Enhancing the Sensitivity and Detection Depth of a Single-Sided Magnetic Particle Spectrometer Using Ferrite Cores

IF 2.1 3区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Qibin Wang;Kaixiong Yang;Lingwen Hou;Haohao Yan;Yu Zeng;Yihan Wang;Franziska Schrank;Harald Radermacher;Volkmar Schulz;Shouping Zhu
{"title":"Enhancing the Sensitivity and Detection Depth of a Single-Sided Magnetic Particle Spectrometer Using Ferrite Cores","authors":"Qibin Wang;Kaixiong Yang;Lingwen Hou;Haohao Yan;Yu Zeng;Yihan Wang;Franziska Schrank;Harald Radermacher;Volkmar Schulz;Shouping Zhu","doi":"10.1109/TMAG.2025.3535758","DOIUrl":null,"url":null,"abstract":"Magnetic particle spectroscopy (MPS), first developed in relation to magnetic particle imaging (MPI) since its introduction in 2005, has been widely applied in biomedical detection and the evaluation of magnetic nanoparticle (MNP) performance in MPI. Its high sensitivity, low cost, and portability make MPS an essential tool for these applications. However, traditional MPS devices are limited by their enclosed measurement chambers, which restrict their application to solutions placed in small test tubes. Therefore, developing MPS devices that are not constrained by the size of the subject is crucial for clinical applications. Single-sided MPS devices, which concentrate the coils on one side, are not restricted by the size of the object being measured, making them directly applicable to clinical research. However, single-sided MPS devices are currently limited in terms of detection depth and sensitivity due to the rapid attenuation of the magnetic field with distance. To address this issue, in this work, we propose incorporating a soft magnetic core (Mn-Zn ferrite) into the single-sided MPS to enhance the magnetic flux density of the excitation field, thereby increasing detection depth. Additionally, we introduce a surface receiving coil design to replace the traditional solenoidal receiving coil, further improving sensitivity. The results demonstrate that the sensitivity increases by approximately ten times, and the detection depth is doubled.","PeriodicalId":13405,"journal":{"name":"IEEE Transactions on Magnetics","volume":"61 3","pages":"1-8"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Magnetics","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10856215/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Magnetic particle spectroscopy (MPS), first developed in relation to magnetic particle imaging (MPI) since its introduction in 2005, has been widely applied in biomedical detection and the evaluation of magnetic nanoparticle (MNP) performance in MPI. Its high sensitivity, low cost, and portability make MPS an essential tool for these applications. However, traditional MPS devices are limited by their enclosed measurement chambers, which restrict their application to solutions placed in small test tubes. Therefore, developing MPS devices that are not constrained by the size of the subject is crucial for clinical applications. Single-sided MPS devices, which concentrate the coils on one side, are not restricted by the size of the object being measured, making them directly applicable to clinical research. However, single-sided MPS devices are currently limited in terms of detection depth and sensitivity due to the rapid attenuation of the magnetic field with distance. To address this issue, in this work, we propose incorporating a soft magnetic core (Mn-Zn ferrite) into the single-sided MPS to enhance the magnetic flux density of the excitation field, thereby increasing detection depth. Additionally, we introduce a surface receiving coil design to replace the traditional solenoidal receiving coil, further improving sensitivity. The results demonstrate that the sensitivity increases by approximately ten times, and the detection depth is doubled.
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Magnetics
IEEE Transactions on Magnetics 工程技术-工程:电子与电气
CiteScore
4.00
自引率
14.30%
发文量
565
审稿时长
4.1 months
期刊介绍: Science and technology related to the basic physics and engineering of magnetism, magnetic materials, applied magnetics, magnetic devices, and magnetic data storage. The IEEE Transactions on Magnetics publishes scholarly articles of archival value as well as tutorial expositions and critical reviews of classical subjects and topics of current interest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信