Safety and efficacy of frequency-doubled Nd-YAG laser photocoagulation of different types of corneal neovascularisation (NLPC): a prospective study.

IF 2 Q2 OPHTHALMOLOGY
Keerti Wali, Shilpa Maled, Ronak Solanki, Apoorva G Ayachit, Aniket N Shastri
{"title":"Safety and efficacy of frequency-doubled Nd-YAG laser photocoagulation of different types of corneal neovascularisation (NLPC): a prospective study.","authors":"Keerti Wali, Shilpa Maled, Ronak Solanki, Apoorva G Ayachit, Aniket N Shastri","doi":"10.1136/bmjophth-2024-001734","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Frequency doubling of neodymium-doped yttrium aluminum garnet (Nd-YAG) laser results in emission of photocoagulating 532 nm light compared with photolytic 1064 nm emission. The ergonomic benefits of solid-state lasers led to replacement of older coagulating lasers in ophthalmic centres by frequency-doubled Nd-YAG laser. Our study aims to evaluate safety and efficacy of frequency-doubled Nd-YAG laser for photocoagulation of corneal neovascularisation (NLPC).</p><p><strong>Methods: </strong>30 quiet eyes of 28 patients with superficial, mid-stromal and deep stromal inactive corneal neovascularisation were subjected to laser photocoagulation. Resolution of vessels, procedural complications and survival of subsequent corneal grafts were monitored for 3 months. Anterior segment fluorescein angiography (AS-FA) was performed in six eyes to confirm the cessation of blood flow.</p><p><strong>Results: </strong>20 eyes (66.66%) had complete resolution of neovascularisation. 13 cases of superficial (92.86%) and 6 cases of mid-stromal neovascularisation (75%) showed significant resolution, compared with 1 case of deep neovascularisation (12.5%). Minimal corneal burn (n=4, 13.33%), iris holes (n=3, 10%), anterior chamber bubbles (n=5, 16.67%), self-resolving intrastromal bleed (n=2, 6.67%) and graft-host junctional wound leak (n=1 of 12 keratoplasty cases, 8.33%) were noted.</p><p><strong>Conclusion: </strong>NLPC may especially be useful in the eyes with a large vessel arborising within stroma. Lack of comparison with other treatment options leading to inflated safety and efficacy profile of NLPC is the major limitation of this study.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"10 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11877233/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2024-001734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Frequency doubling of neodymium-doped yttrium aluminum garnet (Nd-YAG) laser results in emission of photocoagulating 532 nm light compared with photolytic 1064 nm emission. The ergonomic benefits of solid-state lasers led to replacement of older coagulating lasers in ophthalmic centres by frequency-doubled Nd-YAG laser. Our study aims to evaluate safety and efficacy of frequency-doubled Nd-YAG laser for photocoagulation of corneal neovascularisation (NLPC).

Methods: 30 quiet eyes of 28 patients with superficial, mid-stromal and deep stromal inactive corneal neovascularisation were subjected to laser photocoagulation. Resolution of vessels, procedural complications and survival of subsequent corneal grafts were monitored for 3 months. Anterior segment fluorescein angiography (AS-FA) was performed in six eyes to confirm the cessation of blood flow.

Results: 20 eyes (66.66%) had complete resolution of neovascularisation. 13 cases of superficial (92.86%) and 6 cases of mid-stromal neovascularisation (75%) showed significant resolution, compared with 1 case of deep neovascularisation (12.5%). Minimal corneal burn (n=4, 13.33%), iris holes (n=3, 10%), anterior chamber bubbles (n=5, 16.67%), self-resolving intrastromal bleed (n=2, 6.67%) and graft-host junctional wound leak (n=1 of 12 keratoplasty cases, 8.33%) were noted.

Conclusion: NLPC may especially be useful in the eyes with a large vessel arborising within stroma. Lack of comparison with other treatment options leading to inflated safety and efficacy profile of NLPC is the major limitation of this study.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Open Ophthalmology
BMJ Open Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
4.20%
发文量
104
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信