CFD Validation of Forced and Natural Convection for the Open Phase of IAEA Benchmark CRP-I31038

IF 2.6 4区 综合性期刊 Q2 MULTIDISCIPLINARY SCIENCES
Abdalla Batta, Andreas G. Class
{"title":"CFD Validation of Forced and Natural Convection for the Open Phase of IAEA Benchmark CRP-I31038","authors":"Abdalla Batta,&nbsp;Andreas G. Class","doi":"10.1007/s13369-024-09480-x","DOIUrl":null,"url":null,"abstract":"<div><p>The goal of the IAEA Coordinated Research Project “Benchmark of Transition from Forced to Natural Circulation Experiment with Heavy Liquid Metal Loop” (CRP—I31038) is to develop Member State advanced fast reactor analytical capabilities for simulation and design using system, CFD, and subchannel analysis codes. Here, CFD validation employing the commercial CFD code Star CCM + applied to the fuel pin simulator for forced and natural convection cases in the open phase is presented. Experimental data are provided in the benchmark specification provided by ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development) for the NACIE-UP facility (NAtural CIrculation Experiment-UPgrade). Considered is the fuel pin simulator with 19 pins, each consisting of a preheated lower section and heated upper sections, respectively. Three configurations: (i) all pins heated, (ii) inner 7 pins heated and (iii) asymmetric heating, are studied. For each heating configuration data for forced and natural convection are provided. Here, case (i) is studied. Temperatures at three planes are measured near the inlet, in the middle and near the end of the heated section, respectively. In addition, the axial temperature along the wall of one fuel pin simulator (in second row) is measured so that in total 67 thermocouples measure fluid and wall temperatures for validation purposes. The validation confirms that the thermohydraulic inside the fuel pin simulator can be simulated with a good accuracy. Applied is a polyhedral mesh with 2 prism layers, the k-omega SST model with all all-wall treatment and order unity y + values. Moreover, a grid-sensitivity, the importance of conjugate heat transfer inside the fuel pin simulators and the wrapper are studied. The studies indicate that it is possible to implement further simplifications without corrupting the accuracy of the simulation to reduce computational effort.</p></div>","PeriodicalId":54354,"journal":{"name":"Arabian Journal for Science and Engineering","volume":"50 5","pages":"3409 - 3415"},"PeriodicalIF":2.6000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s13369-024-09480-x.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arabian Journal for Science and Engineering","FirstCategoryId":"103","ListUrlMain":"https://link.springer.com/article/10.1007/s13369-024-09480-x","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The goal of the IAEA Coordinated Research Project “Benchmark of Transition from Forced to Natural Circulation Experiment with Heavy Liquid Metal Loop” (CRP—I31038) is to develop Member State advanced fast reactor analytical capabilities for simulation and design using system, CFD, and subchannel analysis codes. Here, CFD validation employing the commercial CFD code Star CCM + applied to the fuel pin simulator for forced and natural convection cases in the open phase is presented. Experimental data are provided in the benchmark specification provided by ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development) for the NACIE-UP facility (NAtural CIrculation Experiment-UPgrade). Considered is the fuel pin simulator with 19 pins, each consisting of a preheated lower section and heated upper sections, respectively. Three configurations: (i) all pins heated, (ii) inner 7 pins heated and (iii) asymmetric heating, are studied. For each heating configuration data for forced and natural convection are provided. Here, case (i) is studied. Temperatures at three planes are measured near the inlet, in the middle and near the end of the heated section, respectively. In addition, the axial temperature along the wall of one fuel pin simulator (in second row) is measured so that in total 67 thermocouples measure fluid and wall temperatures for validation purposes. The validation confirms that the thermohydraulic inside the fuel pin simulator can be simulated with a good accuracy. Applied is a polyhedral mesh with 2 prism layers, the k-omega SST model with all all-wall treatment and order unity y + values. Moreover, a grid-sensitivity, the importance of conjugate heat transfer inside the fuel pin simulators and the wrapper are studied. The studies indicate that it is possible to implement further simplifications without corrupting the accuracy of the simulation to reduce computational effort.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Arabian Journal for Science and Engineering
Arabian Journal for Science and Engineering MULTIDISCIPLINARY SCIENCES-
CiteScore
5.70
自引率
3.40%
发文量
993
期刊介绍: King Fahd University of Petroleum & Minerals (KFUPM) partnered with Springer to publish the Arabian Journal for Science and Engineering (AJSE). AJSE, which has been published by KFUPM since 1975, is a recognized national, regional and international journal that provides a great opportunity for the dissemination of research advances from the Kingdom of Saudi Arabia, MENA and the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信