Synergistically improved electrochemical performance by the assembly of nanosized iron manganese oxide catalyst for the detection of Seleno-L-methionine amino acid
{"title":"Synergistically improved electrochemical performance by the assembly of nanosized iron manganese oxide catalyst for the detection of Seleno-L-methionine amino acid","authors":"Yamunadevi Kandeepan , Tse-Wei Chen , Sivaprakash Sengodan , Jaysan Yu , Shen-Ming Chen","doi":"10.1016/j.jtice.2025.106012","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Seleno-<span>L</span>-methionine (L-Se-Met) is an organic selenium compound that serves as an essential trace element known for its potent antioxidant properties. It provides selenium in dietary supplements to support thyroid health, immune function, and antioxidant defense. However, an excessive consumption of <span>L</span>-Se-Met can lead to selenium toxicity and detrimental side effects on human health. Therefore, the development of a fast and sensitive method is needed for the monitoring of <span>L</span>- Se-Met.</div></div><div><h3>Methods</h3><div>Herein, a simple and cost-effective electrode based on iron manganese oxide (Fe<sub>2</sub>O<sub>3</sub>/Mn<sub>3</sub>O<sub>4</sub>) catalyst, which could be actuated by a electrochemical sensing platform has been designed. Fe<sub>2</sub>O<sub>3</sub>/Mn<sub>3</sub>O<sub>4</sub> were successfully prepared by the hydrothermal technique. The proposed Fe<sub>2</sub>O<sub>3</sub>/Mn<sub>3</sub>O<sub>4</sub> catalyst was used to modify the glassy carbon electrode (GCE), and the modified electrode was deployed to sense <span>L</span>- Se-Met. The electrochemical characteristics of the fabricated sensor were then studied through cyclic voltammetry (CV) and differential pulse voltammetry (DPV).</div></div><div><h3>Significant findings</h3><div>The sensor resulted in a oxidation peak current response that covered a broad linear range from 3.92–992.29 ng/L and had a low detection limit (LOD) of 4.59 ng/L, a limit of quantification (LOQ) of 13.92 ng/L and a sensitivity of 0.0031 µA/µM cm<sup>2</sup> with outstanding performance. The developed sensor determined satisfactory recovery results for detecting <span>L</span>-Se-Met in samples of broccoli, green bean, green gram, mushroom, onion, red gram and human blood serum using the DPV method.</div></div>","PeriodicalId":381,"journal":{"name":"Journal of the Taiwan Institute of Chemical Engineers","volume":"170 ","pages":"Article 106012"},"PeriodicalIF":5.5000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Taiwan Institute of Chemical Engineers","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1876107025000653","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Seleno-L-methionine (L-Se-Met) is an organic selenium compound that serves as an essential trace element known for its potent antioxidant properties. It provides selenium in dietary supplements to support thyroid health, immune function, and antioxidant defense. However, an excessive consumption of L-Se-Met can lead to selenium toxicity and detrimental side effects on human health. Therefore, the development of a fast and sensitive method is needed for the monitoring of L- Se-Met.
Methods
Herein, a simple and cost-effective electrode based on iron manganese oxide (Fe2O3/Mn3O4) catalyst, which could be actuated by a electrochemical sensing platform has been designed. Fe2O3/Mn3O4 were successfully prepared by the hydrothermal technique. The proposed Fe2O3/Mn3O4 catalyst was used to modify the glassy carbon electrode (GCE), and the modified electrode was deployed to sense L- Se-Met. The electrochemical characteristics of the fabricated sensor were then studied through cyclic voltammetry (CV) and differential pulse voltammetry (DPV).
Significant findings
The sensor resulted in a oxidation peak current response that covered a broad linear range from 3.92–992.29 ng/L and had a low detection limit (LOD) of 4.59 ng/L, a limit of quantification (LOQ) of 13.92 ng/L and a sensitivity of 0.0031 µA/µM cm2 with outstanding performance. The developed sensor determined satisfactory recovery results for detecting L-Se-Met in samples of broccoli, green bean, green gram, mushroom, onion, red gram and human blood serum using the DPV method.
期刊介绍:
Journal of the Taiwan Institute of Chemical Engineers (formerly known as Journal of the Chinese Institute of Chemical Engineers) publishes original works, from fundamental principles to practical applications, in the broad field of chemical engineering with special focus on three aspects: Chemical and Biomolecular Science and Technology, Energy and Environmental Science and Technology, and Materials Science and Technology. Authors should choose for their manuscript an appropriate aspect section and a few related classifications when submitting to the journal online.