The Reconstructed Individual Patient Data from Kaplan-Meier (IPDfromKM) Method for Non-Inferiority Analyses: A New Potential Application.

IF 2.3 Q3 BIOCHEMICAL RESEARCH METHODS
Eugenia Piragine, Sabrina Trippoli, Sara Veneziano, Andrea Messori, Vincenzo Calderone
{"title":"The Reconstructed Individual Patient Data from Kaplan-Meier (IPDfromKM) Method for Non-Inferiority Analyses: A New Potential Application.","authors":"Eugenia Piragine, Sabrina Trippoli, Sara Veneziano, Andrea Messori, Vincenzo Calderone","doi":"10.3390/mps8010013","DOIUrl":null,"url":null,"abstract":"<p><p>The IPDfromKM method, or Shiny method, is an artificial intelligence tool that enables indirect comparisons between studies by reconstructing individual patient data (IPD) from Kaplan-Meier (KM) curves. The IPDfromKM method is generally used for superiority analyses, but a further application could be represented by non-inferiority analyses. However, there are no studies supporting this methodological hypothesis. The aim of this work was to validate the IPDfromKM method for non-inferiority analyses by \"exploiting\" the well-described non-inferiority of implantable devices occluding the left atrial appendage compared to oral anticoagulants in patients with atrial fibrillation. We performed a systematic review searching for randomized controlled trials (RCTs) in the PubMed database and found five studies. The R software (version 4.3.3) was used to perform a standard survival analysis comparing Watchman and Amlet devices with warfarin. The hazard ratio (HR), with 95% confidence interval (CI), was the main parameter of our analysis. The results confirmed the non-inferiority of Amlet and Watchman compared to warfarin (HR of Watchman vs. warfarin: 1.23, 95% CI 0.80 to 1.9; HR of Amlet vs. warfarin: 1.05, 95% CI 0.61 to 1.80). Therefore, we proposed a new application of the IPDfromKM method that could be potentially relevant in decision-making for the management of this common cardiac arrhythmia and a wide range of other pathological conditions.</p>","PeriodicalId":18715,"journal":{"name":"Methods and Protocols","volume":"8 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11857869/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/mps8010013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The IPDfromKM method, or Shiny method, is an artificial intelligence tool that enables indirect comparisons between studies by reconstructing individual patient data (IPD) from Kaplan-Meier (KM) curves. The IPDfromKM method is generally used for superiority analyses, but a further application could be represented by non-inferiority analyses. However, there are no studies supporting this methodological hypothesis. The aim of this work was to validate the IPDfromKM method for non-inferiority analyses by "exploiting" the well-described non-inferiority of implantable devices occluding the left atrial appendage compared to oral anticoagulants in patients with atrial fibrillation. We performed a systematic review searching for randomized controlled trials (RCTs) in the PubMed database and found five studies. The R software (version 4.3.3) was used to perform a standard survival analysis comparing Watchman and Amlet devices with warfarin. The hazard ratio (HR), with 95% confidence interval (CI), was the main parameter of our analysis. The results confirmed the non-inferiority of Amlet and Watchman compared to warfarin (HR of Watchman vs. warfarin: 1.23, 95% CI 0.80 to 1.9; HR of Amlet vs. warfarin: 1.05, 95% CI 0.61 to 1.80). Therefore, we proposed a new application of the IPDfromKM method that could be potentially relevant in decision-making for the management of this common cardiac arrhythmia and a wide range of other pathological conditions.

基于Kaplan-Meier (IPDfromKM)方法的非劣效性分析:一种新的潜在应用。
IPDfromKM方法,或Shiny方法,是一种人工智能工具,通过从Kaplan-Meier (KM)曲线重建个体患者数据(IPD),实现研究之间的间接比较。IPDfromKM方法通常用于优势分析,但进一步的应用可以通过非劣效分析来表示。然而,没有研究支持这种方法论假设。这项工作的目的是验证IPDfromKM方法的非劣效性分析,通过“利用”在房颤患者中,与口服抗凝剂相比,阻塞左心房附件的植入式装置具有良好的非劣效性。我们对PubMed数据库中的随机对照试验(rct)进行了系统回顾,发现了5项研究。使用R软件(版本4.3.3)对Watchman和Amlet装置与华法林进行标准生存分析。风险比(HR), 95%置信区间(CI)是我们分析的主要参数。结果证实Amlet和Watchman与华法林相比无劣效性(Watchman vs.华法林HR: 1.23, 95% CI 0.80 ~ 1.9;Amlet与华法林的HR: 1.05, 95% CI 0.61 ~ 1.80)。因此,我们提出了一种新的IPDfromKM方法的应用,这可能与这种常见心律失常和广泛的其他病理状况的管理决策有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Methods and Protocols
Methods and Protocols Biochemistry, Genetics and Molecular Biology-Biochemistry, Genetics and Molecular Biology (miscellaneous)
CiteScore
3.60
自引率
0.00%
发文量
85
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信