Long-term results after sutureless intrascleral fixation of the Carlevale intraocular lens: Changes in scleral pocket thickness over time.

IF 3 3区 医学 Q1 OPHTHALMOLOGY
Markus Schranz, Ioanna Dimakopoulou, Marcus Lisy, Victor Danzinger, Daniel Schartmüller, Claudette Abela-Formanek
{"title":"Long-term results after sutureless intrascleral fixation of the Carlevale intraocular lens: Changes in scleral pocket thickness over time.","authors":"Markus Schranz, Ioanna Dimakopoulou, Marcus Lisy, Victor Danzinger, Daniel Schartmüller, Claudette Abela-Formanek","doi":"10.1111/aos.17468","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the long-term effects and dynamic changes in scleral thickness above the T-haptic after sutureless scleral-fixated intraocular lens (sSFIOL) implantation using the FIL-SFF Carlevale lens.</p><p><strong>Setting: </strong>Single-centre, single-surgeon, prospective clinical trial, Department of Ophthalmology, Medical University of Vienna, Austria.</p><p><strong>Methods: </strong>Thirty-six eyes of 36 consecutive patients met the inclusion criteria for this post hoc analysis. Visual acuity, tilt and decentration of the IOL, as well as complications, were evaluated alongside imaging of the scleral pockets during multiple time points using the anterior optical coherence tomography (AS-OCT) system Tomey CASIA 2 in the bleb mode. The OCT scan pattern, oriented parallel to the T-shaped haptic of the IOL, facilitated manual analysis of images to measure scleral pocket thickness on both the temporal and nasal haptics. To compensate for distortions and non-perpendicular image acquisition, distal T-haptic thickness was also measured to calculate the relative scleral pocket thickness. For statistical evaluation, a linear mixed model was used, where we corrected for multiple measurements.</p><p><strong>Results: </strong>The mean follow-up period was 28 ± 11 months. Measured scleral thickness above the T-haptic exhibited a significant decrease on both temporal and nasal sides, translating to an estimated annual decrease of approximately 0.03 mm (p < 0.001). Postoperatively, best-corrected visual acuity (BCVA) significantly improved from 0.77 ± 0.74 logMAR preoperatively to 0.41 ± 0.60 (p < 0.001). IOL tilt increased slightly from 7.23° ± 3.43° to 7.71° ± 3.70° (p = 0.003), while decentration significantly decreased from 0.41 ± 0.21 to 0.39 ± 0.20 mm (p < 0.001) postoperatively.</p><p><strong>Conclusions: </strong>Long-term evaluation of Carlevale sSFIOL implantation demonstrated a significant improvement in postoperative BCVA. However, we observed a thinning of the scleral pocket thickness, raising questions about its clinical significance and the viability of subconjunctival placement of T-haptics in the long term. Further studies are necessary to evaluate the long-term patency of the scleral pocket.</p>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/aos.17468","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the long-term effects and dynamic changes in scleral thickness above the T-haptic after sutureless scleral-fixated intraocular lens (sSFIOL) implantation using the FIL-SFF Carlevale lens.

Setting: Single-centre, single-surgeon, prospective clinical trial, Department of Ophthalmology, Medical University of Vienna, Austria.

Methods: Thirty-six eyes of 36 consecutive patients met the inclusion criteria for this post hoc analysis. Visual acuity, tilt and decentration of the IOL, as well as complications, were evaluated alongside imaging of the scleral pockets during multiple time points using the anterior optical coherence tomography (AS-OCT) system Tomey CASIA 2 in the bleb mode. The OCT scan pattern, oriented parallel to the T-shaped haptic of the IOL, facilitated manual analysis of images to measure scleral pocket thickness on both the temporal and nasal haptics. To compensate for distortions and non-perpendicular image acquisition, distal T-haptic thickness was also measured to calculate the relative scleral pocket thickness. For statistical evaluation, a linear mixed model was used, where we corrected for multiple measurements.

Results: The mean follow-up period was 28 ± 11 months. Measured scleral thickness above the T-haptic exhibited a significant decrease on both temporal and nasal sides, translating to an estimated annual decrease of approximately 0.03 mm (p < 0.001). Postoperatively, best-corrected visual acuity (BCVA) significantly improved from 0.77 ± 0.74 logMAR preoperatively to 0.41 ± 0.60 (p < 0.001). IOL tilt increased slightly from 7.23° ± 3.43° to 7.71° ± 3.70° (p = 0.003), while decentration significantly decreased from 0.41 ± 0.21 to 0.39 ± 0.20 mm (p < 0.001) postoperatively.

Conclusions: Long-term evaluation of Carlevale sSFIOL implantation demonstrated a significant improvement in postoperative BCVA. However, we observed a thinning of the scleral pocket thickness, raising questions about its clinical significance and the viability of subconjunctival placement of T-haptics in the long term. Further studies are necessary to evaluate the long-term patency of the scleral pocket.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Ophthalmologica
Acta Ophthalmologica 医学-眼科学
CiteScore
7.60
自引率
5.90%
发文量
433
审稿时长
6 months
期刊介绍: Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER). Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信