Removal of rhodamine 6G from aqueous solution in a continuous mode using nano-micro composite membranes

Chris Ademola Bode-Aluko , Omoniyi Pereao , Alechine E. Ameh , Emmanuel Omoniyi , Alexander Nechaev , Leslie Petrik
{"title":"Removal of rhodamine 6G from aqueous solution in a continuous mode using nano-micro composite membranes","authors":"Chris Ademola Bode-Aluko ,&nbsp;Omoniyi Pereao ,&nbsp;Alechine E. Ameh ,&nbsp;Emmanuel Omoniyi ,&nbsp;Alexander Nechaev ,&nbsp;Leslie Petrik","doi":"10.1016/j.nwnano.2025.100096","DOIUrl":null,"url":null,"abstract":"<div><div>This research presents the production of nanofibers, track-etched membrane, and nanofiber/track-etched composite membranes and their dye rejection studies. Polyamide 6 nanofibers (PA6-nfs) and polyacrylonitrile nanofibers (PAN-nfs) were fabricated using an electrospinning technique. Their respective composites with the metalized track-etched polyethylene terephthalate film (PET-TM), PET-TMPA6, and PET-TMPAN were also fabricated via electrospinning. The membranes were characterized using HRSEM, TEM, BET, and TGA techniques. The rejection experiments were studied with respect to the pH and the concentration of rhodamine 6G (RD), as well as the flow rate of the system. The pH is the most significant parameter in the filtration system at higher dye concentrations. At pH 10, the rejection percentages of 10 mg/L RD were 91.27% for PET-TMPAN and 70.66% for PET-TMPA6 at a flow rate of 1 mL/min. Also, PAN-nfs, PA6-nfs, and PET-TM gave 65.97%, 36.80%, and 24.53%, respectively. The composite membranes have higher rejection capabilities in comparison to their respective nanofibers. The performance of PET-TMPAN at a lower flow rate of 0.5 mL/min showed that the RD rejection by PET-TMPAN increased by ≈5 percent (91.27 to 96.01). At a lower concentration of 2 mg/L (to simulate higher dilution in river water) and pH (5.6), PET-TMPAN had a 99.59% RD rejection. All the membranes were regenerated and reused. The composite membrane PET-TMPAN has the capability to remove RD at both higher (96.01%) and lower concentrations (99.59%) of RD at lower flow rate, thereby making the system applicable and easy to use in river water purification.</div></div>","PeriodicalId":100942,"journal":{"name":"Nano Trends","volume":"9 ","pages":"Article 100096"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nano Trends","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266697812500025X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This research presents the production of nanofibers, track-etched membrane, and nanofiber/track-etched composite membranes and their dye rejection studies. Polyamide 6 nanofibers (PA6-nfs) and polyacrylonitrile nanofibers (PAN-nfs) were fabricated using an electrospinning technique. Their respective composites with the metalized track-etched polyethylene terephthalate film (PET-TM), PET-TMPA6, and PET-TMPAN were also fabricated via electrospinning. The membranes were characterized using HRSEM, TEM, BET, and TGA techniques. The rejection experiments were studied with respect to the pH and the concentration of rhodamine 6G (RD), as well as the flow rate of the system. The pH is the most significant parameter in the filtration system at higher dye concentrations. At pH 10, the rejection percentages of 10 mg/L RD were 91.27% for PET-TMPAN and 70.66% for PET-TMPA6 at a flow rate of 1 mL/min. Also, PAN-nfs, PA6-nfs, and PET-TM gave 65.97%, 36.80%, and 24.53%, respectively. The composite membranes have higher rejection capabilities in comparison to their respective nanofibers. The performance of PET-TMPAN at a lower flow rate of 0.5 mL/min showed that the RD rejection by PET-TMPAN increased by ≈5 percent (91.27 to 96.01). At a lower concentration of 2 mg/L (to simulate higher dilution in river water) and pH (5.6), PET-TMPAN had a 99.59% RD rejection. All the membranes were regenerated and reused. The composite membrane PET-TMPAN has the capability to remove RD at both higher (96.01%) and lower concentrations (99.59%) of RD at lower flow rate, thereby making the system applicable and easy to use in river water purification.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信