Roel Hoek, Ruben W de Winter, Rens T Peters, Yvemarie B O Somsen, Pepijn A van Diemen, Ruurt A Jukema, Jos W Twisk, Niels J Verouden, Alexander W den Hartog, Pieter G Raijmakers, Alexander Nap, Ibrahim Danad, Paul Knaapen
{"title":"Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts.","authors":"Roel Hoek, Ruben W de Winter, Rens T Peters, Yvemarie B O Somsen, Pepijn A van Diemen, Ruurt A Jukema, Jos W Twisk, Niels J Verouden, Alexander W den Hartog, Pieter G Raijmakers, Alexander Nap, Ibrahim Danad, Paul Knaapen","doi":"10.1002/ccd.31467","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Revascularization decision-making for saphenous vein grafts (SVGs) relies on angiographic lesion severity estimation, as studies on fractional flow reserve (FFR) for detecting ischemia in SVGs are scarce.</p><p><strong>Aims: </strong>To compare FFR and quantitative coronary angiography (QCA) of SVGs against myocardial perfusion imaging (MPI) and to establish an optimal FFR threshold for SVGs.</p><p><strong>Methods: </strong>This cross-sectional registry study included symptomatic patients with prior coronary artery bypass grafting who underwent single-photon emission computed tomography, positron emission tomography, or stress perfusion cardiac magnetic resonance imaging and had FFR measurements of ≥ 1 SVGs. We matched the myocardial territory supplied by the SVGs to ischemia on MPI. The optimal FFR threshold for SVGs was determined using the Youden index. Diagnostic performance measures were calculated and compared for FFR (0.80 and the optimal threshold) and for QCA (diameter stenosis ≥ 50%).</p><p><strong>Results: </strong>This study included 80 patients (mean age 73 ± 7 years, 68 [85%] male) with 94 SVGs, of which 38 (40%) supplied ischemic myocardium. Areas under the curve between FFR and QCA were comparable (0.73 vs. 0.65, p = 0.181). The optimal cutoff value of FFR was 0.94. FFR ≤ 0.94 showed higher sensitivity (63%) and negative predictive value (75%) compared to FFR ≤ 0.80 (32% [p < 0.001] and 64% [p = 0.007]) and QCA (37% [p = 0.002] and 65% [p = 0.021]), but with lower specificity (75%) than FFR ≤ 0.80 (84%, p = 0.021). Positive predictive value and overall accuracy were similar across all methods.</p><p><strong>Conclusions: </strong>FFR and QCA had comparable moderate diagnostic performance for detecting SVG failure determined by MPI. The optimal FFR cutoff in SVGs is higher than 0.80, resulting in higher sensitivity and negative predictive value compared to FFR ≤ 0.80 and QCA, at the expense of reduced specificity.</p>","PeriodicalId":9650,"journal":{"name":"Catheterization and Cardiovascular Interventions","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ccd.31467","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Revascularization decision-making for saphenous vein grafts (SVGs) relies on angiographic lesion severity estimation, as studies on fractional flow reserve (FFR) for detecting ischemia in SVGs are scarce.
Aims: To compare FFR and quantitative coronary angiography (QCA) of SVGs against myocardial perfusion imaging (MPI) and to establish an optimal FFR threshold for SVGs.
Methods: This cross-sectional registry study included symptomatic patients with prior coronary artery bypass grafting who underwent single-photon emission computed tomography, positron emission tomography, or stress perfusion cardiac magnetic resonance imaging and had FFR measurements of ≥ 1 SVGs. We matched the myocardial territory supplied by the SVGs to ischemia on MPI. The optimal FFR threshold for SVGs was determined using the Youden index. Diagnostic performance measures were calculated and compared for FFR (0.80 and the optimal threshold) and for QCA (diameter stenosis ≥ 50%).
Results: This study included 80 patients (mean age 73 ± 7 years, 68 [85%] male) with 94 SVGs, of which 38 (40%) supplied ischemic myocardium. Areas under the curve between FFR and QCA were comparable (0.73 vs. 0.65, p = 0.181). The optimal cutoff value of FFR was 0.94. FFR ≤ 0.94 showed higher sensitivity (63%) and negative predictive value (75%) compared to FFR ≤ 0.80 (32% [p < 0.001] and 64% [p = 0.007]) and QCA (37% [p = 0.002] and 65% [p = 0.021]), but with lower specificity (75%) than FFR ≤ 0.80 (84%, p = 0.021). Positive predictive value and overall accuracy were similar across all methods.
Conclusions: FFR and QCA had comparable moderate diagnostic performance for detecting SVG failure determined by MPI. The optimal FFR cutoff in SVGs is higher than 0.80, resulting in higher sensitivity and negative predictive value compared to FFR ≤ 0.80 and QCA, at the expense of reduced specificity.
期刊介绍:
Catheterization and Cardiovascular Interventions is an international journal covering the broad field of cardiovascular diseases. Subject material includes basic and clinical information that is derived from or related to invasive and interventional coronary or peripheral vascular techniques. The journal focuses on material that will be of immediate practical value to physicians providing patient care in the clinical laboratory setting. To accomplish this, the journal publishes Preliminary Reports and Work In Progress articles that complement the traditional Original Studies, Case Reports, and Comprehensive Reviews. Perspective and insight concerning controversial subjects and evolving technologies are provided regularly through Editorial Commentaries furnished by members of the Editorial Board and other experts. Articles are subject to double-blind peer review and complete editorial evaluation prior to any decision regarding acceptability.