Safety and efficacy of frequency-doubled Nd-YAG laser photocoagulation of different types of corneal neovascularisation (NLPC): a prospective study.

IF 2 Q2 OPHTHALMOLOGY
Keerti Wali, Shilpa Maled, Ronak Solanki, Apoorva G Ayachit, Aniket N Shastri
{"title":"Safety and efficacy of frequency-doubled Nd-YAG laser photocoagulation of different types of corneal neovascularisation (NLPC): a prospective study.","authors":"Keerti Wali, Shilpa Maled, Ronak Solanki, Apoorva G Ayachit, Aniket N Shastri","doi":"10.1136/bmjophth-2024-001734","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Frequency doubling of neodymium-doped yttrium aluminum garnet (Nd-YAG) laser results in emission of photocoagulating 532 nm light compared with photolytic 1064 nm emission. The ergonomic benefits of solid-state lasers led to replacement of older coagulating lasers in ophthalmic centres by frequency-doubled Nd-YAG laser. Our study aims to evaluate safety and efficacy of frequency-doubled Nd-YAG laser for photocoagulation of corneal neovascularisation (NLPC).</p><p><strong>Methods: </strong>30 quiet eyes of 28 patients with superficial, mid-stromal and deep stromal inactive corneal neovascularisation were subjected to laser photocoagulation. Resolution of vessels, procedural complications and survival of subsequent corneal grafts were monitored for 3 months. Anterior segment fluorescein angiography (AS-FA) was performed in six eyes to confirm the cessation of blood flow.</p><p><strong>Results: </strong>20 eyes (66.66%) had complete resolution of neovascularisation. 13 cases of superficial (92.86%) and 6 cases of mid-stromal neovascularisation (75%) showed significant resolution, compared with 1 case of deep neovascularisation (12.5%). Minimal corneal burn (n=4, 13.33%), iris holes (n=3, 10%), anterior chamber bubbles (n=5, 16.67%), self-resolving intrastromal bleed (n=2, 6.67%) and graft-host junctional wound leak (n=1 of 12 keratoplasty cases, 8.33%) were noted.</p><p><strong>Conclusion: </strong>NLPC may especially be useful in the eyes with a large vessel arborising within stroma. Lack of comparison with other treatment options leading to inflated safety and efficacy profile of NLPC is the major limitation of this study.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"10 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11877233/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2024-001734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Frequency doubling of neodymium-doped yttrium aluminum garnet (Nd-YAG) laser results in emission of photocoagulating 532 nm light compared with photolytic 1064 nm emission. The ergonomic benefits of solid-state lasers led to replacement of older coagulating lasers in ophthalmic centres by frequency-doubled Nd-YAG laser. Our study aims to evaluate safety and efficacy of frequency-doubled Nd-YAG laser for photocoagulation of corneal neovascularisation (NLPC).

Methods: 30 quiet eyes of 28 patients with superficial, mid-stromal and deep stromal inactive corneal neovascularisation were subjected to laser photocoagulation. Resolution of vessels, procedural complications and survival of subsequent corneal grafts were monitored for 3 months. Anterior segment fluorescein angiography (AS-FA) was performed in six eyes to confirm the cessation of blood flow.

Results: 20 eyes (66.66%) had complete resolution of neovascularisation. 13 cases of superficial (92.86%) and 6 cases of mid-stromal neovascularisation (75%) showed significant resolution, compared with 1 case of deep neovascularisation (12.5%). Minimal corneal burn (n=4, 13.33%), iris holes (n=3, 10%), anterior chamber bubbles (n=5, 16.67%), self-resolving intrastromal bleed (n=2, 6.67%) and graft-host junctional wound leak (n=1 of 12 keratoplasty cases, 8.33%) were noted.

Conclusion: NLPC may especially be useful in the eyes with a large vessel arborising within stroma. Lack of comparison with other treatment options leading to inflated safety and efficacy profile of NLPC is the major limitation of this study.

倍频Nd-YAG激光光凝治疗不同类型角膜新生血管(NLPC)的安全性和有效性:一项前瞻性研究。
目的:将掺钕钇铝石榴石(Nd-YAG)激光器的频率提高一倍,使其发射光凝532 nm的光,而不是光溶1064 nm的光。固体激光器对人体工程学的好处导致眼科中心用倍频Nd-YAG激光器取代旧的凝固激光器。本研究旨在评价倍频Nd-YAG激光光凝角膜新生血管(NLPC)的安全性和有效性。方法:对28例浅、中、深间质无活性角膜新生血管患者30只静眼进行激光光凝治疗。血管溶解、手术并发症及后续角膜移植存活监测3个月。对6只眼进行前段荧光素血管造影(AS-FA)以确认血流停止。结果:20只眼(66.66%)新生血管完全消退。浅表新生血管13例(92.86%),中基质新生血管6例(75%),深部新生血管1例(12.5%)。最小角膜烧伤(n=4, 13.33%)、虹膜穿孔(n=3, 10%)、前房气泡(n=5, 16.67%)、自解性角膜间出血(n=2, 6.67%)和移植物-载体结缔组织创面渗漏(12例角膜移植中n=1, 8.33%)。结论:NLPC对间质内有大血管的眼睛尤其有用。缺乏与其他治疗方案的比较,导致NLPC的安全性和有效性被夸大,这是本研究的主要局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Open Ophthalmology
BMJ Open Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
4.20%
发文量
104
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信