Use of an off the Shelf Inner Branch Thoraco-abdominal Endograft for the Treatment of Juxtarenal and Pararenal Aortic Aneurysms.

IF 5.7 1区 医学 Q1 PERIPHERAL VASCULAR DISEASE
Francesco Squizzato, Michele Piazza, Giacomo Isernia, Giovanni Pratesi, Emanuele Gatta, Michelangelo Ferri, Yamume Tshomba, Roberto Gattuso, Gian Franco Veraldi, Michele Antonello
{"title":"Use of an off the Shelf Inner Branch Thoraco-abdominal Endograft for the Treatment of Juxtarenal and Pararenal Aortic Aneurysms.","authors":"Francesco Squizzato, Michele Piazza, Giacomo Isernia, Giovanni Pratesi, Emanuele Gatta, Michelangelo Ferri, Yamume Tshomba, Roberto Gattuso, Gian Franco Veraldi, Michele Antonello","doi":"10.1016/j.ejvs.2025.02.030","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate outcomes obtained using an off the shelf pre-loaded inner branched endograft (E-nside) for the treatment of juxtarenal and pararenal aortic aneurysms (J-PRAA).</p><p><strong>Methods: </strong>Data from a multicentre registry (INBREED), including patients treated with E-nside endograft, were prospectively collected and analysed. Patients treated for J-PRAA were included. Pre-operative clinical and anatomical characteristics, procedural data, 30 day, and one year outcomes were recorded. Endpoints were technical success, 30 day mortality, major adverse events (MAE), and one year freedom from target vessel instability.</p><p><strong>Results: </strong>Of 185 consecutive treated patients, 47 (25.0%) had a J-PRAA (juxtarenal n = 10, 21.0%; pararenal n = 37, 79.0%) and were included; 183 target vessels were incorporated through an inner branch. Procedural setting was emergent or urgent in 18 patients (38.0%) owing to a contained aortic rupture (n = 2, 4.0%), symptomatic aneurysm (n = 4, 9.0%), or aneurysm > 70 mm (n = 12, 87.0%). Mean length of aortic coverage above the coeliac trunk was 116 ± 7 mm. Technical success was 100%, and 30 day mortality was 4.0% (n = 2 urgent cases). The thirty day cumulative MAE rate was 26.0% (n = 12): two stroke (4.0%); seven spinal cord ischaemia (15.0%); six in an elective setting (20.0%) and one in an urgent setting (6.0%), and five leading to permanent paraplegia/paraparesis (10.0%). Freedom from target vessel instability was 99.0% after 30 days and 97.0 ± 3.0% after one year.</p><p><strong>Conclusion: </strong>Use of an off the shelf inner branched device for treating J-PRAA was feasible in urgent and elective settings, with high technical success and satisfactory target vessel stability at one year. In the treatment of J-PRAA, stroke and spinal cord ischaemia may be associated with arm access and increased aortic coverage that the design brings.</p>","PeriodicalId":55160,"journal":{"name":"European Journal of Vascular and Endovascular Surgery","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Vascular and Endovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ejvs.2025.02.030","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate outcomes obtained using an off the shelf pre-loaded inner branched endograft (E-nside) for the treatment of juxtarenal and pararenal aortic aneurysms (J-PRAA).

Methods: Data from a multicentre registry (INBREED), including patients treated with E-nside endograft, were prospectively collected and analysed. Patients treated for J-PRAA were included. Pre-operative clinical and anatomical characteristics, procedural data, 30 day, and one year outcomes were recorded. Endpoints were technical success, 30 day mortality, major adverse events (MAE), and one year freedom from target vessel instability.

Results: Of 185 consecutive treated patients, 47 (25.0%) had a J-PRAA (juxtarenal n = 10, 21.0%; pararenal n = 37, 79.0%) and were included; 183 target vessels were incorporated through an inner branch. Procedural setting was emergent or urgent in 18 patients (38.0%) owing to a contained aortic rupture (n = 2, 4.0%), symptomatic aneurysm (n = 4, 9.0%), or aneurysm > 70 mm (n = 12, 87.0%). Mean length of aortic coverage above the coeliac trunk was 116 ± 7 mm. Technical success was 100%, and 30 day mortality was 4.0% (n = 2 urgent cases). The thirty day cumulative MAE rate was 26.0% (n = 12): two stroke (4.0%); seven spinal cord ischaemia (15.0%); six in an elective setting (20.0%) and one in an urgent setting (6.0%), and five leading to permanent paraplegia/paraparesis (10.0%). Freedom from target vessel instability was 99.0% after 30 days and 97.0 ± 3.0% after one year.

Conclusion: Use of an off the shelf inner branched device for treating J-PRAA was feasible in urgent and elective settings, with high technical success and satisfactory target vessel stability at one year. In the treatment of J-PRAA, stroke and spinal cord ischaemia may be associated with arm access and increased aortic coverage that the design brings.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
15.80%
发文量
471
审稿时长
66 days
期刊介绍: The European Journal of Vascular and Endovascular Surgery is aimed primarily at vascular surgeons dealing with patients with arterial, venous and lymphatic diseases. Contributions are included on the diagnosis, investigation and management of these vascular disorders. Papers that consider the technical aspects of vascular surgery are encouraged, and the journal includes invited state-of-the-art articles. Reflecting the increasing importance of endovascular techniques in the management of vascular diseases and the value of closer collaboration between the vascular surgeon and the vascular radiologist, the journal has now extended its scope to encompass the growing number of contributions from this exciting field. Articles describing endovascular method and their critical evaluation are included, as well as reports on the emerging technology associated with this field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信