[Analysis of the difference in CT radiation dose between children's specialized hospitals and general hospitals].

Q3 Medicine
S L Yang, C X Liu, Y Ni, Y Liu, J M Zhang, Q Zeng
{"title":"[Analysis of the difference in CT radiation dose between children's specialized hospitals and general hospitals].","authors":"S L Yang, C X Liu, Y Ni, Y Liu, J M Zhang, Q Zeng","doi":"10.3760/cma.j.cn121094-20240109-00007","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To analyze the differences in pediatric CT radiation dose and scanning parameter Settings between children's specialized hospitals and general hospitals, and to provide reference for the optimization strategy of pediatric CT radiation dose. <b>Methods:</b> From July to August 2022, a stratified sampling method was used to select 7 comprehensive hospitals and 2 children's hospitals in Tianjin, and on-site survey was conducted to collect the dose data of children's head, chest, and abdomen and pelvic CT examinations in these hospitals. The Wilcoxon rank sum test was used to analyze the differences in CTDI(vol) and DLP of the same age group and examination site among different types of hospitals, and the stepwise regression analysis method was used to analyze the effects of age, examination site, and scanning parameters on radiation dose CTDI(vol) and DLP. <b>Results:</b> The CTDI(vol) and DLP of head (1-<5, 5-<10, 10-<15 years old group), chest (5-<10, 10-<15 years old group) and abdomen (1-<5, 5-<10, 10-<15 years old group) in children's specialized hospitals were lower than those in general hospitals (head, 1-<5, 5-<10, 10-<15 years old group, CTDI(vol): <i>Z</i>=-9.32, -6.17, -9.86, <i>P</i><0.001, DLP, <i>Z</i>=-4.41, -4.14, -5.76, <i>P</i><0.001; chest, 5-<10, 10-<15 years old group, CTDI(vol): <i>Z</i>=-3.84, -5.35, <i>P</i><0.001, DLP, <i>Z</i>=-3.59, -4.63, <i>P</i><0.001; abdomen, 1-<5、5-<10 and 10-<15 years old group, CTDI(vol): <i>Z</i>=-7.88, -7.78, -8.53, <i>P</i><0.001, DLP, <i>Z</i>=-7.24, -5.92, -3.44, <i>P</i><0.001). The CT radiation dose in children was positively correlated with age, tube voltage, tube current time product and scan length, and negatively correlated with pitch and hospital type (general hospital and children's hospital) . <b>Conclusion:</b> There are some differences in the CT radiation dose and scanning parameters between children's hospitals and general hospitals. The results indicate that there is still much room for improvement in the optimization of radiation dose in pediatric CT examination.</p>","PeriodicalId":23958,"journal":{"name":"中华劳动卫生职业病杂志","volume":"43 2","pages":"117-122"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华劳动卫生职业病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121094-20240109-00007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To analyze the differences in pediatric CT radiation dose and scanning parameter Settings between children's specialized hospitals and general hospitals, and to provide reference for the optimization strategy of pediatric CT radiation dose. Methods: From July to August 2022, a stratified sampling method was used to select 7 comprehensive hospitals and 2 children's hospitals in Tianjin, and on-site survey was conducted to collect the dose data of children's head, chest, and abdomen and pelvic CT examinations in these hospitals. The Wilcoxon rank sum test was used to analyze the differences in CTDI(vol) and DLP of the same age group and examination site among different types of hospitals, and the stepwise regression analysis method was used to analyze the effects of age, examination site, and scanning parameters on radiation dose CTDI(vol) and DLP. Results: The CTDI(vol) and DLP of head (1-<5, 5-<10, 10-<15 years old group), chest (5-<10, 10-<15 years old group) and abdomen (1-<5, 5-<10, 10-<15 years old group) in children's specialized hospitals were lower than those in general hospitals (head, 1-<5, 5-<10, 10-<15 years old group, CTDI(vol): Z=-9.32, -6.17, -9.86, P<0.001, DLP, Z=-4.41, -4.14, -5.76, P<0.001; chest, 5-<10, 10-<15 years old group, CTDI(vol): Z=-3.84, -5.35, P<0.001, DLP, Z=-3.59, -4.63, P<0.001; abdomen, 1-<5、5-<10 and 10-<15 years old group, CTDI(vol): Z=-7.88, -7.78, -8.53, P<0.001, DLP, Z=-7.24, -5.92, -3.44, P<0.001). The CT radiation dose in children was positively correlated with age, tube voltage, tube current time product and scan length, and negatively correlated with pitch and hospital type (general hospital and children's hospital) . Conclusion: There are some differences in the CT radiation dose and scanning parameters between children's hospitals and general hospitals. The results indicate that there is still much room for improvement in the optimization of radiation dose in pediatric CT examination.

求助全文
约1分钟内获得全文 求助全文
来源期刊
中华劳动卫生职业病杂志
中华劳动卫生职业病杂志 Medicine-Medicine (all)
CiteScore
1.00
自引率
0.00%
发文量
9764
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信