Ethylated phosphorylcholine – a new marker for ethanol consumption: A proof of concept

IF 1.8 Q4 TOXICOLOGY
Catalina Dumitrascu , Elias Iturrospe , Celine Gys , Matthias Van Puymbroeck , Patrick Timmermans , Els Scheir , Werner Jacobs , Hugo Neels , Adrian Covaci , Alexander L.N. Van Nuijs
{"title":"Ethylated phosphorylcholine – a new marker for ethanol consumption: A proof of concept","authors":"Catalina Dumitrascu ,&nbsp;Elias Iturrospe ,&nbsp;Celine Gys ,&nbsp;Matthias Van Puymbroeck ,&nbsp;Patrick Timmermans ,&nbsp;Els Scheir ,&nbsp;Werner Jacobs ,&nbsp;Hugo Neels ,&nbsp;Adrian Covaci ,&nbsp;Alexander L.N. Van Nuijs","doi":"10.1016/j.toxac.2025.01.031","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><div>During in vitro exposure of HepaRG liver cells to ethanol, untargeted metabolomics revealed the formation of ethylated phosphorylcholine (EtOChoP), a metabolite which was not reported before <span><span>[1]</span></span>, <span><span>[2]</span></span>. To determine its role as a potential new biomarker for alcohol use and its detection window, a single alcohol exposure study was performed on a teetotaler. Whole blood, plasma, and serum were analysed for EtOChoP and compared with levels of established alcohol use biomarkers, such as phosphatidylethanol 16: 0/18: 1 (PEth), ethyl glucuronide (EtG), ethyl sulphate (EtS), and ethanol (EtOH) in the same samples.</div></div><div><h3>Method</h3><div>For the analysis of EtOChoP in whole blood, serum, and plasma, a 96-well microplate liquid-liquid extraction was developed and validated. Briefly, 100<!--> <!-->μL sample and 250<!--> <!-->μL of ice cold (−80°<!--> <!-->C) methanol were added, and subsequently spiked with EtOChoP-D5, internal standard. After vortexing, the 96-well plate was placed on ice, sonicated briefly and left to equilibrate for 20<!--> <!-->min. After centrifugation, the supernatant was filtered through a 96-well filtration plate and further evaporated to dryness using nitrogen. The dried extract was reconstituted in 100<!--> <!-->μL MeOH: H2O(1: 1) and 5<!--> <!-->μL was injected in an Agilent 1290 Infinity LC/6495<!--> <!-->C triple quadrupole MS using a Restek Force Biphenyl column set at 60°<!--> <!-->C. The mobile phase was a mixture of water and 0.1% formic acid as solvent A, and methanol and 0.1% formic acid, as solvent B. The total run time was 8<!--> <!-->min. The MS/MS source was operated in positive mode. The monitored m/z transitions were 212.1 &gt;<!--> <!-->126.0 (quantifier) and 86.1, 98.1(qualifiers) for EtOChoP, and 217.1 &gt;<!--> <!-->126.0 (quantifier) and 86.1(qualifier) for EtOChoP-D5.</div><div>Single alcohol exposure study design: after being abstinent for five months, a female volunteer was instructed to abstain from food and beverages (including water) for 12<!--> <!-->hours prior to the experiment. The volunteer consumed a dose of 0.5<!--> <!-->g ethanol per kilogram body weight in one minute as a 20% (w/v) ethanol solution in water. Whole blood, plasma, and serum were collected at point T0 (before the drinking), T30, T60, T80, T100, T120, T140, T160, T180, T240<!--> <!-->min and day 1, 2, 5 and 8 after the drinking experiment.</div></div><div><h3>Results</h3><div>EtOH, PEth, EtG and EtS, EtOChoP were not detected at T0 in all matrices. EtOH in whole blood showed an increase to 0.76<!--> <!-->g/L (T100), followed by a decrease to 0.32<!--> <!-->g/L at T240. EtOChoP in whole blood showed an increase in concentration from 0.73<!--> <!-->ng/mL (T30) to 1.57<!--> <!-->ng/mL (T80) followed by a decrease to 0.55<!--> <!-->ng/mL (T240). Even though, serum samples showed a higher concentration, it followed the same pattern as whole blood and plasma samples, an increase from T30 to T80 followed by a decrease until T240. The following days (D1, D2, D5 and D8), EtOH, EtG, EtS and EtOChoP were not detected in any of the matrices. PEth showed an increase in concentration from 6.6<!--> <!-->ng/mL (T30) to 18<!--> <!-->ng/mL (D1), followed by a decrease in D2, D5 and D8. Nevertheless, the concentrations of PEth did not exceed the 20<!--> <!-->ng/mL cutoff value, compatible with abstinence/low alcohol consumption <span><span>[3]</span></span>.</div></div><div><h3>Conclusion</h3><div>This proof of concept study shows that EtOChoP is detectable in different matrices after a single alcohol consumption, which demonstrates EtOChoP can be a promising new alcohol biomarker. The presence of EtOChoP up to 240<!--> <!-->min and its absence in the following day(s) shows that it could be a short-term alcohol biomarker, together with EtOH, EtG and EtS. Nevertheless, future studies are needed to determine its true potential as an alcohol biomarker, as this study looked only at a controlled single alcohol exposure.</div></div>","PeriodicalId":23170,"journal":{"name":"Toxicologie Analytique et Clinique","volume":"37 1","pages":"Pages S23-S24"},"PeriodicalIF":1.8000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Toxicologie Analytique et Clinique","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352007825000319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aim

During in vitro exposure of HepaRG liver cells to ethanol, untargeted metabolomics revealed the formation of ethylated phosphorylcholine (EtOChoP), a metabolite which was not reported before [1], [2]. To determine its role as a potential new biomarker for alcohol use and its detection window, a single alcohol exposure study was performed on a teetotaler. Whole blood, plasma, and serum were analysed for EtOChoP and compared with levels of established alcohol use biomarkers, such as phosphatidylethanol 16: 0/18: 1 (PEth), ethyl glucuronide (EtG), ethyl sulphate (EtS), and ethanol (EtOH) in the same samples.

Method

For the analysis of EtOChoP in whole blood, serum, and plasma, a 96-well microplate liquid-liquid extraction was developed and validated. Briefly, 100 μL sample and 250 μL of ice cold (−80° C) methanol were added, and subsequently spiked with EtOChoP-D5, internal standard. After vortexing, the 96-well plate was placed on ice, sonicated briefly and left to equilibrate for 20 min. After centrifugation, the supernatant was filtered through a 96-well filtration plate and further evaporated to dryness using nitrogen. The dried extract was reconstituted in 100 μL MeOH: H2O(1: 1) and 5 μL was injected in an Agilent 1290 Infinity LC/6495 C triple quadrupole MS using a Restek Force Biphenyl column set at 60° C. The mobile phase was a mixture of water and 0.1% formic acid as solvent A, and methanol and 0.1% formic acid, as solvent B. The total run time was 8 min. The MS/MS source was operated in positive mode. The monitored m/z transitions were 212.1 > 126.0 (quantifier) and 86.1, 98.1(qualifiers) for EtOChoP, and 217.1 > 126.0 (quantifier) and 86.1(qualifier) for EtOChoP-D5.
Single alcohol exposure study design: after being abstinent for five months, a female volunteer was instructed to abstain from food and beverages (including water) for 12 hours prior to the experiment. The volunteer consumed a dose of 0.5 g ethanol per kilogram body weight in one minute as a 20% (w/v) ethanol solution in water. Whole blood, plasma, and serum were collected at point T0 (before the drinking), T30, T60, T80, T100, T120, T140, T160, T180, T240 min and day 1, 2, 5 and 8 after the drinking experiment.

Results

EtOH, PEth, EtG and EtS, EtOChoP were not detected at T0 in all matrices. EtOH in whole blood showed an increase to 0.76 g/L (T100), followed by a decrease to 0.32 g/L at T240. EtOChoP in whole blood showed an increase in concentration from 0.73 ng/mL (T30) to 1.57 ng/mL (T80) followed by a decrease to 0.55 ng/mL (T240). Even though, serum samples showed a higher concentration, it followed the same pattern as whole blood and plasma samples, an increase from T30 to T80 followed by a decrease until T240. The following days (D1, D2, D5 and D8), EtOH, EtG, EtS and EtOChoP were not detected in any of the matrices. PEth showed an increase in concentration from 6.6 ng/mL (T30) to 18 ng/mL (D1), followed by a decrease in D2, D5 and D8. Nevertheless, the concentrations of PEth did not exceed the 20 ng/mL cutoff value, compatible with abstinence/low alcohol consumption [3].

Conclusion

This proof of concept study shows that EtOChoP is detectable in different matrices after a single alcohol consumption, which demonstrates EtOChoP can be a promising new alcohol biomarker. The presence of EtOChoP up to 240 min and its absence in the following day(s) shows that it could be a short-term alcohol biomarker, together with EtOH, EtG and EtS. Nevertheless, future studies are needed to determine its true potential as an alcohol biomarker, as this study looked only at a controlled single alcohol exposure.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
33.30%
发文量
393
审稿时长
47 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信