A Pilot Study of Computed Tomography Simulator Downtime at an African Cancer Conference: Survey Results From AORTIC 2023.

IF 6.4 1区 医学 Q1 ONCOLOGY
Michael P Dykstra, Tucker J Netherton, Nwamaka N Lasebikan, Diane A Ndoli, Solomon Kibudde, Bello A Mohammed, Peter Balter, Adam D Melancon, Donald Roberts, Jeniffer L Shah, Julianna Coleman, Mercy N Kitonyi, Abba Mallum, Graeme L Lazarus, Angela K Waweru, William Shaw, Sarah T Hawley, Lauren P Wallner, Laurence E Court
{"title":"A Pilot Study of Computed Tomography Simulator Downtime at an African Cancer Conference: Survey Results From AORTIC 2023.","authors":"Michael P Dykstra, Tucker J Netherton, Nwamaka N Lasebikan, Diane A Ndoli, Solomon Kibudde, Bello A Mohammed, Peter Balter, Adam D Melancon, Donald Roberts, Jeniffer L Shah, Julianna Coleman, Mercy N Kitonyi, Abba Mallum, Graeme L Lazarus, Angela K Waweru, William Shaw, Sarah T Hawley, Lauren P Wallner, Laurence E Court","doi":"10.1016/j.ijrobp.2025.02.019","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Computed tomography (CT) simulation is required for centers performing 3-dimensional conformal radiation therapy and intensity modulated radiation therapy. Therefore, CT simulator downtime is likely to lead to delays in patient care. We sought to characterize CT simulator downtime within the African context.</p><p><strong>Methods and materials: </strong>A pilot clinician survey was developed to evaluate CT simulator downtime frequency, causes, and workflow impact over the last year. It was distributed to African Organization for Research and Training in Cancer Conference attendees in November 2023 and through radiation therapy networks on the African continent. Descriptive statistics were used to summarize data.</p><p><strong>Results: </strong>Responses were obtained for 22 CT scanners in 16 centers across 9 African countries. Nigeria (n = 6) and South Africa (n = 3) had the most centers represented. Most centers (n = 10, 63%) had a single CT scanner capable of simulation, 5 (31%) had 2, and 1 (6%) had 3 scanners. For the 19 CT simulators with downtime information available, 11 (58%) were down for at least 15 days in the last year. Median downtime per episode was 3.5 days (IQR, 1-9.75 days). Three CT simulators were down all year, 2 of which were the only CT simulator at their respective centers. CT simulators were down because of intrinsic causes for median 8 days (IQR, 3-37.5 days) and extrinsic causes for median 1 day (IQR, 0-7.5 days). Most machines (n = 17, 77%) were under an active maintenance contract. Most centers (n = 11, 69%) lacked access to an alternate CT scanner for simulation during downtime, whereas 3 (19%) maintained normal workflow.</p><p><strong>Conclusions: </strong>CT simulator downtime is highly variable across the African continent and can cause significant disruptions in radiation therapy treatment at some centers. Intrinsic causes led to most downtime. These results suggest reducing CT simulator downtime frequency and duration or implementing simulation-free workflows may decrease patient delays.</p>","PeriodicalId":14215,"journal":{"name":"International Journal of Radiation Oncology Biology Physics","volume":" ","pages":""},"PeriodicalIF":6.4000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Oncology Biology Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ijrobp.2025.02.019","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Computed tomography (CT) simulation is required for centers performing 3-dimensional conformal radiation therapy and intensity modulated radiation therapy. Therefore, CT simulator downtime is likely to lead to delays in patient care. We sought to characterize CT simulator downtime within the African context.

Methods and materials: A pilot clinician survey was developed to evaluate CT simulator downtime frequency, causes, and workflow impact over the last year. It was distributed to African Organization for Research and Training in Cancer Conference attendees in November 2023 and through radiation therapy networks on the African continent. Descriptive statistics were used to summarize data.

Results: Responses were obtained for 22 CT scanners in 16 centers across 9 African countries. Nigeria (n = 6) and South Africa (n = 3) had the most centers represented. Most centers (n = 10, 63%) had a single CT scanner capable of simulation, 5 (31%) had 2, and 1 (6%) had 3 scanners. For the 19 CT simulators with downtime information available, 11 (58%) were down for at least 15 days in the last year. Median downtime per episode was 3.5 days (IQR, 1-9.75 days). Three CT simulators were down all year, 2 of which were the only CT simulator at their respective centers. CT simulators were down because of intrinsic causes for median 8 days (IQR, 3-37.5 days) and extrinsic causes for median 1 day (IQR, 0-7.5 days). Most machines (n = 17, 77%) were under an active maintenance contract. Most centers (n = 11, 69%) lacked access to an alternate CT scanner for simulation during downtime, whereas 3 (19%) maintained normal workflow.

Conclusions: CT simulator downtime is highly variable across the African continent and can cause significant disruptions in radiation therapy treatment at some centers. Intrinsic causes led to most downtime. These results suggest reducing CT simulator downtime frequency and duration or implementing simulation-free workflows may decrease patient delays.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
11.00
自引率
7.10%
发文量
2538
审稿时长
6.6 weeks
期刊介绍: International Journal of Radiation Oncology • Biology • Physics (IJROBP), known in the field as the Red Journal, publishes original laboratory and clinical investigations related to radiation oncology, radiation biology, medical physics, and both education and health policy as it relates to the field. This journal has a particular interest in original contributions of the following types: prospective clinical trials, outcomes research, and large database interrogation. In addition, it seeks reports of high-impact innovations in single or combined modality treatment, tumor sensitization, normal tissue protection (including both precision avoidance and pharmacologic means), brachytherapy, particle irradiation, and cancer imaging. Technical advances related to dosimetry and conformal radiation treatment planning are of interest, as are basic science studies investigating tumor physiology and the molecular biology underlying cancer and normal tissue radiation response.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信