thus, this study aimed to prove 5-STS and 30sSTS tests in assessing cardiorespiratory fitness in chronic HF patients with systolic dysfunction.
Methods: A cross-sectional study was done, evaluating chronic HF patients with systolic dysfunction that have received optimal guideline directed medical treatment for at least 3 months. All patients underwent the same intervention on the same day, starting with an initial 5-STS test, followed by a 30sSTS, and a 6-minute walk test (6MWT).
Results: A total of 34 patients were enrolled in this study. The median left ventricular ejection fraction was 44% (interquartile range=34%-48%). Mean values of 5-STS, 30sSTS, and 6MWT were 13.90±4.72, 13.29±3.38, and 463.65±87.04, respectively. 5-STS showed moderate correlation with 6MWT (r=-0.436, p=0.01). However, the 30sSTS revealed strong correlation with 6MWT (r=0.629, p<0.001).
Conclusion: The 30sSTS test had strong correlation with 6MWT. It could be used to illustrate cardiorespiratory fitness in chronic HF patients with systolic dysfunction.