Resonant behavior and stability of a linear three-mirror cavity

IF 3.6 3区 物理与天体物理 Q2 ASTRONOMY & ASTROPHYSICS
Paul Stevens, Vincent Loriette, Manuel Andia, François Glotin, Angélique Lartaux-Vollard, Nicolas Leroy and Aymeric van de Walle
{"title":"Resonant behavior and stability of a linear three-mirror cavity","authors":"Paul Stevens, Vincent Loriette, Manuel Andia, François Glotin, Angélique Lartaux-Vollard, Nicolas Leroy and Aymeric van de Walle","doi":"10.1088/1361-6382/adb827","DOIUrl":null,"url":null,"abstract":"The implementation of Fabry–Perot cavities in gravitational-wave detectors has been pivotal to improving their sensitivity, allowing the observation of an increasing number of cosmological events with higher signal-to-noise ratio. Notably, Fabry–Perot cavities play a key role in the frequency-dependent squeezing technique, which provides a reduction of quantum noise over the whole observation frequency spectrum. In this paper, we first present how the adaptability of resonance properties of linear three-mirror cavities, and the real-time control we could have on it, would be interesting for frequency-dependant squeezing in future detectors, especially for Einstein Telescope project. In this view, we develop a complete model to describe the stability behavior and the properties of transmitted and reflected fields of a linear three-mirror cavity aiming to be used for design purposes. In particular, simulations are carried out to show the evolution of the characteristic double resonance peak they can show-off, which is one of the key features of this system, as a function of cavity parameters. We show that the double-peak shape is almost freely adjustable, either in terms of spacing between maxima, their relative amplitude and intrinsic width. This is made possible by changing the mirrors’ reflectivity coefficients and the sub-cavities microscopic/macroscopic lengths. However, the amount of achievable realistic configurations is limited by the stability conditions of the cavity. In particular, if the two sub-cavities do not have the same macroscopic length, it could be difficult to obtain a stable three-mirror cavity. Different geometries have been studied to obtain a stable system.","PeriodicalId":10282,"journal":{"name":"Classical and Quantum Gravity","volume":"55 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Classical and Quantum Gravity","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1088/1361-6382/adb827","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ASTRONOMY & ASTROPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

The implementation of Fabry–Perot cavities in gravitational-wave detectors has been pivotal to improving their sensitivity, allowing the observation of an increasing number of cosmological events with higher signal-to-noise ratio. Notably, Fabry–Perot cavities play a key role in the frequency-dependent squeezing technique, which provides a reduction of quantum noise over the whole observation frequency spectrum. In this paper, we first present how the adaptability of resonance properties of linear three-mirror cavities, and the real-time control we could have on it, would be interesting for frequency-dependant squeezing in future detectors, especially for Einstein Telescope project. In this view, we develop a complete model to describe the stability behavior and the properties of transmitted and reflected fields of a linear three-mirror cavity aiming to be used for design purposes. In particular, simulations are carried out to show the evolution of the characteristic double resonance peak they can show-off, which is one of the key features of this system, as a function of cavity parameters. We show that the double-peak shape is almost freely adjustable, either in terms of spacing between maxima, their relative amplitude and intrinsic width. This is made possible by changing the mirrors’ reflectivity coefficients and the sub-cavities microscopic/macroscopic lengths. However, the amount of achievable realistic configurations is limited by the stability conditions of the cavity. In particular, if the two sub-cavities do not have the same macroscopic length, it could be difficult to obtain a stable three-mirror cavity. Different geometries have been studied to obtain a stable system.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Classical and Quantum Gravity
Classical and Quantum Gravity 物理-天文与天体物理
CiteScore
7.00
自引率
8.60%
发文量
301
审稿时长
2-4 weeks
期刊介绍: Classical and Quantum Gravity is an established journal for physicists, mathematicians and cosmologists in the fields of gravitation and the theory of spacetime. The journal is now the acknowledged world leader in classical relativity and all areas of quantum gravity.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信