{"title":"Clinical application of the quantitative fetal heart quantification in the evaluation of right heart function in fetuses with redundancy foramen ovale flap.","authors":"Xiao-Rong Su, Ai-Lin Wang, Hong-Xia Tie, Qiong-Yu Yang, Shu-Na Cao, Tian-Gang Li","doi":"10.1186/s12880-025-01601-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate the clinical value of fetal heart quantification (fetal HQ) in the evaluation of right ventricular size, morphology and cardiac function in fetuses with redundancy foramen ovale flap (RFOF).</p><p><strong>Methods: </strong>31 fetuses diagnosed with RFOF through echocardiography from September 2021 to December 2023 were selected as the control group, and 62 healthy fetuses that matched the age and gestational period of the pregnant women in the RFOF group were chosen as the control group. Fetal HQ software provided by GE Voluson E10 was employed to automatically track endocardial parameters of the right ventricle in 24 segments.</p><p><strong>Results: </strong>The internal diameter of foramen ovale in RFOF group was significantly smaller than that of normal fetal diameter in control group, with statistical significance (P < 0.05). Comparing the morphological parameters of the fetuses in the RFOF group and the control group, there was no statistically significant difference in the GSI scores (P > 0.05), but the RV-LED of the fetuses in the RFOF group in the segments of 1-24 were higher than the fetuses in the normal control group (both P < 0.05), and the RV-SI was lower than that in the normal control group (all P < 0.05).</p><p><strong>Conclusions: </strong>The Fetal HQ technique enables accurate localisation of the site of the RFOF foetal lesion by rapid quantitative analysis of morphological and functional parameters of the right ventricle of the foetal heart.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"62"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11863686/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-025-01601-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To investigate the clinical value of fetal heart quantification (fetal HQ) in the evaluation of right ventricular size, morphology and cardiac function in fetuses with redundancy foramen ovale flap (RFOF).

Methods: 31 fetuses diagnosed with RFOF through echocardiography from September 2021 to December 2023 were selected as the control group, and 62 healthy fetuses that matched the age and gestational period of the pregnant women in the RFOF group were chosen as the control group. Fetal HQ software provided by GE Voluson E10 was employed to automatically track endocardial parameters of the right ventricle in 24 segments.

Results: The internal diameter of foramen ovale in RFOF group was significantly smaller than that of normal fetal diameter in control group, with statistical significance (P < 0.05). Comparing the morphological parameters of the fetuses in the RFOF group and the control group, there was no statistically significant difference in the GSI scores (P > 0.05), but the RV-LED of the fetuses in the RFOF group in the segments of 1-24 were higher than the fetuses in the normal control group (both P < 0.05), and the RV-SI was lower than that in the normal control group (all P < 0.05).

Conclusions: The Fetal HQ technique enables accurate localisation of the site of the RFOF foetal lesion by rapid quantitative analysis of morphological and functional parameters of the right ventricle of the foetal heart.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信