{"title":"Quantitative Evaluation of Debris Removal from NiTi Rotary Endodontic Instruments After Different Cleaning Procedures.","authors":"Luigi Generali, Paolo Generali, Pio Bertani, Francesco Cavani, Vittorio Checchi, Tommaso Filippini, Federica Veneri","doi":"10.3390/dj13020049","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> Endodontic instruments require thorough decontamination and sterilization before use and reuse to ensure the safety and success of treatments. However, standardized protocols are lacking. This study aimed to quantitatively assess the effectiveness of different cleaning protocols in removing debris from NiTi rotary file surfaces. <b>Methods:</b> Forty-eight new Mtwo NiTi rotary instruments (sizes 10/.04, 15/.05, 20/.06, and 25/.06) were randomly assigned to four groups (n = 12). A set of new sterile instruments (Group I) served as the negative control. After usage for primary endodontic treatment, instruments underwent different cleaning protocols: steam sterilization without cleaning (Group II); ultrasonic cleaning + steam sterilization (Group III); and manual cleaning with a scouring sponge + ultrasonic cleaning + steam sterilization (Group IV). Back-scattered scanning electron microscopy (SEM) micrographs of the apical, middle, and coronal sections were processed using Fiji software (version 2.14.0) to quantify debris as a percentage of the total selected area. <b>Results:</b> No significant differences were found among the three sections within each group, although higher debris amounts were observed from coronal to apical in Groups I and II. Group I had the least debris, while Group II showed the most, with statistically significant differences compared to other groups (<i>p</i> < 0.05). There was no significant difference between Groups III and IV, though Group IV showed notably less debris. <b>Conclusions:</b> The combination of mechanical, chemical, and ultrasonic cleaning proved most effective at removing debris from endodontic instruments. Current cleaning methods, however, remain insufficient for complete debris removal, highlighting the need for further research to standardize and improve cleaning and sterilization protocols or preferably use single-use/single-patient instruments.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"13 2","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11853741/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj13020049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Endodontic instruments require thorough decontamination and sterilization before use and reuse to ensure the safety and success of treatments. However, standardized protocols are lacking. This study aimed to quantitatively assess the effectiveness of different cleaning protocols in removing debris from NiTi rotary file surfaces. Methods: Forty-eight new Mtwo NiTi rotary instruments (sizes 10/.04, 15/.05, 20/.06, and 25/.06) were randomly assigned to four groups (n = 12). A set of new sterile instruments (Group I) served as the negative control. After usage for primary endodontic treatment, instruments underwent different cleaning protocols: steam sterilization without cleaning (Group II); ultrasonic cleaning + steam sterilization (Group III); and manual cleaning with a scouring sponge + ultrasonic cleaning + steam sterilization (Group IV). Back-scattered scanning electron microscopy (SEM) micrographs of the apical, middle, and coronal sections were processed using Fiji software (version 2.14.0) to quantify debris as a percentage of the total selected area. Results: No significant differences were found among the three sections within each group, although higher debris amounts were observed from coronal to apical in Groups I and II. Group I had the least debris, while Group II showed the most, with statistically significant differences compared to other groups (p < 0.05). There was no significant difference between Groups III and IV, though Group IV showed notably less debris. Conclusions: The combination of mechanical, chemical, and ultrasonic cleaning proved most effective at removing debris from endodontic instruments. Current cleaning methods, however, remain insufficient for complete debris removal, highlighting the need for further research to standardize and improve cleaning and sterilization protocols or preferably use single-use/single-patient instruments.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信