A multiplexed laser-scribed graphene immunosensor for simultaneous detection of adiponectin and leptin: A point-of-care solution for early insulin resistance diagnosis

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
Lavita Nuraviana Rizalputri , José Ilton de Oliveira Filho , Saptami Suresh Shetty , Eckaard le Roux , Abdullah Bukhamsin , Bandar Alshehri , Veerappan Mani , Khaled Nabil Salama
{"title":"A multiplexed laser-scribed graphene immunosensor for simultaneous detection of adiponectin and leptin: A point-of-care solution for early insulin resistance diagnosis","authors":"Lavita Nuraviana Rizalputri ,&nbsp;José Ilton de Oliveira Filho ,&nbsp;Saptami Suresh Shetty ,&nbsp;Eckaard le Roux ,&nbsp;Abdullah Bukhamsin ,&nbsp;Bandar Alshehri ,&nbsp;Veerappan Mani ,&nbsp;Khaled Nabil Salama","doi":"10.1016/j.snr.2025.100306","DOIUrl":null,"url":null,"abstract":"<div><div>The increasing prevalence of insulin resistance (IR) highlights the importance of early diagnosis and timely medical intervention. The ratio of adiponectin to leptin proteins (A/L) is believed to be a key indicator of IR, but the lack of adequate ways of tracking it prevents its clinical utilization. To that end, we have developed a laser-scribed graphene (LSG) based immunosensor capable of detecting adiponectin and leptin simultaneously. The sensors are decorated with gold nanostructure (AuNS) that are bio-functionalized with adiponectin and leptin antibodies via EDC/NHS covalent chemistry. We demonstrate that the immunosensor is suitable for clinical utilization, with a detection limit of 0.59 μg/mL for adiponectin and 0.18 ng/mL for leptin. Furthermore, the multiplexed nature of the assay allows for IR assessments at reduced sample volume whilst not compromising accuracy. Lastly, we validate the applicability of the immunosensor for point-of-care (PoC) settings by integrating with a customized miniaturized potentiostat connected to a smartphone application. The resulting device can be used for the facile quantification of A/L at clinically relevant accuracy, facilitating faster IR assessment relative to conventional methods that rely on independent measurements of the two biomarkers.</div></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"9 ","pages":"Article 100306"},"PeriodicalIF":6.5000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053925000256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing prevalence of insulin resistance (IR) highlights the importance of early diagnosis and timely medical intervention. The ratio of adiponectin to leptin proteins (A/L) is believed to be a key indicator of IR, but the lack of adequate ways of tracking it prevents its clinical utilization. To that end, we have developed a laser-scribed graphene (LSG) based immunosensor capable of detecting adiponectin and leptin simultaneously. The sensors are decorated with gold nanostructure (AuNS) that are bio-functionalized with adiponectin and leptin antibodies via EDC/NHS covalent chemistry. We demonstrate that the immunosensor is suitable for clinical utilization, with a detection limit of 0.59 μg/mL for adiponectin and 0.18 ng/mL for leptin. Furthermore, the multiplexed nature of the assay allows for IR assessments at reduced sample volume whilst not compromising accuracy. Lastly, we validate the applicability of the immunosensor for point-of-care (PoC) settings by integrating with a customized miniaturized potentiostat connected to a smartphone application. The resulting device can be used for the facile quantification of A/L at clinically relevant accuracy, facilitating faster IR assessment relative to conventional methods that rely on independent measurements of the two biomarkers.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信