Laboratory experimental analysis of crystalline silicon photovoltaic module degradation after operating over 6 years: A case study in Ghana

IF 6 2区 工程技术 Q2 ENERGY & FUELS
Qingfa MENG , Honglie SHEN , Jinjie ZHENG , Xuemei LI
{"title":"Laboratory experimental analysis of crystalline silicon photovoltaic module degradation after operating over 6 years: A case study in Ghana","authors":"Qingfa MENG ,&nbsp;Honglie SHEN ,&nbsp;Jinjie ZHENG ,&nbsp;Xuemei LI","doi":"10.1016/j.solener.2025.113379","DOIUrl":null,"url":null,"abstract":"<div><div>This paper systematically analyzes and evaluates the performance of photovoltaic (PV) modules after six years of outdoor exposure in Winneba, Ghana, under a hot and humid climate. Unlike conventional field tests, all data were obtained through rigorous laboratory testing conducted on the PV modules and their materials in accordance with IEC 61215 standards to investigate the causes of power degradation. The results indicated an average power degradation of 35.36 %, equivalent to an annual degradation rate of 5.89 %. Although most modules met the wet insulation test criteria specified by IEC 61215, they exhibited potential safety risks for future field operations due to wet insulation values approaching the standard threshold of 24.5 MΩ. The primary cause of power degradation was identified as potential-induced degradation (PID), with modules experiencing power losses of 44.60 % and 99.57 % under PID testing with a 1000 V negative voltage stress. Electroluminescence (EL) images showing dark edges provided strong evidence supporting the presence of PID. Additionally, poor peel strength test results suggested a risk of delamination, which could be attributed to ion migration during the PID process. Four out of five tested module gel contents were comparable to those of typical unexposed ethylene–vinyl acetate (EVA), and two modules still met the standard requirements even after exposure to damp heat (DH1000), indicating that EVA degradation may not be the primary cause of power loss. The water vapor transmittance rate (WVTR) of the module backsheets, after six years of outdoor exposure, continued to meet the requirements of the Chinese National Standard, further suggesting that moisture ingress may not be a significant contributor to power degradation. This study represents a valuable effort to assess the long-term performance of field-exposed PV modules using accelerated aging tests conducted according to IEC 61215 standards.</div></div>","PeriodicalId":428,"journal":{"name":"Solar Energy","volume":"290 ","pages":"Article 113379"},"PeriodicalIF":6.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Solar Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0038092X25001422","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

This paper systematically analyzes and evaluates the performance of photovoltaic (PV) modules after six years of outdoor exposure in Winneba, Ghana, under a hot and humid climate. Unlike conventional field tests, all data were obtained through rigorous laboratory testing conducted on the PV modules and their materials in accordance with IEC 61215 standards to investigate the causes of power degradation. The results indicated an average power degradation of 35.36 %, equivalent to an annual degradation rate of 5.89 %. Although most modules met the wet insulation test criteria specified by IEC 61215, they exhibited potential safety risks for future field operations due to wet insulation values approaching the standard threshold of 24.5 MΩ. The primary cause of power degradation was identified as potential-induced degradation (PID), with modules experiencing power losses of 44.60 % and 99.57 % under PID testing with a 1000 V negative voltage stress. Electroluminescence (EL) images showing dark edges provided strong evidence supporting the presence of PID. Additionally, poor peel strength test results suggested a risk of delamination, which could be attributed to ion migration during the PID process. Four out of five tested module gel contents were comparable to those of typical unexposed ethylene–vinyl acetate (EVA), and two modules still met the standard requirements even after exposure to damp heat (DH1000), indicating that EVA degradation may not be the primary cause of power loss. The water vapor transmittance rate (WVTR) of the module backsheets, after six years of outdoor exposure, continued to meet the requirements of the Chinese National Standard, further suggesting that moisture ingress may not be a significant contributor to power degradation. This study represents a valuable effort to assess the long-term performance of field-exposed PV modules using accelerated aging tests conducted according to IEC 61215 standards.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Solar Energy
Solar Energy 工程技术-能源与燃料
CiteScore
13.90
自引率
9.00%
发文量
0
审稿时长
47 days
期刊介绍: Solar Energy welcomes manuscripts presenting information not previously published in journals on any aspect of solar energy research, development, application, measurement or policy. The term "solar energy" in this context includes the indirect uses such as wind energy and biomass
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信