Validity and Inter-Device Reliability of the OTBeat BurnTM Monitor to Estimate Heart Rate During Exercise.

IF 2.2 Q2 SPORT SCIENCES
Sports Pub Date : 2025-02-08 DOI:10.3390/sports13020049
Matteo F de Leon, Clayton L Camic, Matthew J Herring, Christopher M Hill
{"title":"Validity and Inter-Device Reliability of the OTBeat Burn<sup>TM</sup> Monitor to Estimate Heart Rate During Exercise.","authors":"Matteo F de Leon, Clayton L Camic, Matthew J Herring, Christopher M Hill","doi":"10.3390/sports13020049","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to determine the accuracy and inter-device reliability of the OTBeat Burn<sup>TM</sup> heart rate monitor during an incremental test to exhaustion on a cycle ergometer. Twenty males (mean ± SD age = 21.1 ± 1.9 years) volunteered to complete a test to exhaustion on a cycle ergometer with OTBeat Burn<sup>TM</sup> devices placed on the forearm and upper arm, with a 12-lead electrocardiogram used as the criterion. The heart rate was recorded every 30 s and averaged across each two-minute stage. Accuracy was assessed through calculation of the mean absolute percent error (MAPE), Bland-Altman plot, and Lin's concordance correlation coefficient (CCC). An intraclass correlation coefficient (ICC) was used to assess the inter-device reliability. Statistical significance was set at α < 0.05. The MAPE (±SD), Bland-Altman regression analyses, and Lin's CCC values were 0.9 (±0.6)% and 0.8 (±0.5)%, r = 0.107 and 0.303, and r<i><sub>c</sub></i> = 0.998 and 0.998 for the forearm and the upper arm monitors, respectively. The ICC for inter-device reliability was <i>R</i> = 0.999. Our findings indicated the OTBeat Burn<sup>TM</sup> monitors placed on the forearm and upper arm provided highly accurate and reliable values when compared to an electrocardiogram from low to maximal exercise intensities.</p>","PeriodicalId":53303,"journal":{"name":"Sports","volume":"13 2","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11860634/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/sports13020049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was to determine the accuracy and inter-device reliability of the OTBeat BurnTM heart rate monitor during an incremental test to exhaustion on a cycle ergometer. Twenty males (mean ± SD age = 21.1 ± 1.9 years) volunteered to complete a test to exhaustion on a cycle ergometer with OTBeat BurnTM devices placed on the forearm and upper arm, with a 12-lead electrocardiogram used as the criterion. The heart rate was recorded every 30 s and averaged across each two-minute stage. Accuracy was assessed through calculation of the mean absolute percent error (MAPE), Bland-Altman plot, and Lin's concordance correlation coefficient (CCC). An intraclass correlation coefficient (ICC) was used to assess the inter-device reliability. Statistical significance was set at α < 0.05. The MAPE (±SD), Bland-Altman regression analyses, and Lin's CCC values were 0.9 (±0.6)% and 0.8 (±0.5)%, r = 0.107 and 0.303, and rc = 0.998 and 0.998 for the forearm and the upper arm monitors, respectively. The ICC for inter-device reliability was R = 0.999. Our findings indicated the OTBeat BurnTM monitors placed on the forearm and upper arm provided highly accurate and reliable values when compared to an electrocardiogram from low to maximal exercise intensities.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Sports
Sports SPORT SCIENCES-
CiteScore
4.10
自引率
7.40%
发文量
167
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信