Prediction of short-term anatomic prognosis for central serous chorioretinopathy using a generative adversarial network.

IF 2.4 3区 医学 Q2 OPHTHALMOLOGY
Ho Ra, Donghyun Jee, Suyeon Han, Seung-Hoon Lee, Jin-Woo Kwon, Yunhea Jung, Jiwon Baek
{"title":"Prediction of short-term anatomic prognosis for central serous chorioretinopathy using a generative adversarial network.","authors":"Ho Ra, Donghyun Jee, Suyeon Han, Seung-Hoon Lee, Jin-Woo Kwon, Yunhea Jung, Jiwon Baek","doi":"10.1007/s00417-025-06786-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To train generative adversarial network (GAN) models to generate predictive optical coherence tomography (OCT) images of central serous chorioretinopathy (CSC) at 3 months after observation using multi-modal OCT images.</p><p><strong>Methods: </strong>Four hundred forty CSC eyes of 440 patients who underwent Cirrus OCT imaging were included. Baseline OCT B-scan images through the foveal center, en face choroid, and en face ellipsoid zone were collected from each patient. The datasets were divided into training and validation (n = 390) and test (n = 50) sets. The input images for each model comprised either baseline B-scan alone or a combination of en face choroid and ellipsoid zones. Predictive post-treatment OCT B-scan images were generated using GAN models and compared with real 3-month images.</p><p><strong>Results: </strong>Of 50 generated OCT images, there were 48, 47, and 48 acceptable images for UNIT, CycleGAN, and RegGAN, respectively. In comparison with real 3-month images, the generated images showed sensitivity, specificity, and positive predictive values (PPV) for residual fluid in the ranges of 0.762-1.000, 0.483-0.724, and 0.583-0.704; for pigment epithelial detachment (PED) of 0.917-1.000, 0.974-1.000, and 0.917-1.000; and for subretinal hyperreflective material (SHRM) of 0.667-0.778, 0.925-0.950 and 0.700-0.750, respectively. RegGAN exhibited the highest values except for sensitivity.</p><p><strong>Conclusions: </strong>GAN models could generate prognostic OCT images with good performance for prediction of residual fluid, PED, and SHRM presence in CSC. Implementation of the models may help predict disease activity in CSC, facilitating the establishment of a proper treatment plan.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-025-06786-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To train generative adversarial network (GAN) models to generate predictive optical coherence tomography (OCT) images of central serous chorioretinopathy (CSC) at 3 months after observation using multi-modal OCT images.

Methods: Four hundred forty CSC eyes of 440 patients who underwent Cirrus OCT imaging were included. Baseline OCT B-scan images through the foveal center, en face choroid, and en face ellipsoid zone were collected from each patient. The datasets were divided into training and validation (n = 390) and test (n = 50) sets. The input images for each model comprised either baseline B-scan alone or a combination of en face choroid and ellipsoid zones. Predictive post-treatment OCT B-scan images were generated using GAN models and compared with real 3-month images.

Results: Of 50 generated OCT images, there were 48, 47, and 48 acceptable images for UNIT, CycleGAN, and RegGAN, respectively. In comparison with real 3-month images, the generated images showed sensitivity, specificity, and positive predictive values (PPV) for residual fluid in the ranges of 0.762-1.000, 0.483-0.724, and 0.583-0.704; for pigment epithelial detachment (PED) of 0.917-1.000, 0.974-1.000, and 0.917-1.000; and for subretinal hyperreflective material (SHRM) of 0.667-0.778, 0.925-0.950 and 0.700-0.750, respectively. RegGAN exhibited the highest values except for sensitivity.

Conclusions: GAN models could generate prognostic OCT images with good performance for prediction of residual fluid, PED, and SHRM presence in CSC. Implementation of the models may help predict disease activity in CSC, facilitating the establishment of a proper treatment plan.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
398
审稿时长
3 months
期刊介绍: Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信