Graphene-Based Pressure Sensor Application in Non-Invasive Pulse Wave Velocity Continuous Estimation

IF 6.4 3区 材料科学 Q1 MATERIALS SCIENCE, MULTIDISCIPLINARY
Irene Buraioli, Stefania Vitale, Andrea Valerio, Alessandro Sanginario, Dario Leone, Sabrina Conoci, Artur Ciesielski, Alberto Milan, Danilo Demarchi, Paolo Samorì
{"title":"Graphene-Based Pressure Sensor Application in Non-Invasive Pulse Wave Velocity Continuous Estimation","authors":"Irene Buraioli,&nbsp;Stefania Vitale,&nbsp;Andrea Valerio,&nbsp;Alessandro Sanginario,&nbsp;Dario Leone,&nbsp;Sabrina Conoci,&nbsp;Artur Ciesielski,&nbsp;Alberto Milan,&nbsp;Danilo Demarchi,&nbsp;Paolo Samorì","doi":"10.1002/admt.202400876","DOIUrl":null,"url":null,"abstract":"<p>Monitoring the cardiovascular health of patients and early diagnosis of heart diseases are highly sought after as they can represent a true cornerstone in tomorrow's healthcare surveillance. Here, an unprecedented non-invasive device prototype is reported for pulse wave velocity (PWV) measurement based on a piezoelectric graphene pressure sensor. PWV is a critical health indicator that estimates arterial stiffness by measuring the velocity of arterial pulse flow through the circulatory system. The sensor incorporates advanced electronic components and data analysis tools, enabling the measurement of pulse transit time (PTT), that is the time required for the pulse wave to travel between carotid and femoral artery sites. Significantly, the outcomes obtained through the novel method, which involved monitoring 10 patients within clinical environment, show statistical similarity to results obtained using established technology for the PWV estimation such as SphygmoCor. In particular, the mean difference between measurements done with the two techniques resulted in 0.1 m s<sup>−1</sup>, that is &lt;2%, underscoring the reliability of the novel device. The technology holds big promise for enhancing cardiovascular healthcare delivery: it is wearable, potentially exploitable by a non-expert user, and it needs to be powered with just 0.2 V, thus it can become compatible even with applications in point-of-care settings.</p>","PeriodicalId":7292,"journal":{"name":"Advanced Materials Technologies","volume":"10 5","pages":""},"PeriodicalIF":6.4000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/admt.202400876","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials Technologies","FirstCategoryId":"88","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/admt.202400876","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Monitoring the cardiovascular health of patients and early diagnosis of heart diseases are highly sought after as they can represent a true cornerstone in tomorrow's healthcare surveillance. Here, an unprecedented non-invasive device prototype is reported for pulse wave velocity (PWV) measurement based on a piezoelectric graphene pressure sensor. PWV is a critical health indicator that estimates arterial stiffness by measuring the velocity of arterial pulse flow through the circulatory system. The sensor incorporates advanced electronic components and data analysis tools, enabling the measurement of pulse transit time (PTT), that is the time required for the pulse wave to travel between carotid and femoral artery sites. Significantly, the outcomes obtained through the novel method, which involved monitoring 10 patients within clinical environment, show statistical similarity to results obtained using established technology for the PWV estimation such as SphygmoCor. In particular, the mean difference between measurements done with the two techniques resulted in 0.1 m s−1, that is <2%, underscoring the reliability of the novel device. The technology holds big promise for enhancing cardiovascular healthcare delivery: it is wearable, potentially exploitable by a non-expert user, and it needs to be powered with just 0.2 V, thus it can become compatible even with applications in point-of-care settings.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Advanced Materials Technologies
Advanced Materials Technologies Materials Science-General Materials Science
CiteScore
10.20
自引率
4.40%
发文量
566
期刊介绍: Advanced Materials Technologies Advanced Materials Technologies is the new home for all technology-related materials applications research, with particular focus on advanced device design, fabrication and integration, as well as new technologies based on novel materials. It bridges the gap between fundamental laboratory research and industry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信