Exploring the Ocular Transmission Potential of Severe Acute Respiratory Syndrome Coronavirus 2 and the Assessment of Conjunctival Swab Test Results: A Concise Review.

IF 1.2 Q3 OPHTHALMOLOGY
Journal of Current Ophthalmology Pub Date : 2025-01-18 eCollection Date: 2024-04-01 DOI:10.4103/joco.joco_35_24
Arash Mirzaei, Ali Djalilian, Seyed Mahbod Baharnoori, Bahram Bohrani Sefidan, Mansoor Shahriari, Kasra Cheraqpour, Mahmood Ghassemi, Allison Kufta, Mohammad Soleimani
{"title":"Exploring the Ocular Transmission Potential of Severe Acute Respiratory Syndrome Coronavirus 2 and the Assessment of Conjunctival Swab Test Results: A Concise Review.","authors":"Arash Mirzaei, Ali Djalilian, Seyed Mahbod Baharnoori, Bahram Bohrani Sefidan, Mansoor Shahriari, Kasra Cheraqpour, Mahmood Ghassemi, Allison Kufta, Mohammad Soleimani","doi":"10.4103/joco.joco_35_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the possibility of coronavirus disease 2019 (COVID-19) transmission through the eyes, particularly through the ocular surface and conjunctival route, as well as the positivity of conjunctival swab test.</p><p><strong>Methods: </strong>A narrative review was conducted to assess the possibility of COVID-19 transmission and the role of conjunctival swabs in diagnosing COVID-19 patients. Several studies were analyzed to compare the positivity rates and sensitivities of conjunctival swabs versus nasopharyngeal swabs.</p><p><strong>Results: </strong>Despite the fact that respiratory droplets are the major route of severe acute respiratory syndrome coronavirus 2 transmission, the eyes can potentially serve as an active (via tears) or passive route (via the nasolacrimal duct) of infection. Besides, conjunctival swabs exhibited a low positive rate and sensitivity for detecting COVID-19 compared to nasopharyngeal swabs. While nasopharyngeal swabs typically showed positivity rates between 60% and 100%, conjunctival swabs ranged from showing no detectable evidence to a 57% positivity rate.</p><p><strong>Conclusions: </strong>Despite the low transmission rate through the eyes, thorough consideration is necessary as ocular transmission cannot be entirely ruled out. Further research and vigilance are warranted to better understand and mitigate potential ocular routes of COVID-19 transmission.</p>","PeriodicalId":15423,"journal":{"name":"Journal of Current Ophthalmology","volume":"36 2","pages":"122-128"},"PeriodicalIF":1.2000,"publicationDate":"2025-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856114/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Current Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joco.joco_35_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the possibility of coronavirus disease 2019 (COVID-19) transmission through the eyes, particularly through the ocular surface and conjunctival route, as well as the positivity of conjunctival swab test.

Methods: A narrative review was conducted to assess the possibility of COVID-19 transmission and the role of conjunctival swabs in diagnosing COVID-19 patients. Several studies were analyzed to compare the positivity rates and sensitivities of conjunctival swabs versus nasopharyngeal swabs.

Results: Despite the fact that respiratory droplets are the major route of severe acute respiratory syndrome coronavirus 2 transmission, the eyes can potentially serve as an active (via tears) or passive route (via the nasolacrimal duct) of infection. Besides, conjunctival swabs exhibited a low positive rate and sensitivity for detecting COVID-19 compared to nasopharyngeal swabs. While nasopharyngeal swabs typically showed positivity rates between 60% and 100%, conjunctival swabs ranged from showing no detectable evidence to a 57% positivity rate.

Conclusions: Despite the low transmission rate through the eyes, thorough consideration is necessary as ocular transmission cannot be entirely ruled out. Further research and vigilance are warranted to better understand and mitigate potential ocular routes of COVID-19 transmission.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
6.70%
发文量
45
审稿时长
8 weeks
期刊介绍: Peer Review under the responsibility of Iranian Society of Ophthalmology Journal of Current Ophthalmology, the official publication of the Iranian Society of Ophthalmology, is a peer-reviewed, open-access, scientific journal that welcomes high quality original articles related to vision science and all fields of ophthalmology. Journal of Current Ophthalmology is the continuum of Iranian Journal of Ophthalmology published since 1969.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信