Optimization of Albuterol Delivery via Anesthesia Bag in Pediatric Critical Care.

IF 4.9 3区 医学 Q1 PHARMACOLOGY & PHARMACY
Sébastien Tessier, Victoria K Ploszay, Christian Robitaille, Jigneshkumar Vaghasiya, Andrew J Halayko, Louise Chartrand
{"title":"Optimization of Albuterol Delivery via Anesthesia Bag in Pediatric Critical Care.","authors":"Sébastien Tessier, Victoria K Ploszay, Christian Robitaille, Jigneshkumar Vaghasiya, Andrew J Halayko, Louise Chartrand","doi":"10.3390/pharmaceutics17020218","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> Aerosolized medications are common practice for mechanically ventilated pediatric patients. Infants often receive nebulized medications via hand ventilation using an anesthesia bag, but evidence on optimal aerosol delivery with this method is limited. For this study, various configurations of the Mapleson breathing circuit were tested to optimize albuterol delivery to a simulated pediatric model. <b>Methods:</b> Using a simulated pediatric lung model (ASL 5000) with the semi-open Mapleson anesthesia circuit, 2.5 mg/3 mL of albuterol sulfate solution was nebulized to a viral/bacterial filter (Respiguard 202). Four models were compared with varying fresh gas flows (FGFs), small-volume nebulizer (SVN) placements, and adjusting dead space. Five Registered Respiratory Therapists (RRTs) bagged the aerosol into a collection filter following defined ventilation parameters. Each model was tested in random order to avoid fatigue bias. Albuterol concentrations eluted from in-line filters were measured by spectrophotometry (absorbance at 276 nm). <b>Results:</b> No inter-user variability was observed among the RRTs. Significant differences in albuterol recovered were noted between models (One Way ANOVA, Tukey's post hoc, n = 5). Model 4, with the nebulizer closest to the collecting filter, recovered 21.77 ± 1.89% of albuterol. The standard clinical model was the least effective, with only 0.10 ± 0.17% albuterol recovery. <b>Conclusions:</b> Modifying the anesthesia breathing circuit significantly improved aerosol drug delivery efficiency. Our findings suggest that current clinical practices for nebulized drug delivery are inefficient and can be markedly improved with simple adjustments in nebulizer positioning and gas flow within the circuit.</p>","PeriodicalId":19894,"journal":{"name":"Pharmaceutics","volume":"17 2","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/pharmaceutics17020218","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: Aerosolized medications are common practice for mechanically ventilated pediatric patients. Infants often receive nebulized medications via hand ventilation using an anesthesia bag, but evidence on optimal aerosol delivery with this method is limited. For this study, various configurations of the Mapleson breathing circuit were tested to optimize albuterol delivery to a simulated pediatric model. Methods: Using a simulated pediatric lung model (ASL 5000) with the semi-open Mapleson anesthesia circuit, 2.5 mg/3 mL of albuterol sulfate solution was nebulized to a viral/bacterial filter (Respiguard 202). Four models were compared with varying fresh gas flows (FGFs), small-volume nebulizer (SVN) placements, and adjusting dead space. Five Registered Respiratory Therapists (RRTs) bagged the aerosol into a collection filter following defined ventilation parameters. Each model was tested in random order to avoid fatigue bias. Albuterol concentrations eluted from in-line filters were measured by spectrophotometry (absorbance at 276 nm). Results: No inter-user variability was observed among the RRTs. Significant differences in albuterol recovered were noted between models (One Way ANOVA, Tukey's post hoc, n = 5). Model 4, with the nebulizer closest to the collecting filter, recovered 21.77 ± 1.89% of albuterol. The standard clinical model was the least effective, with only 0.10 ± 0.17% albuterol recovery. Conclusions: Modifying the anesthesia breathing circuit significantly improved aerosol drug delivery efficiency. Our findings suggest that current clinical practices for nebulized drug delivery are inefficient and can be markedly improved with simple adjustments in nebulizer positioning and gas flow within the circuit.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Pharmaceutics
Pharmaceutics Pharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
7.90
自引率
11.10%
发文量
2379
审稿时长
16.41 days
期刊介绍: Pharmaceutics (ISSN 1999-4923) is an open access journal which provides an advanced forum for the science and technology of pharmaceutics and biopharmaceutics. It publishes reviews, regular research papers, communications,  and short notes. Covered topics include pharmacokinetics, toxicokinetics, pharmacodynamics, pharmacogenetics and pharmacogenomics, and pharmaceutical formulation. Our aim is to encourage scientists to publish their experimental and theoretical details in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信