{"title":"The Design and Feasibility of Optimal Treatment for Coronary Drug-Eluting Stent In-Stent Restenosis (OPEN-ISR)-A Prospective, Randomised, Multicentre Clinical Trial.","authors":"Péter Márton Kulyassa, Balázs Tamás Németh, István Hizoh, Laura Krisztina Jankó, Zoltán Ruzsa, Zoltán Jambrik, Brúnó Bánk Balázs, Dávid Becker, Béla Merkely, István Ferenc Édes","doi":"10.3390/jpm15020060","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is a cornerstone of the management of ischemic heart disease. However, in-stent restenosis (ISR) remains a significant clinical challenge, occurring in approximately 5-10% of patients undergoing PCI. This study is designed to compare the efficacy and safety of the primary therapeutic approaches for DES-ISR, specifically drug-coated balloons (DCBs)-paclitaxel-coated balloons (PCBs) and sirolimus-coated balloons (SCBs)-with a new-generation everolimus-eluting stent (EES), contributing to the evolving field of personalized medicine. <b>Methods and Analysis:</b> This prospective, multicentre, randomised, non-inferiority trial aims to enroll 150 patients with DES-ISR, who will be randomised into one of the following: SCB, PCB, or EES. The primary endpoint comparing DCB and EES is late lumen loss (LLL) at 6 months, as measured by quantitative coronary angiography (QCA). Secondary endpoints comparing the three arms include a device-oriented composite endpoint, intraluminal gain, optical coherence tomography (OCT) measured LLL, and correlations between LLL and quantitative flow ratio (QFR). The primary endpoint will be analysed using a non-inferiority design, with a margin set at 0.25 mm, for which the sample size was calculated. Statistical analysis of the primary endpoint will be conducted on an intention-to-treat basis with a one-tailed Mann-Whitney U test with a significance level of 95. Secondary endpoints will be analysed via superiority testing using ANOVA, the Kruskal-Wallis test, logistic regression, or Fisher's exact test, as appropriate. <b>Ethics and Dissemination:</b> The study protocol has been approved by the Medical Devices Department of the Hungarian National Institute of Pharmacy and Nutrition, ensuring compliance with ethical standards as outlined in the Declaration of Helsinki. All investigators declare no conflicts of interest related to this study. The trial is registered in ClinicalTrials.gov under the ID: NCT04862052.</p>","PeriodicalId":16722,"journal":{"name":"Journal of Personalized Medicine","volume":"15 2","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856948/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Personalized Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jpm15020060","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is a cornerstone of the management of ischemic heart disease. However, in-stent restenosis (ISR) remains a significant clinical challenge, occurring in approximately 5-10% of patients undergoing PCI. This study is designed to compare the efficacy and safety of the primary therapeutic approaches for DES-ISR, specifically drug-coated balloons (DCBs)-paclitaxel-coated balloons (PCBs) and sirolimus-coated balloons (SCBs)-with a new-generation everolimus-eluting stent (EES), contributing to the evolving field of personalized medicine. Methods and Analysis: This prospective, multicentre, randomised, non-inferiority trial aims to enroll 150 patients with DES-ISR, who will be randomised into one of the following: SCB, PCB, or EES. The primary endpoint comparing DCB and EES is late lumen loss (LLL) at 6 months, as measured by quantitative coronary angiography (QCA). Secondary endpoints comparing the three arms include a device-oriented composite endpoint, intraluminal gain, optical coherence tomography (OCT) measured LLL, and correlations between LLL and quantitative flow ratio (QFR). The primary endpoint will be analysed using a non-inferiority design, with a margin set at 0.25 mm, for which the sample size was calculated. Statistical analysis of the primary endpoint will be conducted on an intention-to-treat basis with a one-tailed Mann-Whitney U test with a significance level of 95. Secondary endpoints will be analysed via superiority testing using ANOVA, the Kruskal-Wallis test, logistic regression, or Fisher's exact test, as appropriate. Ethics and Dissemination: The study protocol has been approved by the Medical Devices Department of the Hungarian National Institute of Pharmacy and Nutrition, ensuring compliance with ethical standards as outlined in the Declaration of Helsinki. All investigators declare no conflicts of interest related to this study. The trial is registered in ClinicalTrials.gov under the ID: NCT04862052.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Personalized Medicine
Journal of Personalized Medicine Medicine-Medicine (miscellaneous)
CiteScore
4.10
自引率
0.00%
发文量
1878
审稿时长
11 weeks
期刊介绍: Journal of Personalized Medicine (JPM; ISSN 2075-4426) is an international, open access journal aimed at bringing all aspects of personalized medicine to one platform. JPM publishes cutting edge, innovative preclinical and translational scientific research and technologies related to personalized medicine (e.g., pharmacogenomics/proteomics, systems biology). JPM recognizes that personalized medicine—the assessment of genetic, environmental and host factors that cause variability of individuals—is a challenging, transdisciplinary topic that requires discussions from a range of experts. For a comprehensive perspective of personalized medicine, JPM aims to integrate expertise from the molecular and translational sciences, therapeutics and diagnostics, as well as discussions of regulatory, social, ethical and policy aspects. We provide a forum to bring together academic and clinical researchers, biotechnology, diagnostic and pharmaceutical companies, health professionals, regulatory and ethical experts, and government and regulatory authorities.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信