The effect of knee-flexion angle on peak force and muscle activation during isometric knee-flexor strength testing using the Nordbord device in soccer players.

Jonathan M Taylor, Hermes Pallotta, Phillip Smith, Will Short, Matthew D Wright, Paul Chesterton
{"title":"The effect of knee-flexion angle on peak force and muscle activation during isometric knee-flexor strength testing using the Nordbord device in soccer players.","authors":"Jonathan M Taylor, Hermes Pallotta, Phillip Smith, Will Short, Matthew D Wright, Paul Chesterton","doi":"10.1080/24733938.2025.2471316","DOIUrl":null,"url":null,"abstract":"<p><p>Isometric knee-flexor testing is commonplace in soccer, yet data to inform choice of knee-flexion angle are limited. This study aimed to compare peak force production and muscle activation between two isometric knee-flexor tests. To compare peak force, 43 male soccer players (age 21.5 ± 5 years; stature 180.3 ± 6.3 cm; body mass 74.6 ± 8.9 kg) completed 3 × 5-second maximal efforts on the Nordbord device (Vald Performance) with a 0- (ISO-Prone) and 30-degree (ISO-30) knee angle, respectively. To compare peak muscle activation, a further 13 trained male participants (25 ± 6 years; 178.2 ± 5.6 cm; 79.6 ± 13.2 kg) completed 3 × 5-second maximal efforts with wireless surface electromyography electrodes placed on the Gluteus Maximus, Adductor Magnus, Semitendinosus, Biceps Femoris (long and short heads) and Medial Gastrocnemius. Paired samples t-tests were used to detect differences in force output between tests and Pearson's correlations to quantify associations. A Yuen's modified t-test estimated the trimmed mean differences in muscle activation between tests. Higher peak forces were observed in the ISO-30, with mean differences of 56.4N (36.8 to 75.9 [95% CI]) and 52.9N (33.7 to 72.3 [95% CI]) for right (367 vs 314N) and left legs (351 vs 294N), respectively. Moderate correlations were observed in peak force for left (<i>r =</i> 0.55 (0.29 to 0.73 [95%CI])) and right (<i>r =</i> 0.64 (0.42 to 0.79 [95%CI]) legs. No differences in muscle activation were observed. Peak force varies between the ISO-Prone and ISO-30, with moderate associations between tests, indicating that the tests should not be used interchangeably.</p>","PeriodicalId":74767,"journal":{"name":"Science & medicine in football","volume":" ","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science & medicine in football","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/24733938.2025.2471316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Isometric knee-flexor testing is commonplace in soccer, yet data to inform choice of knee-flexion angle are limited. This study aimed to compare peak force production and muscle activation between two isometric knee-flexor tests. To compare peak force, 43 male soccer players (age 21.5 ± 5 years; stature 180.3 ± 6.3 cm; body mass 74.6 ± 8.9 kg) completed 3 × 5-second maximal efforts on the Nordbord device (Vald Performance) with a 0- (ISO-Prone) and 30-degree (ISO-30) knee angle, respectively. To compare peak muscle activation, a further 13 trained male participants (25 ± 6 years; 178.2 ± 5.6 cm; 79.6 ± 13.2 kg) completed 3 × 5-second maximal efforts with wireless surface electromyography electrodes placed on the Gluteus Maximus, Adductor Magnus, Semitendinosus, Biceps Femoris (long and short heads) and Medial Gastrocnemius. Paired samples t-tests were used to detect differences in force output between tests and Pearson's correlations to quantify associations. A Yuen's modified t-test estimated the trimmed mean differences in muscle activation between tests. Higher peak forces were observed in the ISO-30, with mean differences of 56.4N (36.8 to 75.9 [95% CI]) and 52.9N (33.7 to 72.3 [95% CI]) for right (367 vs 314N) and left legs (351 vs 294N), respectively. Moderate correlations were observed in peak force for left (r = 0.55 (0.29 to 0.73 [95%CI])) and right (r = 0.64 (0.42 to 0.79 [95%CI]) legs. No differences in muscle activation were observed. Peak force varies between the ISO-Prone and ISO-30, with moderate associations between tests, indicating that the tests should not be used interchangeably.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信