{"title":"The effect of using automatic meter reading system in electricity distribution systems on reducing non-technical losses: The case of Bitlis province in Turkey","authors":"Sabir Rüstemli ,&nbsp;Yunus Kocaman ,&nbsp;Behçet Kocaman ,&nbsp;Gökhan Şahin ,&nbsp;Wilfried van Sark","doi":"10.1016/j.esr.2025.101674","DOIUrl":null,"url":null,"abstract":"<div><div>Energy losses, both technical and non-technical, are incurred during the transfer of electrical energy from the power plant to the customer. Technical energy losses are evident since they result from the properties of materials. Detecting non-technical energy losses is challenging due to their origin in usage. Some of the non-technical energy losses are caused by meter readings. Electricity meters, which are used to record the electrical energy consumed in electricity distribution networks, are spread over a wide area. Hence, it is unfeasible to gather the data obtained from electricity meters without any errors. Furthermore, the absence of electrical energy monitoring is a significant issue. The automatic meter reading system (AMRS) provides a cost-effective solution to these issues. This study examines the structure, benefits, and implementation challenges of an autonomous meter reading system. This study examines the impact of utilizing power line communication (PLC) meters in the automatic meter reading system application on reducing non-technical energy losses in electricity distribution networks. This study employed energy usage data from Bitlis province. The annual loss and leakage rates presume that the proportion of technical energy losses remains constant compared to the previous year. The examination revealed that the loss and leakage rate was 36.28 % in 2019, 35.10 % in 2020, 29.82 % in 2021, and 25.32 % in 2022. Between 2019 and 2022, the decline in loss and leakage rates is attributed to a reduction in non-technical energy losses. The automatic meter reading system is determined to have a substantial impact on reducing non-technical energy losses in electricity distribution networks. Since the energy needs of countries are increasing day by day, it requires more efficient use of energy. It will lead to more efficient use of energy by reducing non-technical energy losses. In the study, the contribution of automatic meter reading systems to reducing non-technical energy losses is emphasized. The study is valuable as it sets an example for future studies.</div></div>","PeriodicalId":11546,"journal":{"name":"Energy Strategy Reviews","volume":"58 ","pages":"Article 101674"},"PeriodicalIF":7.9000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Strategy Reviews","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2211467X25000379","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Energy losses, both technical and non-technical, are incurred during the transfer of electrical energy from the power plant to the customer. Technical energy losses are evident since they result from the properties of materials. Detecting non-technical energy losses is challenging due to their origin in usage. Some of the non-technical energy losses are caused by meter readings. Electricity meters, which are used to record the electrical energy consumed in electricity distribution networks, are spread over a wide area. Hence, it is unfeasible to gather the data obtained from electricity meters without any errors. Furthermore, the absence of electrical energy monitoring is a significant issue. The automatic meter reading system (AMRS) provides a cost-effective solution to these issues. This study examines the structure, benefits, and implementation challenges of an autonomous meter reading system. This study examines the impact of utilizing power line communication (PLC) meters in the automatic meter reading system application on reducing non-technical energy losses in electricity distribution networks. This study employed energy usage data from Bitlis province. The annual loss and leakage rates presume that the proportion of technical energy losses remains constant compared to the previous year. The examination revealed that the loss and leakage rate was 36.28 % in 2019, 35.10 % in 2020, 29.82 % in 2021, and 25.32 % in 2022. Between 2019 and 2022, the decline in loss and leakage rates is attributed to a reduction in non-technical energy losses. The automatic meter reading system is determined to have a substantial impact on reducing non-technical energy losses in electricity distribution networks. Since the energy needs of countries are increasing day by day, it requires more efficient use of energy. It will lead to more efficient use of energy by reducing non-technical energy losses. In the study, the contribution of automatic meter reading systems to reducing non-technical energy losses is emphasized. The study is valuable as it sets an example for future studies.
在配电系统中使用自动抄表系统对减少非技术性损失的影响:土耳其比特里斯省的案例
电能从发电厂转移到用户的过程中产生了技术和非技术的能量损失。技术能量损失是显而易见的,因为它们是由材料的特性造成的。由于非技术能量损失的来源,检测是非技术能量损失是具有挑战性的。一些非技术能量损失是由仪表读数引起的。电表用于记录配电网络中消耗的电能,分布在广泛的地区。因此,不可能毫无误差地收集电表所获得的数据。此外,缺乏电能监测是一个重大问题。自动抄表系统(AMRS)为这些问题提供了一个经济有效的解决方案。本研究探讨了自动抄表系统的结构、好处和实施挑战。本研究探讨在自动抄表系统中使用电力线通讯(PLC)电表对减少配电网非技术能量损失的影响。本研究采用了Bitlis省的能源使用数据。年损失率和泄漏率假定技术能量损失的比例与前一年相比保持不变。检查结果显示,2019年的损失率为36.28%,2020年为35.10%,2021年为29.82%,2022年为25.32%。在2019年至2022年期间,损失和泄漏率的下降归因于非技术能源损失的减少。自动抄表系统被认为对减少配电网的非技术能量损失有重大影响。由于各国的能源需求日益增加,因此需要更有效地利用能源。通过减少非技术能源损失,它将导致更有效地利用能源。在研究中,强调了自动抄表系统对减少非技术能源损失的贡献。该研究为今后的研究树立了榜样,具有一定的价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy Strategy Reviews
Energy Strategy Reviews Energy-Energy (miscellaneous)
CiteScore
12.80
自引率
4.90%
发文量
167
审稿时长
40 weeks
期刊介绍: Energy Strategy Reviews is a gold open access journal that provides authoritative content on strategic decision-making and vision-sharing related to society''s energy needs. Energy Strategy Reviews publishes: • Analyses • Methodologies • Case Studies • Reviews And by invitation: • Report Reviews • Viewpoints
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信