Pattipong Wisanpitayakorn, Narumol Jariyasopit, Kassaporn Duangkumpha, Jun Xian Goh, Martin E Palmer, Yongyut Sirivatanauksorn, Sakda Khoomrung
{"title":"Multi-Pass Arrival Time Correction in Cyclic Ion Mobility Mass Spectrometry for Imaging and Shotgun Lipidomics.","authors":"Pattipong Wisanpitayakorn, Narumol Jariyasopit, Kassaporn Duangkumpha, Jun Xian Goh, Martin E Palmer, Yongyut Sirivatanauksorn, Sakda Khoomrung","doi":"10.1021/acsmeasuresciau.4c00077","DOIUrl":null,"url":null,"abstract":"<p><p>Direct-infusion mass spectrometry (DI-MS) and mass spectrometry imaging (MSI) are powerful techniques for lipidomics research. However, annotating isomeric and isobaric lipids with these methods is challenging due to the absence of chromatographic separation. Recently, cyclic ion mobility mass spectrometry (cIM-MS) has been proposed to overcome this limitation. However, fluctuations in room conditions can affect ion mobility multipass arrival times, potentially reducing annotation confidence. In this study, we developed a multipass arrival time correction method that proved effective across various dates, room temperatures, ion mobility settings, and laboratories using mixtures of reference standards. We observed slight variations in the linear correction lines between lipid and nonlipid molecules, underscoring the importance of choosing appropriate reference molecules. Based on these results, we demonstrated that an accurate multipass arrival time database can be constructed from corrected <i>t</i> <sub>0</sub> and <i>t</i> <sub>p</sub> for interlaboratory use and can effectively identify isomeric lipids in MSI using only a single measurement. This approach significantly simplifies the identification process compared to determining multipass collision cross-section, which requires multiple measurements that are both sample- and time-intensive for MSI. Additionally, we validated our multipass drift time correction method in shotgun lipidomics analyses of human and mouse serum samples and observed no matrix effect for the analysis. Despite variations in dates, room temperatures, instruments, and ion mobility settings, our approach reduced the mean drift time differences from over 2% to below 0.2%.</p>","PeriodicalId":29800,"journal":{"name":"ACS Measurement Science Au","volume":"5 1","pages":"109-119"},"PeriodicalIF":4.6000,"publicationDate":"2024-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11843504/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Measurement Science Au","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1021/acsmeasuresciau.4c00077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/19 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Direct-infusion mass spectrometry (DI-MS) and mass spectrometry imaging (MSI) are powerful techniques for lipidomics research. However, annotating isomeric and isobaric lipids with these methods is challenging due to the absence of chromatographic separation. Recently, cyclic ion mobility mass spectrometry (cIM-MS) has been proposed to overcome this limitation. However, fluctuations in room conditions can affect ion mobility multipass arrival times, potentially reducing annotation confidence. In this study, we developed a multipass arrival time correction method that proved effective across various dates, room temperatures, ion mobility settings, and laboratories using mixtures of reference standards. We observed slight variations in the linear correction lines between lipid and nonlipid molecules, underscoring the importance of choosing appropriate reference molecules. Based on these results, we demonstrated that an accurate multipass arrival time database can be constructed from corrected t0 and tp for interlaboratory use and can effectively identify isomeric lipids in MSI using only a single measurement. This approach significantly simplifies the identification process compared to determining multipass collision cross-section, which requires multiple measurements that are both sample- and time-intensive for MSI. Additionally, we validated our multipass drift time correction method in shotgun lipidomics analyses of human and mouse serum samples and observed no matrix effect for the analysis. Despite variations in dates, room temperatures, instruments, and ion mobility settings, our approach reduced the mean drift time differences from over 2% to below 0.2%.
期刊介绍:
ACS Measurement Science Au is an open access journal that publishes experimental computational or theoretical research in all areas of chemical measurement science. Short letters comprehensive articles reviews and perspectives are welcome on topics that report on any phase of analytical operations including sampling measurement and data analysis. This includes:Chemical Reactions and SelectivityChemometrics and Data ProcessingElectrochemistryElemental and Molecular CharacterizationImagingInstrumentationMass SpectrometryMicroscale and Nanoscale systemsOmics (Genomics Proteomics Metabonomics Metabolomics and Bioinformatics)Sensors and Sensing (Biosensors Chemical Sensors Gas Sensors Intracellular Sensors Single-Molecule Sensors Cell Chips Arrays Microfluidic Devices)SeparationsSpectroscopySurface analysisPapers dealing with established methods need to offer a significantly improved original application of the method.