{"title":"A Case of Laparoscopic Resection of Gastric Cancer Using Novel Laparoscopic Fluorescence Spectrum System and Near-Infrared Fluorescent Clips.","authors":"Shion Uemura, Yuma Ebihara, Kazuya Konishi, Satoshi Hirano","doi":"10.70352/scrj.cr.24-0028","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In laparoscopic gastrectomy, accurate marking of the lesion site is essential in determining the resection line of the stomach, owing to the lack of haptics and the direct link between negative pathological margins and prognosis. Intraoperative endoscopy may require personnel and prolong the operation time, whereas preoperative endoscopic tattooing using India ink faces problems related to the spread of ink and visibility. ZEOCLIP FS (Zeon Medical, Tokyo, Japan) is a clip made of fluorescent resin, covered by insurance since March 2019. It can be visualized from the serosal side using a near-infrared scope; however, its weak fluorescence intensity often poses viewing difficulties. Lumifinder (ADVANTEST, Tokyo, Japan) is a laparoscopic fluorescence spectrum system available for clinical use since February 2023. It can measure fluorescence intensity using a near-infrared laser and detect weak fluorescent signals. We report a case of gastric cancer in which the location of the lesion was confirmed intraoperatively using ZEOCLIP FS and Lumifinder.</p><p><strong>Case presentation: </strong>A man in his 80s was diagnosed with gastric cancer following an examination for anemia. Two lesions were found: a 0-IIc type (cT1) at the lesser curvature of the gastric angle and a type 1 tumor (cT2) at the anterior wall of the upper gastric body. The preoperative assessment indicated no lymph node or distant metastasis. The tumor was diagnosed as cStage I and laparoscopic distal gastrectomy was planned. Two ZEOCLIP FS clips were placed on the oral side of the tumor on the anterior wall of the upper gastric body on the day before surgery. During surgery, fluorescent signals from the clips were detected using Lumifinder, enabling easy confirmation of the lesion location and determination of the gastric resection line.</p><p><strong>Conclusions: </strong>The combined use of ZEOCLIP FS and Lumifinder was a useful new method for identifying the appropriate resection line of the stomach. We plan to evaluate this method further in additional cases to enhance the detection efficacy.</p>","PeriodicalId":22096,"journal":{"name":"Surgical Case Reports","volume":"11 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11842931/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70352/scrj.cr.24-0028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: In laparoscopic gastrectomy, accurate marking of the lesion site is essential in determining the resection line of the stomach, owing to the lack of haptics and the direct link between negative pathological margins and prognosis. Intraoperative endoscopy may require personnel and prolong the operation time, whereas preoperative endoscopic tattooing using India ink faces problems related to the spread of ink and visibility. ZEOCLIP FS (Zeon Medical, Tokyo, Japan) is a clip made of fluorescent resin, covered by insurance since March 2019. It can be visualized from the serosal side using a near-infrared scope; however, its weak fluorescence intensity often poses viewing difficulties. Lumifinder (ADVANTEST, Tokyo, Japan) is a laparoscopic fluorescence spectrum system available for clinical use since February 2023. It can measure fluorescence intensity using a near-infrared laser and detect weak fluorescent signals. We report a case of gastric cancer in which the location of the lesion was confirmed intraoperatively using ZEOCLIP FS and Lumifinder.

Case presentation: A man in his 80s was diagnosed with gastric cancer following an examination for anemia. Two lesions were found: a 0-IIc type (cT1) at the lesser curvature of the gastric angle and a type 1 tumor (cT2) at the anterior wall of the upper gastric body. The preoperative assessment indicated no lymph node or distant metastasis. The tumor was diagnosed as cStage I and laparoscopic distal gastrectomy was planned. Two ZEOCLIP FS clips were placed on the oral side of the tumor on the anterior wall of the upper gastric body on the day before surgery. During surgery, fluorescent signals from the clips were detected using Lumifinder, enabling easy confirmation of the lesion location and determination of the gastric resection line.

Conclusions: The combined use of ZEOCLIP FS and Lumifinder was a useful new method for identifying the appropriate resection line of the stomach. We plan to evaluate this method further in additional cases to enhance the detection efficacy.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
218
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信