{"title":"Fast susceptibility-weighted imaging using echo planar imaging at 1.5 T for swallow tail sign biomarker detection in Parkinson's disease","authors":"M.R. Hamed ,&nbsp;M.A. Kenawy ,&nbsp;S. Mohamed ,&nbsp;M. El-Samahy ,&nbsp;K.T. Ereiba ,&nbsp;A. Eissa","doi":"10.1016/j.radi.2025.102903","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>This study evaluated the feasibility and diagnostic accuracy of a fast-imaging technique combining Echo Planar Imaging (EPI) and Susceptibility-Weighted Imaging (SWI) at 1.5 T for visualizing the Swallow Tail Sign (STS) in Parkinson's Disease (PD). The STS, a biomarker linked to PD pathogenesis, offers promise for non-invasive diagnosis. However, conventional SWI often requires high field strengths and lengthy scan times, limiting accessibility. This study aimed to provide a faster, more practical alternative for PD diagnosis.</div></div><div><h3>Methods</h3><div>A prospective study included 130 participants (22 early-stage PD, 108 healthy controls [HC]) recruited consecutively from a neurology clinic. Eligibility required freedom from MRI contraindications. A fast EPI-SWI sequence was employed as the primary diagnostic tool, with Movement Disorder Society criteria serving as the reference standard. Diagnostic measures, including sensitivity, specificity, predictive values, and the area under the ROC curve (AUC), were calculated.</div></div><div><h3>Results</h3><div>After excluding participants with motion artifacts or suboptimal image quality, 120 participants (20 PD, 100 HC) were included in the analysis. The fast EPI-SWI technique demonstrated 100 % sensitivity, 96 % specificity, a positive predictive value (PPV) of 83.3 %, and a negative predictive value (NPV) of 100 %. The AUC for diagnostic accuracy was 0.98.</div></div><div><h3>Conclusion</h3><div>The fast EPI-SWI sequence at 1.5 T achieved high diagnostic accuracy for detecting the STS, offering a practical solution for early PD diagnosis in settings with limited access to high-field MRI.</div></div><div><h3>Implications for practice</h3><div>The use of EPI SWI for detecting the Swallow Tail Sign could provide a faster and more accessible method for early diagnosis of Parkinson's disease in clinical settings, particularly in resource-limited environments.</div></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":"31 2","pages":"Article 102903"},"PeriodicalIF":2.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817425000446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

This study evaluated the feasibility and diagnostic accuracy of a fast-imaging technique combining Echo Planar Imaging (EPI) and Susceptibility-Weighted Imaging (SWI) at 1.5 T for visualizing the Swallow Tail Sign (STS) in Parkinson's Disease (PD). The STS, a biomarker linked to PD pathogenesis, offers promise for non-invasive diagnosis. However, conventional SWI often requires high field strengths and lengthy scan times, limiting accessibility. This study aimed to provide a faster, more practical alternative for PD diagnosis.

Methods

A prospective study included 130 participants (22 early-stage PD, 108 healthy controls [HC]) recruited consecutively from a neurology clinic. Eligibility required freedom from MRI contraindications. A fast EPI-SWI sequence was employed as the primary diagnostic tool, with Movement Disorder Society criteria serving as the reference standard. Diagnostic measures, including sensitivity, specificity, predictive values, and the area under the ROC curve (AUC), were calculated.

Results

After excluding participants with motion artifacts or suboptimal image quality, 120 participants (20 PD, 100 HC) were included in the analysis. The fast EPI-SWI technique demonstrated 100 % sensitivity, 96 % specificity, a positive predictive value (PPV) of 83.3 %, and a negative predictive value (NPV) of 100 %. The AUC for diagnostic accuracy was 0.98.

Conclusion

The fast EPI-SWI sequence at 1.5 T achieved high diagnostic accuracy for detecting the STS, offering a practical solution for early PD diagnosis in settings with limited access to high-field MRI.

Implications for practice

The use of EPI SWI for detecting the Swallow Tail Sign could provide a faster and more accessible method for early diagnosis of Parkinson's disease in clinical settings, particularly in resource-limited environments.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiography
Radiography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍: Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信