Study on an Injectable Chitosan-Lignin/Poloxamer Hydrogel Loaded with Platelet-Rich Plasma for Intrauterine Adhesion Treatment.

IF 4.7 3区 工程技术 Q1 POLYMER SCIENCE
Polymers Pub Date : 2025-02-11 DOI:10.3390/polym17040474
Zhipeng Yu, Yang Min, Qi Ouyang, Yuting Fu, Ying Mao, Shuanglin Xiang, Xiang Hu, Liuyun Jiang
{"title":"Study on an Injectable Chitosan-Lignin/Poloxamer Hydrogel Loaded with Platelet-Rich Plasma for Intrauterine Adhesion Treatment.","authors":"Zhipeng Yu, Yang Min, Qi Ouyang, Yuting Fu, Ying Mao, Shuanglin Xiang, Xiang Hu, Liuyun Jiang","doi":"10.3390/polym17040474","DOIUrl":null,"url":null,"abstract":"<p><p>It is a great challenge to obtain an ideal hydrogel for the clinical treatment of intrauterine adhesion (IUA) disease. Here, a novel injectable chitosan-lignin/poloxamer hydrogel loaded with platelet-rich plasma (CL-PF127@PRP) was prepared by self-assembly at room temperature. Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), rheological analysis, and injectable writing were used to characterize the structure of the hydrogel. The results confirmed that the amino group of chitosan and the sulfonic group of sodium lignosulfonate were ionic-crosslinked by electrostatic attraction, which stabilized the three-dimensional structure of the PF127 hydrogel loaded with PRP, and PRP made the porous structure gradually become tight. Moreover, the CL-PF127@PRP hydrogel displayed good injectability and a solid state. The soaking experiment showed that the CL-PF127@PRP hydrogel had suitable degradation at pH = 7 and a good PRP release rate (PRP release 70% at 96 h). Cell experiments in vitro demonstrated that the CL-PF127@PRP hydrogel possessed good biocompatibility, an anti-inflammatory function, and pro-angiogenic activity. Furthermore, an animal experiment of skin wound and IUA confirmed that the skin wound closure rate of the CL-PF127@PRP hydrogel was over 50% on the seventh day. PRP improved the thickness of the endometrium and uterus receptivity, suggesting that the CL-PF127@PRP hydrogel offers great promise for the clinical treatment of IUA.</p>","PeriodicalId":20416,"journal":{"name":"Polymers","volume":"17 4","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11858913/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymers","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/polym17040474","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0

Abstract

It is a great challenge to obtain an ideal hydrogel for the clinical treatment of intrauterine adhesion (IUA) disease. Here, a novel injectable chitosan-lignin/poloxamer hydrogel loaded with platelet-rich plasma (CL-PF127@PRP) was prepared by self-assembly at room temperature. Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), rheological analysis, and injectable writing were used to characterize the structure of the hydrogel. The results confirmed that the amino group of chitosan and the sulfonic group of sodium lignosulfonate were ionic-crosslinked by electrostatic attraction, which stabilized the three-dimensional structure of the PF127 hydrogel loaded with PRP, and PRP made the porous structure gradually become tight. Moreover, the CL-PF127@PRP hydrogel displayed good injectability and a solid state. The soaking experiment showed that the CL-PF127@PRP hydrogel had suitable degradation at pH = 7 and a good PRP release rate (PRP release 70% at 96 h). Cell experiments in vitro demonstrated that the CL-PF127@PRP hydrogel possessed good biocompatibility, an anti-inflammatory function, and pro-angiogenic activity. Furthermore, an animal experiment of skin wound and IUA confirmed that the skin wound closure rate of the CL-PF127@PRP hydrogel was over 50% on the seventh day. PRP improved the thickness of the endometrium and uterus receptivity, suggesting that the CL-PF127@PRP hydrogel offers great promise for the clinical treatment of IUA.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Polymers
Polymers POLYMER SCIENCE-
CiteScore
8.00
自引率
16.00%
发文量
4697
审稿时长
1.3 months
期刊介绍: Polymers (ISSN 2073-4360) is an international, open access journal of polymer science. It publishes research papers, short communications and review papers. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Polymers provides an interdisciplinary forum for publishing papers which advance the fields of (i) polymerization methods, (ii) theory, simulation, and modeling, (iii) understanding of new physical phenomena, (iv) advances in characterization techniques, and (v) harnessing of self-assembly and biological strategies for producing complex multifunctional structures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信