Diagnostic accuracy of ECG smart chest patches versus PPG smartwatches for atrial fibrillation detection: a systematic review and meta-analysis.

IF 2 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Olivier Sibomana, Clyde Moono Hakayuwa, Abraham Obianke, Hubert Gahire, Jildas Munyantore, Matimba Molly Chilala
{"title":"Diagnostic accuracy of ECG smart chest patches versus PPG smartwatches for atrial fibrillation detection: a systematic review and meta-analysis.","authors":"Olivier Sibomana, Clyde Moono Hakayuwa, Abraham Obianke, Hubert Gahire, Jildas Munyantore, Matimba Molly Chilala","doi":"10.1186/s12872-025-04582-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Atrial fibrillation (AF), the most common form of cardiac arrhythmia, is associated with significant morbidity, mortality, and financial burden. Traditional diagnostic methods, such as 12-lead electrocardiograms (ECG), have limitations in detecting intermittent AF episodes. Consequently, smart wearables have been introduced to enhance continuous AF monitoring. This systematic review and meta-analysis aimed to evaluate and compare the diagnostic accuracy of ECG smart chest patches and photoplethysmography (PPG)- based smartwatches in AF detection.</p><p><strong>Methods: </strong>From august 16-20, 2024, a comprehensive search was conducted across PubMed/MEDLINE, DOAJ, AJOL, and the Cochrane Library. Original studies assessing the performance of ECG smart chest patches and PPG smartwatches in detecting AF were included. Studies were screened based on predefined inclusion and exclusion criteria, and the most relevant were finally included. For ECG smart chest patches and PPG smartwatches groups, random-effects model was used to pool these performance metrics. Statistical analyses were performed using Jamovi 2.3.28, with a significance threshold of p < 0.05.</p><p><strong>Results: </strong>A total of 15 studies were included in the current systematic review and meta-analysis. ECG smart chest patches demonstrated a pooled sensitivity of 96.1% [(95% CI: 91.3-100.8), (I² = 94.59%)], and a pooled specificity of 97.5% [(95% CI: 94.7-100.2), (I² = 79.1%)]. PPG smartwatches showed a pooled sensitivity of 97.4% [(95% CI: 96.5-98.3), (I² = 3.16%)], and a pooled specificity of 96.6% [(95% CI: 94.9-98.3), (I² = 75.94%)]. Comparatively, both ECG smart chest patches and PPG smartwatches exhibited excellent performance in atrial fibrillation detection, with PPG smartwatches showing slightly higher sensitivity and ECG chest patches exhibiting marginally greater specificity.</p><p><strong>Conclusion: </strong>Both ECG smart chest patches and PPG smartwatches are highly effective for detecting atrial fibrillation. However, further advancements are needed to match their accuracy with that of standard diagnostic methods and achieve comprehensive digital cardiac monitoring.</p>","PeriodicalId":9195,"journal":{"name":"BMC Cardiovascular Disorders","volume":"25 1","pages":"132"},"PeriodicalIF":2.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Cardiovascular Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12872-025-04582-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Atrial fibrillation (AF), the most common form of cardiac arrhythmia, is associated with significant morbidity, mortality, and financial burden. Traditional diagnostic methods, such as 12-lead electrocardiograms (ECG), have limitations in detecting intermittent AF episodes. Consequently, smart wearables have been introduced to enhance continuous AF monitoring. This systematic review and meta-analysis aimed to evaluate and compare the diagnostic accuracy of ECG smart chest patches and photoplethysmography (PPG)- based smartwatches in AF detection.

Methods: From august 16-20, 2024, a comprehensive search was conducted across PubMed/MEDLINE, DOAJ, AJOL, and the Cochrane Library. Original studies assessing the performance of ECG smart chest patches and PPG smartwatches in detecting AF were included. Studies were screened based on predefined inclusion and exclusion criteria, and the most relevant were finally included. For ECG smart chest patches and PPG smartwatches groups, random-effects model was used to pool these performance metrics. Statistical analyses were performed using Jamovi 2.3.28, with a significance threshold of p < 0.05.

Results: A total of 15 studies were included in the current systematic review and meta-analysis. ECG smart chest patches demonstrated a pooled sensitivity of 96.1% [(95% CI: 91.3-100.8), (I² = 94.59%)], and a pooled specificity of 97.5% [(95% CI: 94.7-100.2), (I² = 79.1%)]. PPG smartwatches showed a pooled sensitivity of 97.4% [(95% CI: 96.5-98.3), (I² = 3.16%)], and a pooled specificity of 96.6% [(95% CI: 94.9-98.3), (I² = 75.94%)]. Comparatively, both ECG smart chest patches and PPG smartwatches exhibited excellent performance in atrial fibrillation detection, with PPG smartwatches showing slightly higher sensitivity and ECG chest patches exhibiting marginally greater specificity.

Conclusion: Both ECG smart chest patches and PPG smartwatches are highly effective for detecting atrial fibrillation. However, further advancements are needed to match their accuracy with that of standard diagnostic methods and achieve comprehensive digital cardiac monitoring.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Cardiovascular Disorders
BMC Cardiovascular Disorders CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.50
自引率
0.00%
发文量
480
审稿时长
1 months
期刊介绍: BMC Cardiovascular Disorders is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the heart and circulatory system, as well as related molecular and cell biology, genetics, pathophysiology, epidemiology, and controlled trials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信