Basis function model to extract the combined confocal and fall-off function from multiple optical coherence tomography A-scans.

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2025-02-01 Epub Date: 2025-02-26 DOI:10.1117/1.JBO.30.2.025003
Daniel J Phan, Martin Were, Jörn-Hendrik Weitkamp, Audrey K Bowden
{"title":"Basis function model to extract the combined confocal and fall-off function from multiple optical coherence tomography A-scans.","authors":"Daniel J Phan, Martin Were, Jörn-Hendrik Weitkamp, Audrey K Bowden","doi":"10.1117/1.JBO.30.2.025003","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Many derivatives of optical coherence tomography (OCT) rely on the depth-dependent information of the sample in the image. System depth-dependent effects, such as the confocal effect and the sensitivity fall-off, should be corrected to improve the accuracy of the images and information derived from them.</p><p><strong>Aim: </strong>We developed a new single-shot method to extract the combined confocal and fall-off functions and remove system-generated depth-dependent effects from OCT images.</p><p><strong>Approach: </strong>The combined function is modeled as a linear combination of basis functions whose coefficients are found from two or more A-scans (or B-scans) of a sample that are vertically shifted within the imaging range. No prior knowledge of the OCT system parameters or assumed form for the confocal and fall-off functions is needed.</p><p><strong>Results: </strong>The method was derived and validated with simulations and OCT images of a phantom, a biological sample, and human retina. Improvement over the Ratio Fit method was demonstrated.</p><p><strong>Conclusions: </strong>The improvement in the extraction of the combined confocal and fall-off effects by this method should lead to improved medical diagnosis through more accurate attenuation coefficient calculations. The method enables future applications of OCT where precise removal of all depth-dependent effects on OCT images is critical.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"30 2","pages":"025003"},"PeriodicalIF":3.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11868661/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.30.2.025003","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Many derivatives of optical coherence tomography (OCT) rely on the depth-dependent information of the sample in the image. System depth-dependent effects, such as the confocal effect and the sensitivity fall-off, should be corrected to improve the accuracy of the images and information derived from them.

Aim: We developed a new single-shot method to extract the combined confocal and fall-off functions and remove system-generated depth-dependent effects from OCT images.

Approach: The combined function is modeled as a linear combination of basis functions whose coefficients are found from two or more A-scans (or B-scans) of a sample that are vertically shifted within the imaging range. No prior knowledge of the OCT system parameters or assumed form for the confocal and fall-off functions is needed.

Results: The method was derived and validated with simulations and OCT images of a phantom, a biological sample, and human retina. Improvement over the Ratio Fit method was demonstrated.

Conclusions: The improvement in the extraction of the combined confocal and fall-off effects by this method should lead to improved medical diagnosis through more accurate attenuation coefficient calculations. The method enables future applications of OCT where precise removal of all depth-dependent effects on OCT images is critical.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信