Management of fracture and displacement of a previously successful bilateral transconjunctival ab-externo XEN gel stent: a case report.

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY
Qi Zhang, Chengshou Zhang, Xin Liu, Min Chen, Kaijun Wang
{"title":"Management of fracture and displacement of a previously successful bilateral transconjunctival ab-externo XEN gel stent: a case report.","authors":"Qi Zhang, Chengshou Zhang, Xin Liu, Min Chen, Kaijun Wang","doi":"10.1186/s12886-025-03922-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The XEN45 Gel Stent (XGS) is an innovative, minimally invasive glaucoma surgery device, which is typically inserted via an ab-interno method, avoiding conjunctival dissection. With increasing experience, some surgeons have advocated for a transconjunctival ab-externo approach, with or without conjunctival dissection, for the delivery of XGS.</p><p><strong>Case presentation: </strong>A 33-year-old male patient with a history of primary open-angle glaucoma diagnosed three years ago presented to the clinic with the complaint of visual field loss. This case report presents the initial implantation of XGS in both glaucoma eyes, using the transconjunctival ab-externo technique without conjunctival dissection. However, subsequent follow-up revealed that in the left eye, the XGS had been fractured as a result of external force. Meanwhile, in the right eye, the displacement of the XGS was attributed to the surgical needlework. To facilitate re-implantation, the transconjunctival ab-externo approach with conjunctival dissection was employed to enhance the securement of the XGS.</p><p><strong>Conclusions: </strong>The case highlights that external force and needling can cause XGS fracture and displacement. To reduce this risk, employing a transconjunctival ab-externo approach with conjunctival dissection and securing the XGS with sutures was found to decrease complications, indicating a more effective surgical strategy for XGS implantation.</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"25 1","pages":"98"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11869487/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-025-03922-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The XEN45 Gel Stent (XGS) is an innovative, minimally invasive glaucoma surgery device, which is typically inserted via an ab-interno method, avoiding conjunctival dissection. With increasing experience, some surgeons have advocated for a transconjunctival ab-externo approach, with or without conjunctival dissection, for the delivery of XGS.

Case presentation: A 33-year-old male patient with a history of primary open-angle glaucoma diagnosed three years ago presented to the clinic with the complaint of visual field loss. This case report presents the initial implantation of XGS in both glaucoma eyes, using the transconjunctival ab-externo technique without conjunctival dissection. However, subsequent follow-up revealed that in the left eye, the XGS had been fractured as a result of external force. Meanwhile, in the right eye, the displacement of the XGS was attributed to the surgical needlework. To facilitate re-implantation, the transconjunctival ab-externo approach with conjunctival dissection was employed to enhance the securement of the XGS.

Conclusions: The case highlights that external force and needling can cause XGS fracture and displacement. To reduce this risk, employing a transconjunctival ab-externo approach with conjunctival dissection and securing the XGS with sutures was found to decrease complications, indicating a more effective surgical strategy for XGS implantation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信