High-resolution and high-fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced-FOV multiplexed sensitivity encoding (3D-rFOV-MUSE).
IF 3 3区 医学Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
{"title":"High-resolution and high-fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced-FOV multiplexed sensitivity encoding (3D-rFOV-MUSE).","authors":"Chenglang Yuan, Shihui Chen, Liyuan Liang, Xiaorui Xu, Hailin Xiong, Yi Li, Tianbaige Liu, Nan-Kuei Chen, Hing-Chiu Chang","doi":"10.1002/mrm.30455","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop a 3D isotropic high-resolution and high-fidelity cervical spinal cord DTI technique for addressing the current challenges existing in 2D cervical spinal cord DTI.</p><p><strong>Methods: </strong>A 3D multi-shot DWI acquisition and reconstruction technique was developed by combining 3D multiplexed sensitivity encoding (3D-MUSE) with two reduced FOV techniques, termed 3D-rFOV-MUSE, to acquire 3D cervical spinal cord DTI data using a sagittal thin slab. A self-referenced 2D ghost correction method and a 2D navigator-based inter-shot phase correction were integrated into the reconstruction framework to simultaneously eliminate Nyquist ghost and aliasing artifacts. Cardiac triggering was used during data acquisition to minimize the influence of cerebrospinal fluid pulsation. In vivo experiments were conducted on five healthy subjects at a 1.5 T MRI scanner for evaluating the feasibility of 3D cervical spinal cord DTI using 3D-rFOV-MUSE in terms of geometric fidelity, reconstruction performance, and SNR efficiency.</p><p><strong>Results: </strong>A 3D-rFOV-MUSE can achieve high-resolution cervical spinal cord DTI at 1.0 mm isotropic resolution. The integration of reduced FOV and multi-shot acquisitions can improve the geometric fidelity of 3D cervical spinal cord DTI. Compared with routine 2D single-shot diffusion-weighed EPI (2D-ss-EPI), the proposed technique can mitigate through-plane partial volume effect and enable multi-planar data reformation for cervical spinal cord DTI, with effective reductions of distortions and improved signal-to-noise ratio.</p><p><strong>Conclusion: </strong>We demonstrated the feasibility of high-resolution and high-fidelity 3D cervical spinal cord DTI at 1.0 mm isotropic resolution using 3D-rFOV-MUSE technique, which may potentially improve the quantitative assessment of cervical spinal cord DTI biomarkers.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30455","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To develop a 3D isotropic high-resolution and high-fidelity cervical spinal cord DTI technique for addressing the current challenges existing in 2D cervical spinal cord DTI.
Methods: A 3D multi-shot DWI acquisition and reconstruction technique was developed by combining 3D multiplexed sensitivity encoding (3D-MUSE) with two reduced FOV techniques, termed 3D-rFOV-MUSE, to acquire 3D cervical spinal cord DTI data using a sagittal thin slab. A self-referenced 2D ghost correction method and a 2D navigator-based inter-shot phase correction were integrated into the reconstruction framework to simultaneously eliminate Nyquist ghost and aliasing artifacts. Cardiac triggering was used during data acquisition to minimize the influence of cerebrospinal fluid pulsation. In vivo experiments were conducted on five healthy subjects at a 1.5 T MRI scanner for evaluating the feasibility of 3D cervical spinal cord DTI using 3D-rFOV-MUSE in terms of geometric fidelity, reconstruction performance, and SNR efficiency.
Results: A 3D-rFOV-MUSE can achieve high-resolution cervical spinal cord DTI at 1.0 mm isotropic resolution. The integration of reduced FOV and multi-shot acquisitions can improve the geometric fidelity of 3D cervical spinal cord DTI. Compared with routine 2D single-shot diffusion-weighed EPI (2D-ss-EPI), the proposed technique can mitigate through-plane partial volume effect and enable multi-planar data reformation for cervical spinal cord DTI, with effective reductions of distortions and improved signal-to-noise ratio.
Conclusion: We demonstrated the feasibility of high-resolution and high-fidelity 3D cervical spinal cord DTI at 1.0 mm isotropic resolution using 3D-rFOV-MUSE technique, which may potentially improve the quantitative assessment of cervical spinal cord DTI biomarkers.
期刊介绍:
Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.