Detectability in Scalp EEGs of Epileptic Spikes Emitted from Brain Electrical Sources of Different Sizes and Locations: A Simulation Study Using Realistic Head Models of Elderly Adults.

Makoto Takenaka, Mark E Pflieger, Tomokatsu Hori, Yudai Iwama, Jumpei Matsumoto, Tsuyoshi Setogawa, Atsushi Shirasawa, Hiroshi Nishimaru, Hisao Nishijo
{"title":"Detectability in Scalp EEGs of Epileptic Spikes Emitted from Brain Electrical Sources of Different Sizes and Locations: A Simulation Study Using Realistic Head Models of Elderly Adults.","authors":"Makoto Takenaka, Mark E Pflieger, Tomokatsu Hori, Yudai Iwama, Jumpei Matsumoto, Tsuyoshi Setogawa, Atsushi Shirasawa, Hiroshi Nishimaru, Hisao Nishijo","doi":"10.1177/15500594251323625","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background.</i> Epilepsy is prevalent in the elderly, whose brain morphologies and skull electrical characteristics differ from those of younger adults. Here, using a multivariate definition of signal-to-noise ratio (SNR), we explored the detectability of epileptic spikes in scalp EEG measurements in elderly by forward simulations of hypersynchronous spikes generated at 78 cortical regions of interest (ROIs) in the presence of background noise. <i>Methods.</i> Simulated electric potentials were measured at 18, 35, and 70 standard 10-20 electrode positions using three reference methods: infinity reference (INF), common average reference (CAR), and average mastoid reference (M1M2). MRIs of six elderly subjects were used to construct finite element method (FEM) models with age-adjusted skull conductivities. <i>Results.</i> SNRs of epileptic spikes increased with increasing sizes of the brain electrical source areas, although medial and deep brain regions such as the hippocampus showed lower SNRs, consistent with clinical findings. The SNRs were greater in the 70-channel dataset than in the 18-channel and 35-channel datasets, especially for ROIs located closer to the head surface. In addition, the SNRs were lower for the CAR and M1M2 references than for the ideal INF reference. Moreover, we found comparable results in the standard FEM heads with age-adjusted skull conductivities. <i>Conclusions.</i> The results provide insights for evaluating scalp EEG data in elderly patients with suspected epilepsy, and suggest that age-adjusted skull conductivity is an important factor for forward models in elderly adults, and that the standard FEM head with age-adjusted skull conductivity can be used when MRIs are not available.</p>","PeriodicalId":93940,"journal":{"name":"Clinical EEG and neuroscience","volume":" ","pages":"15500594251323625"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical EEG and neuroscience","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15500594251323625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Epilepsy is prevalent in the elderly, whose brain morphologies and skull electrical characteristics differ from those of younger adults. Here, using a multivariate definition of signal-to-noise ratio (SNR), we explored the detectability of epileptic spikes in scalp EEG measurements in elderly by forward simulations of hypersynchronous spikes generated at 78 cortical regions of interest (ROIs) in the presence of background noise. Methods. Simulated electric potentials were measured at 18, 35, and 70 standard 10-20 electrode positions using three reference methods: infinity reference (INF), common average reference (CAR), and average mastoid reference (M1M2). MRIs of six elderly subjects were used to construct finite element method (FEM) models with age-adjusted skull conductivities. Results. SNRs of epileptic spikes increased with increasing sizes of the brain electrical source areas, although medial and deep brain regions such as the hippocampus showed lower SNRs, consistent with clinical findings. The SNRs were greater in the 70-channel dataset than in the 18-channel and 35-channel datasets, especially for ROIs located closer to the head surface. In addition, the SNRs were lower for the CAR and M1M2 references than for the ideal INF reference. Moreover, we found comparable results in the standard FEM heads with age-adjusted skull conductivities. Conclusions. The results provide insights for evaluating scalp EEG data in elderly patients with suspected epilepsy, and suggest that age-adjusted skull conductivity is an important factor for forward models in elderly adults, and that the standard FEM head with age-adjusted skull conductivity can be used when MRIs are not available.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信